Introduction Bifurcation aneurysms represent an ongoing endovascular challenge with a variety of techniques and devices designed to address them. We present our multicenter series of the pCONUS2 and pCONUS2 HPC devices when treating bifurcation aneurysms. Methods We performed a retrospective review of our prospectively maintained databases at 3 tertiary neurointerventional centers to identify all patients who underwent coil embolization with the pCONUS2 or pCONUS2 HPC device between February 2015 and August 2021. We recorded baseline demographics, aneurysm data, complications, immediate and delayed angiographic results. Results We identified 55 patients with 56 aneurysms, median age 63 years (range 42-78 years), 67.3% female (n = 37). The commonest aneurysm location was the MCA bifurcation (n = 40, 71.4%). Average dome height was 8.9 +/- 4.2 mm (range 3.2-21.5 mm), average neck width 6.4 +/- 2.5 mm (range 2.6-14 mm), and average aspect ratio 1.3 +/- 0.6 (range 0.5-3.3). The pCONUS2 was used in 64.3% and the pCONUS2 HPC in 35.7%. The procedural technical success rate was 98.2%. Intraoperative complications occurred in 5 cases (8.9%), 4 of which were related to the coils with partial thrombus formation on the pCONUS2 HPC seen in 1 case that was resolved with heparin. In relation to the procedure and treatment of the aneurysm the overall permanent morbidity was 1.8% (n = 1/55) and mortality 0%. Delayed angiographic follow-up (48 aneurysms) at median 12 months postprocedure (range 3-36 months) demonstrated adequate occlusion of 83.4% of aneurysms. Conclusion The pCONUS2 and pCONUS2 HPC devices carry a high technical success rate, low complication and retreatment rate, and good rates of adequate occlusion. Larger prospective confirmatory studies are required.

© 2022. The Author(s).

Datos de la publicación

ISSN/ISSNe:
1869-1439, 1869-1447

Clinical Neuroradiology  SPRINGER HEIDELBERG

Tipo:
Article
Páginas:
129-136
PubMed:
35819477
Enlace a otro recurso:
www.scopus.com
Factor de Impacto:
0,818 SCImago ℠
Cuartil:
Q2 SCImago ℠

Citas Recibidas en Web of Science: 5

Citas Recibidas en Scopus: 6

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Aneurysm; Bifurcation aneurysm; PCONUS 2; PCONUS2 HPC; Wide neck

Cita

Compartir