Background Quality assurance (QA) and quality control (QC) are two quality management processes that are integral to the success of metabolomics including their application for the acquisition of high quality data in any high-throughput analytical chemistry laboratory. QA defines all the planned and systematic activities implemented before samples are collected, to provide confidence that a subsequent analytical process will fulfil predetermined requirements for quality. QC can be defined as the operational techniques and activities used to measure and report these quality requirements after data acquisition. Aim of review This tutorial review will guide the reader through the use of system suitability and QC samples, why these samples should be applied and how the quality of data can be reported. Key scientific concepts of review System suitability samples are applied to assess the operation and lack of contamination of the analytical platform prior to sample analysis. Isotopically-labelled internal standards are applied to assess system stability for each sample analysed. Pooled QC samples are applied to condition the analytical platform, perform intra-study reproducibility measurements (QC) and to correct mathematically for systematic errors. Standard reference materials and long-term reference QC samples are applied for inter-study and inter-laboratory assessment of data.
Datos de la publicación
- ISSN/ISSNe:
- 1573-3882, 1573-3890
- Tipo:
- Review
- Páginas:
- 72-72
- Factor de Impacto:
- 1,060 SCImago ℠
- Cuartil:
- Q1 SCImago ℠
METABOLOMICS SPRINGER
Citas Recibidas en Web of Science: 420
Documentos
- No hay documentos
Filiaciones
Keywords
- Quality assurance (QA); Quality control (QC); System suitability samples; Pooled QC samples; Standard reference materials (SRMs); Long-term reference (LTR) QC samples
Proyectos asociados
UTILIDAD DEL TRATAMIENTO TOCOLITICO DE MANTENIMIENTO EN EL MANEJO DE LA AMENAZA DE PARTO PREMATURO (APP)
Investigador Principal: MÁXIMO VENTO TORRES
EC11-246 . 2012
MULTICENTER, RANDOMIZED, BLINDED CLINICAL STUDY COMPARING EARLY USE OF TOTAL BODY MODERATE HYPOTHERMIA PLUS TOPIRAMATE OR PLACEBO IN ASPHYXIATED NEWBORN INFANTS EVOLVING TO MODERATE-TO-SEVERE HYPOXIC ISCHEMIC ENCEPHALOPATHY
Investigador Principal: MÁXIMO VENTO TORRES
EC11-244 . INSTITUTO DE SALUD CARLOS III; FUNDACIÓN PARA LA INVESTIGACIÓN DEL HOSPITAL UNIVERSITARIO LA FE DE LA COMUNIDAD VALENCIANA . 2012
EFECTO DE LA MODULACION DEL FACTOR INDUCIBLE POR HIPOXIA (HIF) SOBRE LA DEGENERACION RETINIANA EN RETINOSIS PIGMENTARIA
Investigador Principal: REGINA RODRIGO NICOLÁS
PI12/00481 . INSTITUTO DE SALUD CARLOS III; FUNDACIÓN PARA LA INVESTIGACIÓN DEL HOSPITAL UNIVERSITARIO LA FE DE LA COMUNIDAD VALENCIANA . 2013
RED DE SALUD MATERNO INFANTIL Y DEL DESARROLLO
Investigador Principal: MÁXIMO VENTO TORRES
RD12/0026/0012 . INSTITUTO DE SALUD CARLOS III; FUNDACIÓN PARA LA INVESTIGACIÓN DEL HOSPITAL UNIVERSITARIO LA FE DE LA COMUNIDAD VALENCIANA . 2013
DAÑO OXIDATIVO Y METILACIÓN DEL ADN Y ACTIVIDAD DE LAS ENZIMAS REPARADORAS Y SU FRECUENCIA MUTAGÉNICA EN PREMATUROS SEGÚN LA CARGA DE OXÍGENO RECIBIDA EN LA REANIMACIÓN
Investigador Principal: MÁXIMO VENTO TORRES
PI14/00443 . INSTITUTO DE SALUD CARLOS III . 2015
ALBINO. EFFECT OF ALLOPURINOL IN ADDITION TO HYPOTHERMIA FOR HYPOXIC-ISCHEMIC BRAIN INJURY ON NEUROCOGNITIVE OUTCOME.
Investigador Principal: MÁXIMO VENTO TORRES
667224 . COMISION EUROPEA . 2016
MINIMAL INVASIVE BIOMARKERS FOR THE PERSONALIZED TREATMENT OF NEONATAL HYPOXIC-ISCHEMIC ENCEPHALOPATHY (HIE). (CONTRATO)
Investigador Principal: JULIA KULIGOWSKI
MS16/00034 . INSTITUTO DE SALUD CARLOS III; FUNDACIÓN PARA LA INVESTIGACIÓN DEL HOSPITAL UNIVERSITARIO LA FE DE LA COMUNIDAD VALENCIANA . 2017
RED DE SALUD MATERNO-INFANTIL Y DEL DESARROLLO.
Investigador Principal: MÁXIMO VENTO TORRES
RD16/0022/0001 . INSTITUTO DE SALUD CARLOS III . 2017
BIOMARCADORES MÍNIMAMENTE INVASIVOS PARA UN TRATAMIENTO PERSONALIZADO DE LA ENCEFALOPATÍA HIPÓXICO-ISQUÉMICA NEONATAL.
Investigador Principal: JULIA KULIGOWSKI
PI17/00127 . INSTITUTO DE SALUD CARLOS III . 2018
MINIMAL INVASIVE BIOMARKERS FOR THE PERSONALIZED TREATMENT OF NEONATAL HYPOXIC-ISCHEMIC ENCEPHALOPATHY (HIE). (PROYECTO)
Investigador Principal: JULIA KULIGOWSKI
CP16/00034 . INSTITUTO DE SALUD CARLOS III . 2017
ENSAYO CLÍNICO MULTICÉNTRICO, ALEATORIZADO, DOBLE CIEGO Y CONTROLADO POR PLACEBO, COMPARANDO EL USO DE LA HIPOTERMIA CORPORAL TOTAL MODERADA PRECOZ CON TOPIRAMATO O CON PLACEBO EN RECIÉN NACIDOS ASFIXIADOS EVOLUCIONANDO A ENCEFALOPATÍA HIPÓXICO ISQUÉMICA MODERADA A SEVERA.
Investigador Principal: MÁXIMO VENTO TORRES
1645-CI-058 (HYPOTOP) . 2013
Cita
Broadhurst D,Goodacre R,Reinke SN,Kuligowski J,Wilson ID,Lewis MR,Dunn WB. Guidelines and considerations for the use of system suitability and quality control samples in mass spectrometry assays applied in untargeted clinical metabolomic studies. Metabolomics. 2018. 14(6):p. 72-72. IF:3,167. (2).