Autoclave sterilization of an in-house 3D-printed polylactic acid piece: biological safety and heat-induced deformation.
Autors de IIS La Fe
Autors aliens a IIS La Fe
- Angulo-Sánchez MÁ
Grups d'Investigació
Abstract
Fused filament fabrication 3D printing with polylactic acid filaments is the most widely used method to generate biomodels at hospitals throughout the world. The main limitation of this manufacturing system is related to the biomodels' temperature sensitivity, which all but prevents them to be sterilized using conventional methods. The purpose of this study is to define an autoclave temperature-resistant FFF-PLA 3D printing protocol to print 3D fractures biomodels during preoperative planning.
© 2021. Springer-Verlag GmbH Germany, part of Springer Nature.
Dades de la publicació
- ISSN/ISSNe:
- 1863-9933, 1863-9941
- Tipus:
- Article
- Pàgines:
- 3901-3910
- PubMed:
- 33959787
- Factor d'Impacte:
- 0,566 SCImago ℠
- Quartil:
- Q2 SCImago ℠
EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY Springer International Publishing AG
Cites Rebudes en Web of Science: 2
Documents
- No hi ha documents
Filiacions
Keywords
- 3D printing, Custom made models, Polylactic acid sterilization
Projectes associats
FACTORES DE RIESGO DE EXCESO DE INFLAMACION EN LA NEUMONIA. IMPACTO EN EL PRONOSTICO
Investigador Principal: ROSARIO MENÉNDEZ VILLANUEVA
BE-09/08 . 2008
HEALTH CARE ASSOCIATED PNEUMONIA (HCAP):MICROBIAL AETIOLOGY, RISK FACTORS AND PROGNOSTIC
Investigador Principal: ROSARIO MENÉNDEZ VILLANUEVA
PI08/0123 . INSTITUTO DE SALUD CARLOS III . 2009
FRACASO DEL TRATAMIENTO EN LANEUMONIA ADQUIRIDA EN LA COMUNIDAD. FACTORES DE RIESGO DE EXCESO DE INFLAMACION Y SU IMPACTO EN EL PRONOSTICO
Investigador Principal: ROSARIO MENÉNDEZ VILLANUEVA
PI08/0727 . INSTITUTO DE SALUD CARLOS III . 2009
ESTUDIO EN FASE IIIB MULTICÉNTRICO, ALEATORIZADO, DOBLE CIEGO Y CONTROLADO, PARA EVALUAR LA EFICACIA Y SEGURIDAD DE RIVAROXABAN 10 MG FRENTE A ENOXAPARINA 4.000 UI PARA LA PROFILAXIS DE TEV EN CIRUGÍA ORTOPÉDICA MENOR. ESTUDIO PRONOMOS.
Investigador Principal: FRANCISCO BAIXAULI GARCÍA
1408143 . 2017
ESTUDIO ALEATORIZADO, DOBLE CIEGO, DOBLE SIMULACIÓN, MULTICÉNTRICO, DE DISEÑO ADAPTATIVO DE ESCALADA DE DOSIS (PARTE 1) Y DOSIS-RESPUESTA (PARTE 2) PARA EVALUAR LA SEGURIDAD Y LA EFICACIA DE JNJ-64179375 FRENTE A APIXABAN ORAL EN SUJETOS SOMETIDOS A UN REEMPLAZO TOTAL DE RODILLA.
Investigador Principal: FRANCISCO BAIXAULI GARCÍA
64179375THR2001 . 2017
ESTUDIO ALEATORIZADO PARA EVALUAR LA SEGURIDAD Y LA EFICACIA DE JNJ-70033093 (BMS-986177) POR VÍA ORAL FRENTE A ENOXAPARINA EN SUJETOS SOMETIDOS A UNA INTERVENCIÓN QUIRÚRGICA PROGRAMADA DE REEMPLAZO TOTAL DE RODILLA.
Investigador Principal: FRANCISCO BAIXAULI GARCÍA
70033093THR2001 . 2020
ESTUDIO FASE II/III, ALEATORIZADO, CONTROLADO, SIMPLE CIEGO PARA EVALUAR LA EFICACIA HEMOSTÁTICA Y LA SEGURIDAD DE TT-173 EN APLICACIÓN TÓPICA A PACIENTES SOMETIDOS A ARTROPLASTIA DE RODILLA.
Investigador Principal: MANUEL ANGULO SÁNCHEZ
THO-IM_02-CT . 2016
SISTEMA ELECTRÓNICO DE DETECCIÓN RÁPIDA Y CUANTITATIVA DE INMUNOGLOBULINAS (IGA SECRETORA, IGGS E IGMS) PARA EL DIAGNÓSTICO PRECOZ DE COVID-19 MEDIANTE UN BIOSENSOR PORTÁTIL DE GRAFENO.
Investigador Principal: JOSÉ LUIS LÓPEZ HONTANGAS
2020-380-1_CRC_SUPERA_LOPEZ HONTANGAS . 2020
ESTUDIO EN FASE 2 ALEATORIZADO, CONTROLADO, ABIERTO (CIEGO PARA LA DOSIS), MULTICENTRICO, DE BUSQUEDA DE DOSIS DE SEGURIDAD Y EFICACIA DE I-0401 EN EL TRATAMIENTO DE PACIENTES CON FRACTURA DE MESETA TIBIAL QUE REQUIERAN INJERTO.
Investigador Principal: FRANCISCO BAIXAULI GARCÍA
CS-I-040101/02
ESTUDIO MULTICENTRICO, ALEATORIZADO, DOBLE-CIEGO, CONTROLADO CON PLACEBO DE GRUPOS PARALELOS PARA INVESTIGAR LA EFICACIA Y SEGURIDAD DE NORDITROPIN SIMPLEXX EN FRACTURAS DE TIBIA.
Investigador Principal: Francisco Baixauli Castella
NN1606-1365
ENSAYO CLINICO EN FASE IV ALEATORIZADO, ABIERTO, MULTICENTRICO Y DE NO INFERIORIDAD PARA COMPARAR LA SEGURIDAD Y LA EFICACIA DE COLISTINA IV. CON MEROPENEM IV. EN EL TRATAMIENTO DE LA NEUMONIA ASOCIADA A VENTILACION MECANICA
Investigador Principal: JUAN MANUEL BONASTRE MORA
MAGICBULLET/COLOMER
ESTUDIO DE FASE 3, PROSPECTIVO, MULTICÉNTRICO, PARA EVALUAR LA EFICACIA Y LA SEGURIDAD DEL FVWR CON O SIN ADVATE EN LOS PROCEDIMIENTOS QUIRÚRGICOS PROGRAMADOS EN SUJETOS CON ENFERMEDAD DE VON WILLEBRAND GRAVE.
Investigador Principal: ANA ROSA CID HARO
071101 . 2015
A PHASE 3 STUDY OF THE SAFETY AND EFFICACY OF COAGULATION FACTOR VIIA (RECOMBINANT) FOR THE PREVENTION OF EXCESSIVE BLEEDING IN CONGENITAL HEMOPHILIA A OR B PATIENTS WITH INHIBITORS TO FACTOR VIII OR IX UNDERGOING ELECTIVE SURGERY OR OTHER INVASIVE PROCEDURES (PERSEPT 3).
Investigador Principal: SANTIAGO BONANAD BOIX
LFB-FVIIA-008-14 . 2017
EFECTO DEL DENOSUMAB EN EL TRATAMIENTO DEL TUMOR DE CÉLULAS GIGANTES.
Investigador Principal: MANUEL ANGULO SÁNCHEZ
JFT-DEN-2019-01 . 2019
METABOLIZACIÓN DE DIGOXINA POR LA MICROBIOTA ENTÉRICA.
Investigador Principal: JOSÉ MIGUEL SAHUQUILLO ARCE
JSA-DIG-2019-01 . 2023