First Prospective, Single-Arm, Multicenter Study to Evaluate the Safety and Efficacy of the Overall Thrombectomy System for Stroke: iNedit, iNdeep, and iNtercept in Patients with Acute Ischemic Stroke (SEMTiC-01 Study)

Fecha de publicación:

Autores de IIS La Fe

Participantes ajenos a IIS La Fe

  • Chirife O.
  • Dolz G.
  • Delgado F.
  • Tomasello A.
  • Vega P.
  • Moreu M.
  • Castaño C.
  • Domínguez C.
  • Holtmannspötter M.
  • François O.
  • González E.
  • Aguilar Y.
  • Fernández L.
  • Castro Reyes E.
  • Meckel S.
  • Gramegna L.L.
  • Quintana Luque M.
  • Pich S.
  • Domingo-Rodriguez L.
  • Duran M.
  • Molina M.
  • Duocastella L.
  • San Román L.
  • Macho J.

Grupos

Abstract

BACKGROUND AND PURPOSE: Mechanical thrombectomy (MT) is the standard of care for acute ischemic stroke (AIS) due to large vessel occlusion (LVO), but the optimal combination of devices remains under investigation. The Safety and Efficacy of the Overall Thrombectomy System for Stroke (SEMTiC-01) trial evaluates the safety and efficacy of a novel, fully integrated neurothrombectomy system composed of the iNedit balloon distal access catheter, the iNdeep microcatheter, and the iNtercept stent retriever. MATERIALS AND METHODS: SEMTiC-01 is a prospective, multicenter, single-arm, open-label trial conducted across 18 centers in Spain, Germany, and Belgium. A total of 175 patients with LVO stroke were enrolled and treated within 24 hours of symptom onset. The primary efficacy end point was the rate of successful reperfusion (expanded Thrombolysis in Cerebral Infarction [eTICI] score =2b) in =3 passes. The primary safety end points included serious adverse events within 24 hours and 90-day mortality. Secondary end points included good functional outcome (mRS 0-2 at 90 days), early neurologic improvement, and device navigability. RESULTS: Successful reperfusion was achieved in 75.4% of the intention-to-treat (ITT) and 83.6% of the per-protocol (PP) popula- tion. Good functional outcomes were observed in 55.8% (ITT) and 56.9% (PP), and rapid neurologic improvement in 64.6% of patients. First-pass reperfusion (eTICI =2b) was obtained in 46.9% (ITT) and 51.4% (PP). Symptomatic intracranial hemorrhage occurred in 1.7% (ITT), and mortality at 90 days was 13.7%. Device navigability was rated good in more than 75% of cases for both iNedit, iNtercept, and iNdeep. Balloon inflation during thrombectomy improved outcomes in MI occlusions. CONCLUSIONS: The triad system (iNedit, iNdeep, and iNtercept) demonstrates noninferiority compared with published literature, with favorable safety and efficacy profiles. Its favorable navigability suggests it is a promising option for MT in AIS. © 2026, American Society of Neuroradiology. All right reserved.

Datos de la publicación

ISSN/ISSNe:
0195-6108, 1936-959X

AMERICAN JOURNAL OF NEURORADIOLOGY  AMER SOC NEURORADIOLOGY

Tipo:
Article
Páginas:
2318-2327
PubMed:
41714128
Enlace a otro recurso:
www.scopus.com
Factor de Impacto:
1,340 SCImago ℠
Cuartil:
Q1 SCImago ℠

Citas Recibidas en Web of Science: 1

Citas Recibidas en Scopus: 1

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Aged; Aged, 80 and over; Equipment Design; Equipment Failure Analysis; Female; Humans; Ischemic Stroke; Male; Middle Aged; Prospective Studies; Thrombectomy; Treatment Outcome; acute ischemic stroke; aged; all cause mortality; arterial embolization; artery dissection; artery perforation; Article; balloon occlusion; Belgium; brain hemorrhage; computer assisted tomography; deterioration; device safety; embolism; false aneurysm; female; Germany; hematoma; human; in vivo study; intention to treat analysis; internal carotid artery; major clinical study; male; mechanical thrombectomy; modified thrombolysis in cerebral infarction scale; multicenter study; National Institutes of Health Stroke Scale; nuclear magnetic resonance imaging; occlusion; prospective study; reperfusion; Spain; subarachnoid hemorrhage; treatment outcome; vasospasm; adverse event; clinical trial; device failure analysis; devices; equipment design; ischemic stroke; middle aged; mortality; procedures; surgery; thrombectomy;

Cita

Compartir