Zero-Contrast EVAR Can Be Reached Using Automated Carbon Dioxide Digital Angiography, Endoaortic Balloon Occlusion, and IVUS.

Fecha de publicación: Fecha Ahead of Print:

Autores de IIS La Fe

Participantes ajenos a IIS La Fe

  • Mursia FM
  • Bellmunt S

Grupos

Abstract

OBJECTIVE: To introduce a new method to enhance the visualization of renal arteries and the accuracy of graft deployment during CO(2)-assisted endovascular (EV) aneurysm repair (EVAR). METHODS: A retrospective observational study of consecutive EVAR cases assisted with CO(2) angiography (CO(2)Angio) was conducted. This nonrandomized design reflects real-life progressive attempts to enhance the reliability of CO(2) and intravascular ultrasound (IVUS), minimizing the use of iodinated contrast (IC) and radiation, respectively. Cases were divided into 3 groups according to consecutive periods: CO(2)Angio (n = 7), CO(2)Angio and balloon occlusion of the infrarenal aorta (CO(2)Angio + EVclamp, n = 11), and CO(2)Angio + EVclamp + IVUS (n = 18). IC was permitted in case of insufficient visualization with CO(2)Angio during any phase of the procedure. Demographic, clinical, and procedure variables (volume of IC and CO(2), radiation, fluoroscopy time, leaks) were collected from electronic clinic histories and statistically analyzed. RESULTS: A significant decrease was found in the third group, after introducing both techniques, for total radiation (air kerma; 3,039 ± 2,792.3 vs 3,434.7 ± 1,289.2 vs 2,284.6 ± 841.5 mGy, P = 0.041), radiation per area, dose area product (47 ± 34.7 vs 54.5 ± 15.3 vs 41.3 ± 12.8 mGy×m(2), P = 0.03), and IC volume (104.3 ± 102.4 vs 89.2 ± 53.9 vs 15.4 ± 27.4 mL, P < 0.001), arriving at the goal of "zero contrast" in the last 12 patients. No significant differences were detected in fluoroscopy time, total operative time, total CO(2) volume, or change in renal function. CONCLUSIONS: The introduction of endoluminal occlusion with a balloon and the use of IVUS in CO(2)-assisted EVAR enabled us to achieve the objective of zero contrast and a progressive decrease in radiation dose.

Datos de la publicación

ISSN/ISSNe:
1556-9845, 1559-0879

Innovations-Technology and Techniques in Cardiothoracic and Vascular Surgery  SAGE PUBLICATIONS INC

Tipo:
Article
Páginas:
-
PubMed:
42563252

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • CO2 angiography; EVAR; IVUS; aorta; aortic balloon

Cita

Compartir