Prediction of intrapartum fetal compromise at the end of pregnancy; is Doppler, and not weight, that matters.

Autores de IIS La Fe
Participantes ajenos a IIS La Fe
- Khalil A
Grupos
Abstract
Despite the fact that labor depends on too many interacting factors and no parameter can fully predict its outcome, fetal cerebral Doppler has emerged as the most reliable tool for prediction, in contrast with fetal weight, which performs significantly worse in the last weeks of pregnancy. The importance of the cerebral Doppler follows the inverse pathway of fetal weight increasing its performance in the last weeks of pregnancy and reaching its highest ability prior to labor. A combination of cerebral flow, fetal weight, and selected clinical information may obtain moderate predictions of labor outcome, provided the interval to labor is not long.
Copyright © 2024 The Author(s). Published by Elsevier B.V. All rights reserved.
Datos de la publicación
- ISSN/ISSNe:
- 0301-2115, 1872-7654
- Tipo:
- Article
- Páginas:
- 102-104
- Factor de Impacto:
- 0,635 SCImago ℠
- Cuartil:
- Q2 SCImago ℠
EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY ELSEVIER SCIENCE BV
Documentos
- No hay documentos
Filiaciones
Keywords
- Cardiotocogram; Cerebroplacental ratio; Fetal growth; Fetal monitoring; Intrapartum compromise; Labor outcome; Middle cerebral artery Doppler
Proyectos asociados
RED DE SALUD MATERNO INFANTIL Y DEL DESARROLLO
Investigador Principal: MÁXIMO VENTO TORRES
RD12/0026/0012 . INSTITUTO DE SALUD CARLOS III; FUNDACIÓN PARA LA INVESTIGACIÓN DEL HOSPITAL UNIVERSITARIO LA FE DE LA COMUNIDAD VALENCIANA . 2013
PAPEL DEL FACTOR DE CRECIMIENTO PLACENTARIO EN EL MANEJO DE LA PREECLAMPSIA NO SEVERA: ESTUDIO ALEATORIZADO
Investigador Principal: ALFREDO JOSÉ PERALES MARÍN
PI15/01935 . INSTITUTO DE SALUD CARLOS III . 2016
Iplacenta. innovation in pacenta modelling for maternal and fetal health.
Investigador Principal: JOSÉ MORALES ROSELLÓ
765274 . COMISION EUROPEA . 2018
ENSAYO MULTICÉNTRICO, ABIERTO, ALEATORIZADO, DE DOSIS ÚNICA, CONTROLADO, DE XOMA 213 ADMINISTRADO POR VÍA INTRAVENOSA A MUJERES DESPUÉS DEL PARTO PARA LA SUPRESIÓN DE LA LACTANCIA.
Investigador Principal: ALFREDO JOSÉ PERALES MARÍN
X213220
EVALUACIÓN DE LA EFICACIA DEL USO DE CLORHEXIDINA DURANTE EL PRIMER TRIMESTRE COMO REGULADOR DE LA MICROBIOTA VAGINAL EN LA REDUCCIÓN DE PARTO PREMATURO.
Investigador Principal: JOSÉ MORALES ROSELLÓ
PLUVA . 2021
Elaboración de un algoritmo de predicción de parto tras inducción basado en criterios clínicos, epidemiológicos y ecográficos.
Investigador Principal: JOSÉ MORALES ROSELLÓ
Prepain . 2023
Cita
Morales J,Khalil A. Prediction of intrapartum fetal compromise at the end of pregnancy; is Doppler, and not weight, that matters. Eur J Obstet Gynecol Reprod Biol. 2024. 301. p. 102-104. IF:2,100. (2).