Comparison of ductus venosus Doppler and cerebroplacental ratio for the prediction of adverse perinatal outcome in high-risk pregnancies before and after 34 weeks.

Autores de IIS La Fe
Participantes ajenos a IIS La Fe
- Bhate, Rohan
- Eltaweel, Nashwa
- Khalil, Asma
Grupos
Abstract
INTRODUCTION: The objective of the study was to compare the accuracy of the ductus venosus pulsatility index (DV PI) with that of the cerebroplacental ratio (CPR) for the prediction of adverse perinatal outcome at two gestational ages: <34 and =34 weeks' gestation. MATERIAL AND METHODS: This was a retrospective study of 169 high-risk pregnancies (72 < 34 and 97 = 34 weeks) that underwent an ultrasound examination of CPR, DV Doppler and estimated fetal weight at 22-40 weeks. The CPR and DV PI were converted into multiples of the median, and the estimated fetal weight into centiles according to local references. Adverse perinatal outcome was defined as a composite of abnormal cardiotocogram, intrapartum pH requiring cesarean delivery, 5' Apgar score <7, neonatal pH <7.10 and admission to neonatal intensive care unit. Values were plotted according to the interval to labor to evaluate progression of abnormal Doppler values, and their accuracy was evaluated at both gestational periods, alone and combined with clinical data, by means of univariable and multivariable models, using the Akaike information criteria (AIC) and the area under the curve (AUC). RESULTS: Prior to 34 weeks' gestation, DV PI was the latest parameter to become abnormal. However, it was a poor predictor of adverse perinatal outcome (AUC 0.56, 95% CI: 0.40-0.71, AIC 76.2, p > 0.05), and did not improve the predictive accuracy of CPR for adverse perinatal outcome (AUC 0.88, 95% CI: 0.79-0.97, AIC 52.9, p < 0.0001). After 34 weeks' gestation, the chronology of the DV PI and CPR anomalies overlapped, but again DV PI was a poor predictor for adverse perinatal outcome (AUC 0.62, 95% CI: 0.49-0.74, AIC 120.6, p > 0.05), that did not improve the CPR ability to predict adverse perinatal outcome (AUC 0.80, 95% CI: 0.67-0.92, AIC 106.8, p < 0.0001). The predictive accuracy of CPR prior to 34 weeks persisted when the gestational age at delivery was included in the model (AUC 0.91, 95% CI: 0.81-1.00, AIC 46.3, p < 0.0001, versus AUC 0.86, 95% CI: 0.72-1, AIC 56.1, p < 0.0001), and therefore was not determined by prematurity. CONCLUSIONS: CPR predicts adverse perinatal outcome better than DV PI, regardless of gestational age. Larger prospective studies are needed to delineate the role of ultrasound tools of fetal wellbeing assessment in predicting and preventing adverse perinatal outcome.
© 2023 The Authors. Acta Obstetricia et Gynecologica Scandinavica published by John Wiley & Sons Ltd on behalf of Nordic Federation of Societies of Obstetrics and Gynecology (NFOG).
Datos de la publicación
- ISSN/ISSNe:
- 0001-6349, 1600-0412
- Tipo:
- Article
- Páginas:
- 891-904
- DOI:
- 10.1111/aogs.14570
- Factor de Impacto:
- 1,232 SCImago ℠
- Cuartil:
- Q1 SCImago ℠
ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA Wiley-Blackwell
Documentos
- No hay documentos
Filiaciones
Keywords
- adverse perinatal outcome; cerebroplacental ratio; ductus venosus Doppler; fetal Doppler
Proyectos asociados
RED DE SALUD MATERNO INFANTIL Y DEL DESARROLLO
Investigador Principal: MÁXIMO VENTO TORRES
RD12/0026/0012 . INSTITUTO DE SALUD CARLOS III; FUNDACIÓN PARA LA INVESTIGACIÓN DEL HOSPITAL UNIVERSITARIO LA FE DE LA COMUNIDAD VALENCIANA . 2013
PAPEL DEL FACTOR DE CRECIMIENTO PLACENTARIO EN EL MANEJO DE LA PREECLAMPSIA NO SEVERA: ESTUDIO ALEATORIZADO
Investigador Principal: ALFREDO JOSÉ PERALES MARÍN
PI15/01935 . INSTITUTO DE SALUD CARLOS III . 2016
Iplacenta. innovation in pacenta modelling for maternal and fetal health.
Investigador Principal: JOSÉ MORALES ROSELLÓ
765274 . COMISION EUROPEA . 2018
ENSAYO MULTICÉNTRICO, ABIERTO, ALEATORIZADO, DE DOSIS ÚNICA, CONTROLADO, DE XOMA 213 ADMINISTRADO POR VÍA INTRAVENOSA A MUJERES DESPUÉS DEL PARTO PARA LA SUPRESIÓN DE LA LACTANCIA.
Investigador Principal: ALFREDO JOSÉ PERALES MARÍN
X213220
EVALUACIÓN DE LA EFICACIA DEL USO DE CLORHEXIDINA DURANTE EL PRIMER TRIMESTRE COMO REGULADOR DE LA MICROBIOTA VAGINAL EN LA REDUCCIÓN DE PARTO PREMATURO.
Investigador Principal: JOSÉ MORALES ROSELLÓ
PLUVA . 2021
Elaboración de un algoritmo de predicción de parto tras inducción basado en criterios clínicos, epidemiológicos y ecográficos.
Investigador Principal: JOSÉ MORALES ROSELLÓ
Prepain . 2023
Cita
Morales J,Bhate R,Eltaweel N,Khalil A. Comparison of ductus venosus Doppler and cerebroplacental ratio for the prediction of adverse perinatal outcome in high-risk pregnancies before and after 34 weeks. Acta Obstet Gynecol Scand. 2023. 102. (7):p. 891-904. IF:3,500. (1).