SfM-3DULC: Reliability of a new 3D wound measurement procedure and its accuracy in projected area.
Fecha de publicación:
Fecha Ahead of Print:
Autores de IIS La Fe
Participantes ajenos a IIS La Fe
- Sánchez-Jiménez D
- Buchón-Moragues FF
Grupos
Abstract
Three-dimensional (3D) wound measurement lacks a gold standard to test accuracy. It is useful to develop procedures to scan wounds and reconstruct their 3D model with low-cost techniques. We present a new procedure (Structure from Motion [SfM]-3DULC) that uses photographs for measuring nine wound variables. We also propose a new variant of ImageJ in which an orthophoto is used to measure the projected area (Ortho-ImageJ). In addition, we compare the wound measurements made by dermatologists and non-experts. A group of five experts in dermatology and five non-specialists measured 33 leg wounds five times per procedure. Intra-rater and inter-rater reliability scores of SfM-3DULC were evaluated with the intraclass correlation coefficient (ICC 2,1). The accuracy of the two new procedures (SfM-3DULC and Ortho-ImageJ) in the measurement of projected area was assessed by comparing their values with those obtained using ImageJ, with the Wilcoxon matched-pairs signed rank test (a = 0.05). This test was also used to analyse the differences between the measurements made by dermatologists and non-experts. All the variables measured by dermatologists using SfM-3DULC showed excellent scores of intra-rater reliability (ICC > 0.99) and inter-rater reliability (ICC > 0.98). No significant differences between the three procedures were found when comparing their projected area values. Significant differences between the measurements of dermatologists and non-experts were found in most of the variables: circularity coefficient, perimeter, projected area, surface area, and reference surface area. The wound measurement procedure SfM-3DULC has an excellent reliability, is accurate for the measurement of projected area, and can be used by dermatologists for wound monitoring in everyday clinical practice.
© 2021 The Authors. International Wound Journal published by Medicalhelplines.com Inc (3M) and John Wiley & Sons Ltd.
Datos de la publicación
- ISSN/ISSNe:
- 1742-4801, 1742-481X
- Tipo:
- Article
- Páginas:
- 44-51
- DOI:
- 10.1111/iwj.13595
- PubMed:
- 34002925
- Factor de Impacto:
- 0,624 SCImago ℠
- Cuartil:
- Q2 SCImago ℠
International Wound Journal WILEY
Citas Recibidas en Web of Science: 8
Documentos
- No hay documentos
Filiaciones
Keywords
- 3DULC, ImageJ, SfM, measurement, wound
Campos de Estudio
Cita
Sánchez D,Buchón FF,ESCUTIA B,BOTELLA R. SfM-3DULC: Reliability of a new 3D wound measurement procedure and its accuracy in projected area. Int. Wound J. 2021. 19. (1):p. 44-51. IF:3,099. (2).