PET/CT: underlying physics, instrumentation, and advances.

Fecha de publicación:

Autores de IIS La Fe

Grupos

Abstract

Since it was first introduced, the main goal of PET/CT has been to provide both PET and CT images with high clinical quality and to present them to radiologists and specialists in nuclear medicine as a fused, perfectly aligned image. The use of fused PET and CT images quickly became routine in clinical practice, showing the great potential of these hybrid scanners. Thanks to this success, manufacturers have gone beyond considering CT as a mere attenuation corrector for PET, concentrating instead on design high performance PET and CT scanners with more interesting features. Since the first commercial PET/CT scanner became available in 2001, both the PET component and the CT component have improved immensely. In the case of PET, faster scintillation crystals with high stopping power such as LYSO crystals have enabled more sensitive devices to be built, making it possible to reduce the number of undesired coincidence events and to use time of flight (TOF) techniques. All these advances have improved lesion detection, especially in situations with very noisy backgrounds. Iterative reconstruction methods, together with the corrections carried out during the reconstruction and the use of the point-spread function, have improved image quality. In parallel, CT instrumentation has also improved significantly, and 64- and 128-row detectors have been incorporated into the most modern PET/CT scanners. This makes it possible to obtain high quality diagnostic anatomic images in a few seconds that both enable the correction of PET attenuation and provide information for diagnosis. Furthermore, nowadays nearly all PET/CT scanners have a system that modulates the dose of radiation that the patient is exposed to in the CT study in function of the region scanned. This article reviews the underlying physics of PET and CT imaging separately, describes the changes in the instrumentation and standard protocols in a combined PET/CT system, and finally points out the most important advances in this hybrid imaging modality.

Datos de la publicación

ISSN/ISSNe:
0033-8338, 1578-178X

Radiologia  ELSEVIER ESPANA S I

Tipo:
Article
Páginas:
431-445
PubMed:
28089381
Factor de Impacto:
0,192 SCImago
Cuartil:
Q4 SCImago

Citas Recibidas en Web of Science: 6

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Algoritmos iterativos; Centelleadores rapidos; Computed tomography; Dose modulation; Fast scintillation crystals; Hybrid imaging; Imagen hibrida; Iterative algorithms; Modulacion de dosis; Multidetector CT; PET; Positron emission tomography; TAC; TAC multidetector; Tiempo de vuelo; Time of flight

Proyectos y Estudios Clínicos

CONTROL Y SEGUIMIENTO INTEGRAL DE LA RADIACIÓN IONIZANTE RECIBIDA TRAS EXPLORACIONES MÉDICAS: COSIRI.

Investigador Principal: ÁNGEL ALBERICH BAYARRI

GV/2015/132 . FUNDACIÓN PARA LA INVESTIGACIÓN DEL HOSPITAL UNIVERSITARIO LA FE DE LA COMUNIDAD VALENCIANA; CONSELLERIA DE EDUCACION . 2015

PROSPET. DISPOSITIVO MULTI-IMAGEN CON UN DETECTOR PET PARA GUIAR LA BIOPSIA, EL TRATAMIENTO Y EL SEGUIMIENTO DEL CÁNCER DE PRÓSTATA.

Investigador Principal: CÉSAR DAVID VERA DONOSO

DTS15/00044 . INSTITUTO DE SALUD CARLOS III . 2016

ENSAYO FASE III, RANDOMIZADO, DOBLE CIEGO, CONTROLADO CON PLACEBO, EN GRUPOS PARALELOS, MULTICÉNTRICO, PARA VALORAR LA EFICACIA Y SEGURIDAD DE GANTENERUMAB EN PACIENTES CON ENFERMEDAD DE ALZHEIMER LEVE.

Investigador Principal: MIGUEL BAQUERO TOLEDO

WN28745 . 2014

ENSAYO CLINICO EN FASE III, DE "THERASPHERE" INTRAARTERIAL PARA EL TRATAMIENTO DE PACIENTES CON CARCINOMA HEPATOCELULAR(CHC) NO RESECALBE.

Investigador Principal: DANIEL PÉREZ ENGUIX

TS-103 . 2016

ESTUDIO EN FASE I DE DETERMINACIÓN DE LA DOSIS DE 177LU-DOTA-HH1 (BETALUTIN®) EN PACIENTES CON LINFOMA DIFUSO DE LINFOCITOS B GRANDES RECIDIVANTE NO ELEGIBLES PARA EL AUTOTRASPLANTE DE CÉLULAS MADRE.

Investigador Principal: JOSÉ GÓMEZ CODINA

LYMRIT-37-05 . 2016

ESTUDIO EN FASE III, MULTICÉNTRICO, ALEATORIZADO, DOBLE CIEGO, CONTROLADO CON PLACEBO Y DE GRUPOS PARALELOS PARA EVALUAR LA EFICACIA Y SEGURIDAD DE CRENEZUMAB EN PACIENTES CON ENFERMEDAD DE ALZHEIMER DE PRODRÓMICA A LEVE

Investigador Principal: MIGUEL BAQUERO TOLEDO

BN29552 . 2016

ESTUDIO ALEATORIZADO, DOBLE CIEGO, CONTROLADO CON PLACEBO Y DE COMIENZO APLAZADO DE LY3314814 EN LA DEMENCIA DE LA ENFERMEDAD DE ALZHEIMER LEVE (ESTUDIO DAYBREAK)

Investigador Principal: MIGUEL BAQUERO TOLEDO

I8D-MC-AZET . FUNDACIÓN PARA LA INVESTIGACIÓN DEL HOSPITAL UNIVERSITARIO LA FE DE LA COMUNIDAD VALENCIANA . 2017

Cita

Compartir