Individualised dosimetry in patients with differentiated thyroid cancer based on external dose-rate. Optimisation of the number of measurements

Fecha de publicación:

Autores de IIS La Fe

Participantes ajenos a IIS La Fe

  • Borrelli, P

Grupos

Abstract

Objectives: To compare the results of individual dosimetry in differentiated thyroid cancer patients treated with I-131 at our centre with the established limits and dosimetry results of published studies. Analysis of the optimal number of measurements necessary to reduce the impact of dosimetry for the comfort of the patient and, secondly, on the workload of health workers. Material and methods: Dosimetry was performed in the Nuclear Medicine Department of the University and Polytechnic Hospital La Fe, on 29 patients suffering from differentiated thyroid cancer and treated with activities between 1.02 and 5.51 GBq (mean 2.68 GBq) of I-131. The Spanish Society of Medical Physics (SEFM) protocol was used, based on measurements of external dose rate adjusted to a bi-exponential curve according to a two compartment model. Different dosimetries were performed on each patient, taking different selections of the available measurements in order to find the optimal number. Results: Results are well below the dosimetry limits, and are consistent with those obtained in other centres. The number of measurements can be reduced from 5, as proposed in the SEFM protocol, to 4 without significant loss of accuracy. Further reducing measures may be justified in individual cases. Conclusions: The values obtained for the dosimetry quantities are significantly below the established limits. A reduction in measurements can be assumed at the cost of a moderate increase in uncertainty, benefiting the patient. (C) 2015 Elsevier Espana, S.L.U. and SEMNIM. All rights reserved.

Datos de la publicación

ISSN/ISSNe:
2253-654X, 2253-8070

Revista Espanola de Medicina Nuclear e Imagen Molecular  ELSEVIER ESPANA SLU

Tipo:
Article
Páginas:
107-114
PubMed:
26598429
Factor de Impacto:
0,244 SCImago ℠
Cuartil:
Q3 SCImago ℠

Citas Recibidas en Web of Science: 3

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Differentiated thyroid carcinoma; Individualised dosimetry; I-131; Metabolic therapy

Cita

Compartir