Determination of meropenem in endotracheal tubes by in-tube solid phase microextraction coupled to capillary liquid chromatography with diode array detection

Fecha de publicación:

Autores de IIS La Fe

Participantes ajenos a IIS La Fe

  • Hakobyan, L
  • Tolos, JP
  • Moliner-Martinez, Y
  • Molins-Legua, C

Grupos

Abstract

Meropenem is a widely used antimicrobial for the treatment of infections associated with the use of invasive medical devices in intensive care unit patients. These treatments are not always effective, in fact, in-vitro studies have demonstrated the difficulty of antimicrobials to penetrate into the biofilm, however in-vivo studies of the effect of these compounds is a trend, mostly because of the complexity of pulmonary samples extracted from ETTs. Therefore, the objective of this study was to evaluate in-tube solid phase microextraction (in-tube SPME) coupled to capillary liquid chromatography (CapLC) with DAD to determine meropenem in Errs in order to estimate the penetration capability into the biofilm. Firstly, different parameter affecting in-tube SPME, such as processed sample volume, capillary length, flow and capillary coating were studied. The best analytical response was achieved by processing 500 mu L of standards samples at 9 mu L/seg with a 60-cm capillary column coated with 35%-diphenyl 65%-polydimethylsiloxane. Under these conditions, the analytical performance of in-tube SPME-CapLC-DAD, using acetonitrile-water in gradient mode as mobile phase, showed satisfactory results for estimation of meropenem in terms of sensitivity (LOD = 3 mu g/L) and predsion (RSD < 10%). Once the experimental conditions were stablished for in-tube SPME, the extraction of meropenem from the ETrs was studied. Liquid extraction, vortex-assisted liquid extraction (VALE) and ultrasound-extraction (UAE) extraction were tested. The results indicated that meropenem could be quantitatively extracted (91 +/- 6%) from Errs, for its subsequent determination by in-tube SPME-CapLC-DAD using water as extraction solvent and 1 min as extraction time. Finally, samples from Errs used for critically ill patients with different antimicrobial treatments were analysed with successful results. (C) 2018 Elsevier B.V. All rights reserved.

Datos de la publicación

ISSN/ISSNe:
0731-7085, 1873-264X

Journal of Pharmaceutical and Biomedical Analysis  ELSEVIER

Tipo:
Article
Páginas:
170-177
PubMed:
29331796
Factor de Impacto:
0,786 SCImago
Cuartil:
Q1 SCImago

Citas Recibidas en Web of Science: 15

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • In-tube SPME; Capillary-LC-DAD; Meropenem; Endotracheal tubes; Biofilm

Cita

Compartir