Spanish Pacemaker Registry. Thirteenth Official Report of the Spanish Society of Cardiology Working Group on Cardiac Pacing (2015).

Fecha de publicación:

Autores de IIS La Fe

Participantes ajenos a IIS La Fe

  • Jimenez, MP
  • Andres, MLF
  • Carreno, DL
  • Samartin, RC

Grupos

Abstract

INTRODUCTION AND OBJECTIVES: We describe the results of the analysis of the devices implanted and conveyed to the Spanish Pacemaker Registry in 2015. METHODS: The report is based on the processing of information provided by the European Pacemaker Patient Identification Card. RESULTS: We received information from 111 hospitals, with a total of 12 555 cards, representing 32.1% of all the estimated activity. The use of conventional generators and resynchronization devices was 820 and 73 units per million population, respectively. The mean age of the patients receiving an implantation was 77.7 years, and more than 50% of the devices were implanted in patients over 80 years of age. Overall, 58.6% of the implants and 58.8% of the replacements were performed in men. All of the endocardial leads employed were bipolar, 81.5% had an active fixation system, and 16.5% were compatible with magnetic resonance. Although dual chamber sequential pacing continues to be more widespread, pacing with VVI/R mode is used because up to 23.8% of the patients with sinus node disease are in sinus rhythm, as are 24.1% of those with atrioventricular block. CONCLUSIONS: The total use of pacemaker generators in Spain has increased by about 5% with respect to 2014. The majority of the leads implanted are of active fixation, and less than 20% are protected from magnetic resonance. The factors directly related to the selection of pacing mode are age and sex. In around 20% of patients, the choice of the pacing mode could be improved.

Datos de la publicación

ISSN/ISSNe:
1885-5857, 1885-5857

REVISTA ESPANOLA DE CARDIOLOGIA  Elsevier Doyma

Tipo:
Article
Páginas:
1190-1203
PubMed:
27825715
Factor de Impacto:
0,146 SCImago
Cuartil:
Q4 SCImago

Citas Recibidas en Web of Science: 9

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • *Cables marcapasos; *Dual chamber pacing; *Estimulacion biventricular; *Marcapasos; *Pacemaker leads; *Pacemakers; *Registro; *Registry

Proyectos y Estudios Clínicos

MORE-CRT: EL AUMENTO DE LAS OPCIONES DISPONIBLES CON UN ELECTRODO VI TETRAPOLAR OFRECE SOLUCIONES CLÍNICAS A LOS PROBLEMAS DE LA TRC. MORE OPTIONS AVAILABLE WITH A QUADRIPOLAR LV LEAD PROVIDE IN CLINIC SOLUTIONS TO CRT CHALLENGES.

Investigador Principal: JOAQUÍN OSCA ASENSI

CR-11-006-HF-ID . 2012

GLORIA - AF: REGISTRO GLOBAL DEL TRATAMIENTO ANTITROMBÓTICO ORAL A LARGO PLAZO EN PACIENTES CON FIBRILACIÓN AURICULAR (FASE II/III – ESTADOS MIEMBROS DE LA UE/ AEE).

Investigador Principal: JOAQUÍN OSCA ASENSI

BOE-DAB-2012-01 . 2013

MORE RESPONSE ON CARDIAC RESYNCHRONIZATION THERAPY (CRT) WITH MULTIPOINT PACING (MPP) – MAYOR RESPUESTA A LA TERAPIA DE RESINCRONIZACIÓN CARDIACA (TRC) CON ESTIMULACIÓN MULTISITIO.

Investigador Principal: JOAQUÍN OSCA ASENSI

CR-13-006-ID-HF . 2013

ESTIMULACIÓN TRICAMERAL EN PACIENTES CON CARDIOMIOPATÍA HIPERTRÓFICA OBSTRUCTIVA. TRICHAMPION (TRIPLE CHAMBER PACING IN HOCM PATIENTS).

Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA

CR-11-030-EU-HF . 2014

INVESTIGACIÓN CLÍNICA SOBRE LAS DIFERENCIAS EN LA MAGNITUD DE LA RESPUESTA A LA TRC ENTRE HOMBRES Y MUJERES. (BIOWOMEN).

Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA

CR017 . 2015

ESTIMULACIÓN BIVENTRICULAR TRIFOCAL PARA LA OPTIMIZACIÓN DE LA TERAPIA DE RESINCRONIZACIÓN CARDIACA (TRC).

Investigador Principal: ÓSCAR CANO PÉREZ

ICSY02 . 2015

EVALUACIÓN CLÍNICA DEL PACIENTE Y FUNCIONAL DEL DISPOSITIVO EN LA PRÁCTICA CLÍNICA HABITUAL CON PORTADORES DE DAI.

Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA

RTSY03 . 2015

OPCIONES DE LA TERAPIA DE RESINCRONIZACIÓN CON EL ELECTRODO QUARTET TM (QUARTET LEAD AND RESYNCHRONIZATION THERAPY OPTIONS) III.

Investigador Principal: JOAQUÍN OSCA ASENSI

CRD_789 . 2015

REGISTRO DE ESTIMULACIÓN TRANSCATÉTER CON EL SISTEMA MICRATM (MICRA)

Investigador Principal: JOAQUÍN OSCA ASENSI

ESTUDIO MICRA PM . 2017

ESTIMULACIÓN SÍNCRONA MULTIPUNTO FRENTE A ESTIMULACIÓN SECUENCIAL MULTIPUNTO DEL VENTRÍCULO IZQUIERDO PARA TRC. ESTUDIO SYNSEQ.

Investigador Principal: JOAQUÍN OSCA ASENSI

ESTUDIO SYNSEQ . 2016

ESTUDIO OASIS-H. ORGANIZACION ASISTENCIAL DE PACIENTES CON HOME MONITORING.

Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA

OASIS-HM . 2010

ENSAYO CLÍNICO DEL ELECTRODO SONRTIP Y EL ALGORITMO DE OPTIMIZACIÓN AV-VV EN EL PARADYM RF SONR CRT-D.

Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA

ITSY06 . 2012

ESTUDIO ABIERTO, FASE IV, MULTICÉNTRICO, PARA EVALUAR LA EFICACIA DIAGNÓSTICA DE NUUBO NECGBAND ANTES DEL HOLTER IMPLANTABLE.

Investigador Principal: ÓSCAR CANO PÉREZ

SYN201401 . 2015

ESTUDIO DE LA EFICACIA Y LA SEGURIDAD DE F373280 EN EL MANTENIMIENTO DEL RITMO SINUSAL TRAS CARDIOVERSIÓN ELÉCTRICA EN PACIENTES CON FIBRILACIÓN AURICULAR PERSISTENTE E INSUFICIENCIA CARDÍACA CRÓNICA. INTERNACIONAL, MULTICÉNTRICO, ALEATORIZADO, DOBLE CIEG O Y CONTROLADO CON PLACEBO.

Investigador Principal: JOAQUÍN OSCA ASENSI

F373280CA201

ESTUDIO OBSERVACIONAL PARA LA EVALUACIÓN DEL MANEJO DE PACIENTES RESINCRONIZADOS CON EL ELECTRODO TETRAPOLAR QUARTETTM DE VENTRÍCULO IZQUIERDO.

Investigador Principal: JOSE OLAGUE DE ROS

CR-12-015-SP-HF

REDUCCIÓN DE CHOQUES INAPROPIADOS CON EL DISCRIMINADOR DE RITMO PARAD+.

Investigador Principal: JOSE OLAGUE DE ROS

ITSY09

EVALUACIÓN NO INVASIVA DE LA ESTIMACIÓN DEL RIESGO POST-INFARTO - EFICACIA DE UN DAI.

Investigador Principal: JOAQUÍN OSCA ASENSI

REFINE_ICD

Cita

Compartir