Novel simple templates for reproducible positioning of skin applicators in brachytherapy

Autores de IIS La Fe
Participantes ajenos a IIS La Fe
- Villalba, SR
- Garcia-Martinez, T
- Richart, J
- Ortega, MS
- Silla, M
- Ballester, F
Grupos
Abstract
Purpose: Esteya and Valencia surface applicators are designed to treat skin tumors using brachytherapy. In clinical practice, in order to avoid errors that may affect the treatment outcome, there are two issues that need to be carefully addressed. First, the selected applicator for the treatment should provide adequate margin for the target, and second, the applicator has to be precisely positioned before each treatment fraction. In this work, we describe the development and use of a new acrylic templates named Template La Fe-ITIC. They have been designed specifically to help the clinical user in the selection of the correct applicator, and to assist the medical staff in reproducing the positioning of the applicator. These templates are freely available upon request. Material and methods: Templates that were developed by University and Polytechnic Hospital La Fe (La Fe) and Hospital Clinica Benidorm (ITIC) in cooperation with Elekta, consist of a thin sheet made of transparent acrylic. For each applicator, a crosshair and two different circles are drawn on these templates: the inner one corresponds to the useful beam, while the outer one represents the external perimeter of the applicator. The outer circle contains slits that facilitate to draw a circle on the skin of the patient for exact positioning of the applicator. In addition, there are two perpendicular rulers to define the adequate margin. For each applicator size, a specific template was developed. Results: The templates have been used successfully in our institutions for more than 50 patients' brachytherapy treatments. They are currently being used for Esteya and Valencia applicators. Conclusions: The template La Fe-ITIC is simple and practical. It improves both the set-up time and reproducibility. It helps to establish the adequate margins, an essential point in the clinical outcome.
Datos de la publicación
- ISSN/ISSNe:
- 1689-832X, 2081-2841
- Tipo:
- Review
- Páginas:
- 344-348
- Factor de Impacto:
- 0,467 SCImago ℠
- Cuartil:
- Q3 SCImago ℠
Journal of contemporary brachytherapy TERMEDIA PUBLISHING HOUSE LTD
Citas Recibidas en Web of Science: 9
Documentos
- No hay documentos
Filiaciones
Keywords
- brachytherapy; electronic brachytherapy; skin applicators; skin cancer; template
Proyectos asociados
MEDIDA DEL IMPACTO DE LA RADIOTERAPIA CON INTENCIÓN CURATIVA COMBINADA O NO CON TERAPIA HORMONAL SOBRE LA CALIDAD DE VIDA EN LA PRÁCTICA CLÍNICA EN EL CÁNCER DE PRÓSTATA LOCALIZADO. ESTUDIO VEPIC-ORT.
Investigador Principal: FRANCISCO JAVIER CELADA ÁLVAREZ
ONC-MA-1003 . 2016
ESTUDIO DESCRIPTIVO DEL PERFIL DEL PACIENTE CON CANCER DE PROSTATA EN CONSULTA DE ONCOLOGIA RADIOTERAPICA.
Investigador Principal: ALEJANDRO TORMO MICO
ONC-RT01-10 . 2011
ESTUDIO EPIDEMIOLÓGICO OBSERVACIONAL PROSPECTIVO DEL MANEJO DEL DOLOR EN PACIENTES ONCOLÓGICOS EN TRATAMIENTO RADIOTERÁPICO.
Investigador Principal: FRANCISCO JOSÉ MARTÍNEZ ARCELUS
GOR-ANA-2012-01
TRATAMIENTO RADIOTERÁPICO EN PACIENTES CON CÁNCER DE PRÓSTATA EN FUNCIÓN DEL NIVEL DE RIESGO CONFORME A LA PRÁCTICA CLÍNICA HABITUAL EN LOS SERVICIOS DE ONCOLOGÍA RADIOTERÁPICA ESPAÑOLES.
Investigador Principal: ERICA COLLADO BALLESTEROS
GIC-RAD-2013-01
ESTUDIO DE BRAQUITERAPIA ELECTRÓNICA PARA CARCINOMA CUTÁNEO BASOCELULAR.
Investigador Principal: JOSÉ PÉREZ CALATAYUD
BCCBRACHY
EFECTIVIDAD DE LOS NUEVOS TRATAMIENTOS PARA EL CÁNCER DE PRÓSTATA LOCALIZADO DE BAJO RIESGO.
Investigador Principal: ALEJANDRO TORMO MICO
TTOPRÓSTATA/OBS
Cita
Villalba SR,Perez MJ,Bautista JA,Carmona V,Celada F,Tormo A,Garcia T,Richart J,Ortega MS,Silla M,Ballester F. Novel simple templates for reproducible positioning of skin applicators in brachytherapy. J Contemp Brachytherapy. 2016. 8(4):p. 344-348. IF:1,496. (3).