Spanish Pacemaker Registry. Twelfth Official Report of the Spanish Society of Cardiology Working Group on Cardiac Pacing (2014).
Autores de IIS La Fe
Participantes ajenos a IIS La Fe
- Jimenez, MP
- Samartin, RC
Grupos
Abstract
INTRODUCTION AND OBJECTIVES: This report describes the results of the analysis of pacemaker implant and replacement data submitted to the Spanish Pacemaker Registry in 2014, with special reference to pacing mode selection. METHODS: The report is based on the processing of information provided by the European Pacemaker Patient Identification Card. RESULTS: Information was received from 117 hospitals, with a total of 12 358 cards, representing 34% of estimated activity. Use of conventional generators and resynchronization devices was 784 and 64.4 units per million population, respectively. The mean age of patients receiving an implant was 77.3 years. Men received 59% of implants and 56.4% of replacements. Most patients receiving generator implants and replacements were in the age range 80 to 89 years. Most endocardial leads used were bipolar, and 84.2% had an active fixation system. Pacing was in VVI/R mode despite being in sinus rhythm in 24.7% of patients with sick sinus syndrome and 24% of those with atrioventricular block. CONCLUSIONS: The use of pacemaker generators and resynchronization devices per million population continued to increase. Most implanted leads had active fixation and approximately 20% had magnetic resonance imaging protection. Age and sex directly influenced pacing mode selection, which could have been improved in more than 20% of cases.
Datos de la publicación
- ISSN/ISSNe:
- 1885-5857, 1885-5857
- Tipo:
- Article
- Páginas:
- 1138-1153
- PubMed:
- 26553269
- Factor de Impacto:
- 0,141 SCImago ℠
- Cuartil:
- Q4 SCImago ℠
REVISTA ESPANOLA DE CARDIOLOGIA Elsevier Doyma
Citas Recibidas en Web of Science: 11
Documentos
- No hay documentos
Filiaciones
Keywords
- Biventricular pacing; Cables marcapasos; Estimulacion biventricular; Marcapasos; Pacemaker; Pacemaker leads; Registro; Registry
Proyectos y Estudios Clínicos
MORE-CRT: EL AUMENTO DE LAS OPCIONES DISPONIBLES CON UN ELECTRODO VI TETRAPOLAR OFRECE SOLUCIONES CLÍNICAS A LOS PROBLEMAS DE LA TRC. MORE OPTIONS AVAILABLE WITH A QUADRIPOLAR LV LEAD PROVIDE IN CLINIC SOLUTIONS TO CRT CHALLENGES.
Investigador Principal: JOAQUÍN OSCA ASENSI
CR-11-006-HF-ID . 2012
GLORIA - AF: REGISTRO GLOBAL DEL TRATAMIENTO ANTITROMBÓTICO ORAL A LARGO PLAZO EN PACIENTES CON FIBRILACIÓN AURICULAR (FASE II/III – ESTADOS MIEMBROS DE LA UE/ AEE).
Investigador Principal: JOAQUÍN OSCA ASENSI
BOE-DAB-2012-01 . 2013
MORE RESPONSE ON CARDIAC RESYNCHRONIZATION THERAPY (CRT) WITH MULTIPOINT PACING (MPP) – MAYOR RESPUESTA A LA TERAPIA DE RESINCRONIZACIÓN CARDIACA (TRC) CON ESTIMULACIÓN MULTISITIO.
Investigador Principal: JOAQUÍN OSCA ASENSI
CR-13-006-ID-HF . 2013
ESTIMULACIÓN TRICAMERAL EN PACIENTES CON CARDIOMIOPATÍA HIPERTRÓFICA OBSTRUCTIVA. TRICHAMPION (TRIPLE CHAMBER PACING IN HOCM PATIENTS).
Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA
CR-11-030-EU-HF . 2014
INVESTIGACIÓN CLÍNICA SOBRE LAS DIFERENCIAS EN LA MAGNITUD DE LA RESPUESTA A LA TRC ENTRE HOMBRES Y MUJERES. (BIOWOMEN).
Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA
CR017 . 2015
ESTIMULACIÓN BIVENTRICULAR TRIFOCAL PARA LA OPTIMIZACIÓN DE LA TERAPIA DE RESINCRONIZACIÓN CARDIACA (TRC).
Investigador Principal: ÓSCAR CANO PÉREZ
ICSY02 . 2015
EVALUACIÓN CLÍNICA DEL PACIENTE Y FUNCIONAL DEL DISPOSITIVO EN LA PRÁCTICA CLÍNICA HABITUAL CON PORTADORES DE DAI.
Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA
RTSY03 . 2015
OPCIONES DE LA TERAPIA DE RESINCRONIZACIÓN CON EL ELECTRODO QUARTET TM (QUARTET LEAD AND RESYNCHRONIZATION THERAPY OPTIONS) III.
Investigador Principal: JOAQUÍN OSCA ASENSI
CRD_789 . 2015
REGISTRO DE ESTIMULACIÓN TRANSCATÉTER CON EL SISTEMA MICRATM (MICRA)
Investigador Principal: JOAQUÍN OSCA ASENSI
ESTUDIO MICRA PM . 2017
ESTUDIO OASIS-H. ORGANIZACION ASISTENCIAL DE PACIENTES CON HOME MONITORING.
Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA
OASIS-HM . 2010
ENSAYO CLÍNICO DEL ELECTRODO SONRTIP Y EL ALGORITMO DE OPTIMIZACIÓN AV-VV EN EL PARADYM RF SONR CRT-D.
Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA
ITSY06 . 2012
EVALUACIÓN DEL TRATAMIENTO ININTERRUMPIDO ALEATORIZADO CON DABIGATRÁN ETEXILATO COMPARADO CON WARFARINA EN LA ABLACIÓN DE VENAS PULMONARES: VALORACIÓN DE LA TERAPIA ANTICOAGULANTE ININTERRUMPIDA PERIPROCEDIMIENTO (ESTUDIO RE-CIRCUIT, RANDOMISED EVALUATION OF DABIGATRAN ETEXILATE COMPARED TO WARFARIN IN PULMONARY VEIN ABLATION: ASSESSMENT OF AN UNINTERRUPTED PERIPROCEDURAL ANTICOAGULATION STRATEGY).
Investigador Principal: JOAQUÍN OSCA ASENSI
1160.204 . 2015
EVALUACIÓN DE UN PROGRAMA EDUCACIÓN Y GUÍA PARA LA ADHERENCIA A ELIQUIS EN FIBRILACIÓN AURICULAR NO VALVULAR (AEGEAN).
Investigador Principal: MARÍA VILAR PALOP
CV185220 . 2014
ESTUDIO ABIERTO, FASE IV, MULTICÉNTRICO, PARA EVALUAR LA EFICACIA DIAGNÓSTICA DE NUUBO NECGBAND ANTES DEL HOLTER IMPLANTABLE.
Investigador Principal: ÓSCAR CANO PÉREZ
SYN201401 . 2015
MONITORING RESYNCHRONIZATION IN CARDIAC PATIENTS.
Investigador Principal: JOSE OLAGUE DE ROS
MORE-CARESTUDY . 2009
ESTUDIO DE LA EFICACIA Y LA SEGURIDAD DE F373280 EN EL MANTENIMIENTO DEL RITMO SINUSAL TRAS CARDIOVERSIÓN ELÉCTRICA EN PACIENTES CON FIBRILACIÓN AURICULAR PERSISTENTE E INSUFICIENCIA CARDÍACA CRÓNICA. INTERNACIONAL, MULTICÉNTRICO, ALEATORIZADO, DOBLE CIEG O Y CONTROLADO CON PLACEBO.
Investigador Principal: JOAQUÍN OSCA ASENSI
F373280CA201
ESTUDIO OBSERVACIONAL PARA LA EVALUACIÓN DEL MANEJO DE PACIENTES RESINCRONIZADOS CON EL ELECTRODO TETRAPOLAR QUARTETTM DE VENTRÍCULO IZQUIERDO.
Investigador Principal: JOSE OLAGUE DE ROS
CR-12-015-SP-HF
REDUCCIÓN DE CHOQUES INAPROPIADOS CON EL DISCRIMINADOR DE RITMO PARAD+.
Investigador Principal: JOSE OLAGUE DE ROS
ITSY09
EVALUACIÓN NO INVASIVA DE LA ESTIMACIÓN DEL RIESGO POST-INFARTO - EFICACIA DE UN DAI.
Investigador Principal: JOAQUÍN OSCA ASENSI
REFINE_ICD
Cita
PEREZ OC,Jimenez MP,Samartin RC. Spanish Pacemaker Registry. Twelfth Official Report of the Spanish Society of Cardiology Working Group on Cardiac Pacing (2014). Rev Esp Cardiol (Engl Ed). 2015. 68. (12):p. 1138-1153.