CRT Survey II: a European Society of Cardiology survey of cardiac resynchronisation therapy in 11 088 patients-who is doing what to whom and how?

Fecha de publicación:

Autores de IIS La Fe

Participantes ajenos a IIS La Fe

  • Dickstein, K
  • Normand, C
  • Auricchio, A
  • Bogale, N
  • Cleland, JG
  • Gitt, AK
  • Stellbrink, C
  • Anker, SD
  • Filippatos, G
  • Gasparini, M
  • Hindricks, G
  • Lundqvist, CB
  • Ponikowski, P
  • Ruschitzka, F
  • Botto, GL
  • Bulava, A
  • Duray, G
  • Israel, C
  • Leclercq, C
  • Margitfalvi, P
  • Plummer, C
  • Sarigul, NU
  • Sterlinski, M
  • Linde, C

Grupos

Abstract

Background Cardiac resynchronisation therapy (CRT) reduces morbidity and mortality in appropriately selected patients with heart failure and is strongly recommended for such patients by guidelines. A European Society of Cardiology (ESC) CRT survey conducted in 2008-2009 showed considerable variation in guideline adherence and large individual, national and regional differences in patient selection, implantation practice and follow-up. Accordingly, two ESC associations, the European Heart Rhythm Association and the Heart Failure Association, designed a second prospective survey to describe contemporary clinical practice regarding CRT. Methods and results A survey of the clinical practice of CRT-P and CRT-D implantation was conducted from October 2015 to December 2016 in 42 ESC member countries. Implanting centres provided information about their hospital and CRT service and were asked to complete a web-based case report form collecting information on patient characteristics, investigations, implantation procedures and complications during the index hospitalisation. The 11 088 patients enrolled represented 11% of the total number of expected implantations in participating countries during the survey period; 32% of patients were aged >= 75 years, 28% of procedures were upgrades from a permanent pacemaker or implantable cardioverter-defibrillator and 30% were CRT-P rather than CRT-D. Most patients (88%) had a QRS duration >= 130 ms, 73% had left bundle branch block and 26% were in atrial fibrillation at the time of implantation. Large geographical variations in clinical practice were observed. Conclusion CRT Survey II provides a valuable source of information on contemporary clinical practice with respect to CRT implantation in a large sample of ESC member states. The survey permits assessment of guideline adherence and demonstrates variations in patient selection, management, implantation procedure and follow-up strategy.

Datos de la publicación

ISSN/ISSNe:
1388-9842, 1879-0844

EUROPEAN JOURNAL OF HEART FAILURE  OXFORD UNIV PRESS

Tipo:
Article
Páginas:
1039-1051
PubMed:
29431254
Factor de Impacto:
5,537 SCImago ℠
Cuartil:
Q1 SCImago ℠

Citas Recibidas en Web of Science: 114

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Heart failure; Cardiac resynchronisation therapy; Demographics; Cardiac devices; Health care utilisation

Campos de Estudio

Cita

Compartir