Abstract
In this work, we present a new concept of IOL design inspired by the demonstrated properties of reduced chromatic aberration and extended depth of focus of Fractal zone plates. A detailed description of a proof of concept IOL is provided. The result was numerically characterized, and fabricated by lathe turning. The prototype was tested in vitro using dedicated optical system and software. The theoretical Point Spread Function along the optical axis, computed for several wavelengths, showed that for each wavelength, the IOL produces two main foci surrounded by numerous secondary foci that partially overlap each other for different wavelengths. The result is that both, the near focus and the far focus, have an extended depth of focus under polychromatic illumination. This theoretical prediction was confirmed experimentally by means of the Through-Focus Modulation Transfer Function, measured for different wavelengths.
Datos de la publicación
- ISSN/ISSNe:
- 1932-6203, 1932-6203
- Tipo:
- Article
- Páginas:
- -
- Factor de Impacto:
- 1,100 SCImago ℠
- Cuartil:
- Q1 SCImago ℠
Plos One PUBLIC LIBRARY SCIENCE
Citas Recibidas en Web of Science: 15
Documentos
- No hay documentos
Filiaciones
Keywords
- ZONE PLATES; CONTRAST SENSITIVITY; SPHERICAL-ABERRATION; DEVILS LENSES; IMAGE QUALITY; DEPTH
Campos de estudio
Proyectos asociados
ESTUDIO EN FASE II DE TAK-659 EN PACIENTES CON LINFOMA DIFUSO DE CÉLULAS B GRANDES RECIDIVANTE O RESISTENTE DESPUÉS DE DOS O MÁS LÍNEAS PREVIAS DE QUIMIOTERAPIA.
Investigador Principal: ISIDRO JARQUE RAMOS
C34004 . 2017
SEGURIDAD Y EFICACIA DE ABICIPAR PEGOL (AGN-150998) EN PACIENTES CON DEGENERACIÓN MACULAR NEOVASCULAR ASOCIADA A LA EDAD.
Investigador Principal: PATRICIA UDAONDO MIRETE
150998-005 . 2016
EFICACIA Y SEGURIDAD DEL BIMATOPROST DE LIBERACIÓN LENTA EN PACIENTES CON GLAUCOMA DE ÁNGULO ABIERTO O HIPERTENSIÓN OCULAR.
Investigador Principal: MERCEDES HURTADO SARRIÓ
192024-091 . 2015
ESTUDIO EPIDEMIOLÓGICO, PROSPECTIVO, MULTICÉNTRICO Y ABIERTO QUE EVALÚA LAS CARACTERÍSTICAS Y LA FRECUENCIA DE LA CONJUNTIVITIS ADENOVÍRICA DIAGNOSTICADA MEDIANTE EL TEST ADENOPLUS™ EN PACIENTES ENFERMOS DE CONJUNTIVITIS AGUDA. CÓDIGO ADVISE (ADENOVIRUS I NITIATIVE STUDY IN EPIDEMIOLOGY).
Investigador Principal: SALVADOR GARCÍA DELPECH
ADVISE . 2014
Cita
Remon L,Garcia S,Udaondo P,Ferrando V,Monsoriu JA,Furlan WD. Fractal-structured multifocal intraocular lens. PLoS One. 2018. 13. (7):e0200197. IF:2,776. (2).