Clinical outcomes of temporary mechanical circulatory support as a direct bridge to heart transplantation: a nationwide Spanish registry
Fecha de publicación:
Autores de IIS La Fe
Participantes ajenos a IIS La Fe
- Barge-Caballero, E
- Gonzalez-Vilchez, F
- Lambert-Rodriguez, JL
- Gonzalez-Costello, J
- Segovia-Cubero, J
- Castel-Lavilla, MA
- Delgado-Jimenez, J
- Garrido-Bravo, IP
- Rangel-Sousa, D
- Martinez-Selles, M
- De la Fuente-Galan, L
- Rabago-Juan-Aracil, G
- Sanz-Julve, M
- Hervas-Sotomayor, D
- Mirabet-Perez, S
- Muniz, J
- Crespo-Leiro, MG
Grupos
Abstract
Background In Spain, listing for high-urgent heart transplantation is allowed for critically ill candidates not weanable from temporary mechanical circulatory support (T-MCS). We sought to analyse the clinical outcomes of this strategy. Methods and results We conducted a case-by-case, retrospective review of clinical records of 291 adult patients listed for high-urgent heart transplantation under temporary devices from 2010 to 2015 in 16 Spanish institutions. Survival after listing and adverse clinical events were studied. At the time of listing, 169 (58%) patients were supported on veno-arterial extracorporeal membrane oxygenation (VA-ECMO), 70 (24%) on temporary left ventricular assist devices (T-LVAD) and 52 (18%) on temporary biventricular assist devices (T-BiVAD). Seven patients transitioned from VA-ECMO to temporary ventricular assist devices while on the waiting list. Mean time on T-MCS was 13.112.6days. Mean time from listing to transplantation was 7.6 +/- 8.5 days. Overall, 230 (79%) patients were transplanted and 54 (18.6%) died during MCS. In-hospital postoperative mortality after transplantation was 33.3%, 11.9% and 26.2% for patients bridged on VA-ECMO, T-LVAD and T-BiVAD, respectively (P = 0.008). Overall survival from listing to hospital discharge was 54.4%, 78.6% and 55.8%, respectively (P = 0.002). T-LVAD support was independently associated with a lower risk of death over the first year after listing (hazard ratio 0.52, 95% confidence interval 0.30-0.92). Patients treated with VA-ECMO showed the highest incidence rate of adverse clinical events associated with T-MCS. Conclusion Temporary devices may be used to bridge critically ill candidates directly to heart transplantation in a setting of short waiting list times, as is the case of Spain. In our series, bridging with T-LVAD was associated with more favourable outcomes than bridging with T-BiVAD or VA-ECMO.
Datos de la publicación
- ISSN/ISSNe:
- 1388-9842, 1879-0844
- Tipo:
- Article
- Páginas:
- 178-186
- DOI:
- 10.1002/ejhf.956
- PubMed:
- 28949079
- Factor de Impacto:
- 5,537 SCImago ℠
- Cuartil:
- Q1 SCImago ℠
EUROPEAN JOURNAL OF HEART FAILURE OXFORD UNIV PRESS
Citas Recibidas en Web of Science: 119
Documentos
- No hay documentos
Filiaciones
Keywords
- Ventricular assist device; Mechanical circulatory support; Heart transplantation; Extracorporeal membrane oxygenation
Portal de investigación