Spanish Pacemaker Registry. 14th Official Report of the Spanish Society of Cardiology Working Group on Cardiac Pacing (2016).

Fecha de publicación:

Autores de IIS La Fe

Participantes ajenos a IIS La Fe

  • Pombo Jiménez M
  • Fidalgo Andrés ML
  • Lorente Carreño D
  • Coma Samartín R

Grupos

Abstract

INTRODUCTION AND OBJECTIVES: This report describes the results of analysis of implanted pacemakers reported to the Spanish Pacemaker Registry. METHODS: The analysis was based on information provided by the European Pacemaker Identification Card. RESULTS: Information was received from 115 hospitals, with a total of 12 697 cards, representing 32.3% of the estimated activity. Use of conventional and resynchronization pacemakers was 818 and 79 units per million inhabitants, respectively. A total of 200 leadless pacemakers were implanted. The mean age of the patients receiving an implant was 77.8 years, and 52% of devices were implanted in persons older than 80 years. In all, 74.9% were first implants and 23.4% corresponded to generator exchange. Endocardial leads were bipolar, 82.9% with active fixation, and 16.1% had magnetic resonance imaging protection. Most patients received bicameral sequential pacing, although single chamber pacing VVI(R) was used in 26.7% of the patients with sick sinus syndrome and in 23.8% of those with atrioventricular block, despite sinus rhythm. CONCLUSIONS: Total use of pacemaker generators in Spain has increased by 1.6% compared with 2015. Most implanted leads have active fixation and less than 20% have magnetic resonance imaging protection. Age and sex directly influenced pacing mode selection, which could be improved in around 32% of patients.

Datos de la publicación

ISSN/ISSNe:
0300-8932, 1579-2242

REVISTA ESPANOLA DE CARDIOLOGIA  EDICIONES DOYMA S A

Tipo:
Article
Páginas:
1083-1097
Factor de Impacto:
0,553 SCImago
Cuartil:
Q2 SCImago

Citas Recibidas en Web of Science: 14

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Biventricular pacing; Cables marcapasos; Estimulacion biventricular; Marcapasos; Pacemaker leads; Permanent cardiac pacing; Registro; Registry

Campos de estudio

Proyectos asociados

INCORPORACIÓN GRUPOS CIBER. DR. DOLZ

Investigador Principal: LUIS VICENTE MARTÍNEZ DOLZ

CB16/11/00261 . INSTITUTO DE SALUD CARLOS III . 2017

MORE-CRT: EL AUMENTO DE LAS OPCIONES DISPONIBLES CON UN ELECTRODO VI TETRAPOLAR OFRECE SOLUCIONES CLÍNICAS A LOS PROBLEMAS DE LA TRC. MORE OPTIONS AVAILABLE WITH A QUADRIPOLAR LV LEAD PROVIDE IN CLINIC SOLUTIONS TO CRT CHALLENGES.

Investigador Principal: JOAQUÍN OSCA ASENSI

CR-11-006-HF-ID . 2012

GLORIA - AF: REGISTRO GLOBAL DEL TRATAMIENTO ANTITROMBÓTICO ORAL A LARGO PLAZO EN PACIENTES CON FIBRILACIÓN AURICULAR (FASE II/III – ESTADOS MIEMBROS DE LA UE/ AEE).

Investigador Principal: JOAQUÍN OSCA ASENSI

BOE-DAB-2012-01 . 2013

MORE RESPONSE ON CARDIAC RESYNCHRONIZATION THERAPY (CRT) WITH MULTIPOINT PACING (MPP) – MAYOR RESPUESTA A LA TERAPIA DE RESINCRONIZACIÓN CARDIACA (TRC) CON ESTIMULACIÓN MULTISITIO.

Investigador Principal: JOAQUÍN OSCA ASENSI

CR-13-006-ID-HF . 2013

ESTIMULACIÓN TRICAMERAL EN PACIENTES CON CARDIOMIOPATÍA HIPERTRÓFICA OBSTRUCTIVA. TRICHAMPION (TRIPLE CHAMBER PACING IN HOCM PATIENTS).

Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA

CR-11-030-EU-HF . 2014

INVESTIGACIÓN CLÍNICA SOBRE LAS DIFERENCIAS EN LA MAGNITUD DE LA RESPUESTA A LA TRC ENTRE HOMBRES Y MUJERES. (BIOWOMEN).

Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA

CR017 . 2015

ESTIMULACIÓN BIVENTRICULAR TRIFOCAL PARA LA OPTIMIZACIÓN DE LA TERAPIA DE RESINCRONIZACIÓN CARDIACA (TRC).

Investigador Principal: ÓSCAR CANO PÉREZ

ICSY02 . 2015

EVALUACIÓN CLÍNICA DEL PACIENTE Y FUNCIONAL DEL DISPOSITIVO EN LA PRÁCTICA CLÍNICA HABITUAL CON PORTADORES DE DAI.

Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA

RTSY03 . 2015

OPCIONES DE LA TERAPIA DE RESINCRONIZACIÓN CON EL ELECTRODO QUARTET TM (QUARTET LEAD AND RESYNCHRONIZATION THERAPY OPTIONS) III.

Investigador Principal: JOAQUÍN OSCA ASENSI

CRD_789 . 2015

REGISTRO DE ESTIMULACIÓN TRANSCATÉTER CON EL SISTEMA MICRATM (MICRA)

Investigador Principal: JOAQUÍN OSCA ASENSI

ESTUDIO MICRA PM . 2017

ESTIMULACIÓN SÍNCRONA MULTIPUNTO FRENTE A ESTIMULACIÓN SECUENCIAL MULTIPUNTO DEL VENTRÍCULO IZQUIERDO PARA TRC. ESTUDIO SYNSEQ.

Investigador Principal: JOAQUÍN OSCA ASENSI

ESTUDIO SYNSEQ . 2016

APNEA DE SUEÑO, ARRITMIAS Y REMODELADO CARDIACO INVERSO EN PACIENTES CON INSUFICIENCIA CARDIACA.

Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA

ICSY03 . 2017

EVALUACIÓN CLÍNICA DEL ALGORITMO DE AUTOUMBRAL DE VENTRÍCULO IZQUIERDO.

Investigador Principal: ÓSCAR CANO PÉREZ

IPTL01 . 2017

CONTROL ESTRATÉGICO PARA LA OPTIMIZACIÓN DE LA RESPUESTA A LA TERAPIA DE RESINCRONIZACIÓN CARDÍACA (STRATEGIC MANAGEMENT TO OPTIMIZE RESPONSE TO CARDIAC RESYNCHRONIZATION THERAPY) (SMART-CRT STUDY).

Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA

C2067 . 2017

ESTUDIO NAVIGATOR EVALUACIÓN DE SEGURIDAD Y EFICACIA ELÉCTRICA DE LOS CABLES NAVIGO CON CONECTOR IS4 (SAFETY AND ELECTRICAL PERFORMANCES EVALUATION NAVIGO LEADS EQUIPPED WITH IS4 CONNECTOR).

Investigador Principal: ÓSCAR CANO PÉREZ

LCPL01 . 2017

ANTICOAGULANTES ORALES NO ANTAGONISTAS DE LA VITAMINA K EN PACIENTES CON EPISODIOS DE FRECUENCIA AURICULAR RÁPIDA.

Investigador Principal: JOAQUÍN OSCA ASENSI

NOAH-AFNET6 . 2018

ESTUDIO OASIS-H. ORGANIZACION ASISTENCIAL DE PACIENTES CON HOME MONITORING.

Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA

OASIS-HM . 2010

ESTUDIO ABIERTO, FASE IV, MULTICÉNTRICO, PARA EVALUAR LA EFICACIA DIAGNÓSTICA DE NUUBO NECGBAND ANTES DEL HOLTER IMPLANTABLE.

Investigador Principal: ÓSCAR CANO PÉREZ

SYN201401 . 2015

ESTUDIO DE LA EFICACIA Y LA SEGURIDAD DE F373280 EN EL MANTENIMIENTO DEL RITMO SINUSAL TRAS CARDIOVERSIÓN ELÉCTRICA EN PACIENTES CON FIBRILACIÓN AURICULAR PERSISTENTE E INSUFICIENCIA CARDÍACA CRÓNICA. INTERNACIONAL, MULTICÉNTRICO, ALEATORIZADO, DOBLE CIEG O Y CONTROLADO CON PLACEBO.

Investigador Principal: JOAQUÍN OSCA ASENSI

F373280CA201

ESTUDIO OBSERVACIONAL PARA LA EVALUACIÓN DEL MANEJO DE PACIENTES RESINCRONIZADOS CON EL ELECTRODO TETRAPOLAR QUARTETTM DE VENTRÍCULO IZQUIERDO.

Investigador Principal: JOSE OLAGUE DE ROS

CR-12-015-SP-HF

REDUCCIÓN DE CHOQUES INAPROPIADOS CON EL DISCRIMINADOR DE RITMO PARAD+.

Investigador Principal: JOSE OLAGUE DE ROS

ITSY09

EVALUACIÓN NO INVASIVA DE LA ESTIMACIÓN DEL RIESGO POST-INFARTO - EFICACIA DE UN DAI.

Investigador Principal: JOAQUÍN OSCA ASENSI

REFINE_ICD

Cita

Compartir