Corneo-scleral contact lens in a piggyback system for keratoconus: A case report
Autores de IIS La Fe
Participantes ajenos a IIS La Fe
- Montalt, JC
Grupos
Abstract
Purpose: We describe a case of fitting a corneo-scleral contact lens with a multi-aspheric geometry design (MAGD CScL) on top of a daily silicone hydrogel lens (piggyback system) for keratoconus management. Methods: A 48-year-old man using soft toric contact lenses required an improvement in the unsatisfactory quality of his vision. He presented with bilateral asymmetric keratoconus with high myopia in the right eye (RE) and severe myopia in the left eye (LE). In addition, he had low vision in his LE because of a maculopathy. He was fitted with MAGD CScL to correct his irregular astigmatism. A diagnostic trial set was used in the fitting process and the patient was assessed according to a standardised fitting methodology. Visual acuity, corneal topography and contrast sensitivity were evaluated. The follow-up period was 1 year. Results: The best spectacle-corrected visual acuity was 0.5 logMAR for the RE with -10 D/-5 D x 60 degrees and 2 logMAR for the LE with -20 D/-3 D x 105 degrees. After fitting MAGD CScL, visual acuity improved significantly to 0.1 logMAR for the RE and 1.3 logMAR for the LE, as well as contrast sensitivity. The fitting parameters of the base curve, diameter, and power were 7.05 mm, 12.60 mm, -18.50 D and 7.15 mm, 12.60 mm, -19 D for the RE and LE, respectively. Optimal fitting characteristics were found in terms of lens position and lens movement. To increase the time of MAGD CScL wear, they piggybacked on daily silicone hydrogel lenses of low power (-0.5 D). The patient reported being comfortable with this piggyback system for approximately 15 h a day. After 1 year of using the piggyback system, visual quality and wearing time were maintained. In addition, no adverse ocular effects were found during this period. Conclusion: This case report shows that in this patient a MAGD CScL could be fitted successfully on a daily silicone hydrogel lens in a piggyback system for keratoconus management, providing good visual quality along with prolonged use times and without adverse effects on the cornea. (C) 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Datos de la publicación
- ISSN/ISSNe:
- 1367-0484, 1476-5411
- Tipo:
- Article
- Páginas:
- 190-194
- Factor de Impacto:
- 0,996 SCImago ℠
- Cuartil:
- Q1 SCImago ℠
CONTACT LENS & ANTERIOR EYE ELSEVIER SCIENCE BV
Citas Recibidas en Web of Science: 3
Documentos
- No hay documentos
Filiaciones
Keywords
- Corneal ectasia; Keratoconus; Corneo-scleral contact lens
Proyectos asociados
PATRONES DE RM CEREBRAL Y MEDULAR EN RELACION CON LA PRESENCIA DE AUTOANTIGENOS NEURONALES RECONOCIDOS POR INMUNOGLOBULINAS M PRESENTES EN EL LIQUIDO CEFALORRAQUIDEO DE PACIENTES DE ESCLEROSIS MULTIPLE.
Investigador Principal: ISABEL BOSCÁ BLASCO
MERCK SERONO DR. CASANOVA . ALMIRALL S.A; FUNDACIÓN BIOGEN IDEC; MERCK S.L.U; FUNDACIÓN PARA LA INVESTIGACIÓN DEL HOSPITAL UNIVERSITARIO LA FE DE LA COMUNIDAD VALENCIANA . 2010
RED ESPAÑOLA DE ESCLEROSIS MULTIPLE
RD12/0032/0019 . INSTITUTO DE SALUD CARLOS III; FUNDACIÓN PARA LA INVESTIGACIÓN DEL HOSPITAL UNIVERSITARIO LA FE DE LA COMUNIDAD VALENCIANA . 2012
FENOTIPO CLÍNICO Y FISIOPATOGENIA DE LOS PROCESOS DESMIELINIZANTES DEL SISTEMA NERVIOSO CENTRAL DEBIDOS A HIPERMUTACIONES SOMÁTICAS.
Investigador Principal: BONAVENTURA CASANOVA ESTRUCH
PI13/00663 . INSTITUTO DE SALUD CARLOS III . 2014
RED ESPAÑOLA DE ESCLEROSIS MÚLTIPLE.
Investigador Principal: BONAVENTURA CASANOVA ESTRUCH
RD16/0015/0015 . INSTITUTO DE SALUD CARLOS III . 2017
ESTUDIO MULTICÉNTRICO, ABIERTO, CON UN ÚNICO GRUPO QUE EVALÚA LA SEGURIDAD A LARGO PLAZO, LA TOLERABILIDAD Y LA EFICACIA DE FINGOLIMOD 0,5 MG (FTY720) ADMINISTRADO POR VÍA ORAL UNA VEZ AL DÍA EN PACIENTES CON ESCLEROSIS MÚLTIPLE.
Investigador Principal: BONAVENTURA CASANOVA ESTRUCH
CFTY720D2399 . 2010
ESTUDIO MULTICÉNTRICO, ALEATORIZADO, DOBLE CIEGO, DE GRUPOS PARALELOS, CONTROLADO CON PLACEBO, CON DURACIÓN VARIABLE DEL TRATAMIENTO, QUE EVALÚA LA EFICACIA Y SEGURIDAD DE SIPONIMOD (BAF312) EN PACIENTES CON ESCLEROSIS MÚLTIPLE SECUNDARIA PROGRESIVA SEGUIDO POR UNA EXTENSIÓN DEL TRATAMIENTO EN ABIERTO DE BAF312.
Investigador Principal: BONAVENTURA CASANOVA ESTRUCH
CBAF312A2304 . 2013
ESTUDIO DE FASE III, ALEATORIZADO, ABIERTO QUE COMPARA LA COMBINACIÓN DEL INHIBIDOR DE BRAF, (DABRAFENIB) Y EL INHIBIDOR DE MEK (TRAMETINIB), CON EL INHIBIDOR DE BRAF (VEMURAFENIB) EN PACIENTES CON MELANOMA CUTÁNEO NO RESECABLE (ESTADIO IIIC) O METASTÁSIC O (ESTADIO IV) CON LA MUTACIÓN BRAF V600E/K.
Investigador Principal: ROBERTO PEDRO DÍAZ BEVERIDGE
MEK116513
ENSAYO CLINICO FASE III, DE GRUPOS PARALELOS, RANDOMIZADO, CONTROLADO CON PLACEBO, DOBLE CIEGO Y MULTICENTRICO, PARA EVALUAR LA EFICACIA Y SEGURIDAD DE LA ADMINISTRACION DE TOCILIZUMAB EN PACIENTES DIAGNOSTICADOS DE ORBITOPATÍA TIROIDEA (OT) MODERADA A SE VERA O QUE AMENAZA LA VISTA, QUE NO HAN RESPONDIDO ADECUADAMENTE AL TRATAMIENTO CON PULSOS DE CORTICOIDES.
Investigador Principal: ENRIQUE ESPAÑA GREGORI
GRC-TCL-2010-01 . 2013
ESTUDIO ALEATORIZADO, DOBLE CIEGO, EN GRUPOS PARALELOS, CONTROLADO CON PLACEBO PARA EVALUAR LA EFICACIA, SEGURIDAD, TOLERABILIDAD Y FARMACOCINÉTICA DE BIIB033 EN SUJETOS CON EL PRIMER EPISODIO DE NEURITIS ÓPTICA AGUDA.
Investigador Principal: BONAVENTURA CASANOVA ESTRUCH
215ON201
ESTUDIO MULTICÉNTRICO DE TRES AÑOS DE DURACIÓN PARA EVALUAR LA TOMOGRAFÍA DE COHERENCIA ÓPTICA COMO MEDIDA DE VALORACIÓN EN PACIENTES CON ESCLEROSIS MÚLTIPLE.
Investigador Principal: BONAVENTURA CASANOVA ESTRUCH
CFTY720D2319 . 2012
ESTUDIO OBSERVACIONAL, PROSPECTIVO Y MULTICÉNTRICO EN CUIDADOS INTENSIVOS PARA EVALUAR LA FIABILIDAD DIAGNÓSTICOA DE LA PCR (REACCIÓN EN CADENA DE LA POLIMERASA) EN PACIENTES EN TRATAMIENTO ANTIFÚNGICO EMPÍRICO POR SOSPECHA DE CANDIDIASIS INVASIVA. (ESTUD IO MICAFEM).
Investigador Principal: PAULA RAMÍREZ GALLEYMORE
AST-INF-2012-01
ESTUDIO FASE 2/3, MULTICÉNTRICO, ALEATORIZADO, DOBLE CIEGO, CONTROLADO CON PLACEBO (PARTE A) Y DOBLE CIEGO, CON DOBLE SIMULACIÓN Y CON CONTROL ACTIVO (PARTE B), DE GRUPOS PARALELOS PARA EVALUAR LA EFICACIA Y LA SEGURIDAD DE RPC1063 ADMINISTRADO POR VÍA OR AL A PACIENTES CON ESCLEROSIS MÚLTIPLE RECIDIVANTE.
Investigador Principal: BONAVENTURA CASANOVA ESTRUCH
RPC01-201
Cita
Porcar E,Montalt JC,España E,Peris C. Corneo-scleral contact lens in a piggyback system for keratoconus: A case report. Contact Lens Anterior Eye. 2017. 40. (3):p. 190-194. IF:1,865. (3).