Accurate simultaneous quantification of liver steatosis and iron overload in diffuse liver diseases with MRI

Fecha de publicación:

Autores de IIS La Fe

Participantes ajenos a IIS La Fe

  • França M
  • Oliveira, P
  • Costa, FE
  • Porto, G
  • Vizcaino, JR
  • Gonzalez, JS
  • Ribeiro, E
  • Oliveira, J
  • Pessegueiro Miranda H

Grupos

Abstract

Purpose: To evaluate the diagnostic performances of 3 Tesla multi-echo chemical shift-encoded gradient echo magnetic resonance (MECSE-MR) imaging to simultaneously quantify liver steatosis and iron overload in a wide spectrum of diffuse liver diseases having biopsy as reference standard. Methods: MECSE-MR-acquired images were used to calculate fat fraction and iron content in a single breath-hold in 109 adult patients. Proton density fat fraction (PDFF) was prospectively estimated using complex-based data reconstruction with multipeak fat modeling. Water R2* was used to estimate iron content. Biopsy was obtained in all cases, grading liver steatosis, siderosis, inflammation, and fibrosis. Differences in PDFF and R2* values across histopathological grades were analyzed, and ROC curves analyses evaluated the MR diagnostic performance. Results: Calculated fat fraction measurements showed significant differences (p < 0.001) among steatosis grades, being unaffected by the presence of inflammation or fibrosis (p >= 0.05). A strong correlation was found between fat fraction and steatosis grade (R-S = 0.718, p < 0.001). Iron deposits did not affect fat fraction quantitation (p >= 0.05), except in cases with severe iron overload (grade 4). A strong positive correlation was also observed between R2* measurements and iron grades (R-S = 0.704, p < 0.001). Calculated R2* values were not different across grades of steatosis, inflammation, and fibrosis (p >= 0.05). Conclusions: A MECSE-MR sequence simultaneously quantifies liver steatosis and siderosis, regardless coexisting liver inflammation or fibrosis, with high accuracy in a wide spectrum of diffuse liver disorders. This sequence can be acquired within a single breath-hold and can be implemented in the routine MR evaluation of the liver.

Datos de la publicación

ISSN/ISSNe:
2366-004X, 2366-0058

Abdominal Radiology  SPRINGER

Tipo:
Article
Páginas:
1434-1443
PubMed:
28110367
Factor de Impacto:
0,866 SCImago ℠
Cuartil:
Q2 SCImago ℠

Citas Recibidas en Web of Science: 51

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Fat quantification; Iron overload; R2*measurement; Chronicliver diseases; Quantitative imaging biomarkers

Cita

Compartir