Conduction System Versus Right Ventricular Pacing in Patients Undergoing TAVR
Autores de IIS La Fe
Participantes ajenos a IIS La Fe
- Diez-Delhoyo F.
- Muntane-Carol G.
- Amat-Santos I.J.
- Oteo Dominguez J.F.
- Rivera-Lopez R.
- Asmarats L.
- Pan M.
- Novoa Medina J.M.
- Franco-Pelaez J.A.
- Cuellas C.
- Roa-Garrido J.
- Tamargo M.
- Veiga G.
- Herrero-Brocal M.
- Valentin Garcia P.M.
- Garcia-Lara J.
- Cuesta J.
- Valencia-Serrano F.
- Pimienta-Gonzalez R.
- Linares Vicente J.A.
- Palazuelos-Molinero J.
- Gomez-Blazquez I.
- Di Marco A.
- Garnacho-Gomez L.
- Vela-Martin P.
- Martin-Arriscado C.
- Cebada F.S.
Grupos
Abstract
Background Pacemaker implantation after transcatheter aortic valve replacement (TAVR) is common and has been associated with adverse clinical outcomes. Cardiac physiological pacing (CPP) may preserve ventricular synchrony and reduce heart failure (HF) events compared with right ventricular pacing (RVP). Objectives This study sought to compare long-term clinical outcomes of CPP vs RVP in patients requiring permanent pacing after TAVR. Methods Registro de Estimulación Fisiológica-TAVR is a retrospective, multicenter nationwide registry including patients undergoing TAVR and pacemaker implantation within 30 days. Propensity score matching (1:1) was performed using baseline clinical and echocardiographic variables, yielding 466 matched pairs. The primary endpoint was the composite of cardiovascular death or HF hospitalization. Cox proportional hazards models were used for time-to-event analyses. Median follow-up was 24 months. Results In the propensity score–matched cohort, CPP was associated with a lower incidence of the primary endpoint than RVP (9.7% vs 17.6%; HR: 0.57; 95% CI: 0.39-0.83; P = 0.003). This difference was driven by fewer HF hospitalizations (7.9% vs 13.9%; HR: 0.57; 95% CI: 0.37-0.86; P = 0.008). No significant differences were observed in cardiovascular death or all-cause mortality between groups. Conclusions In this multicenter propensity score–matched study, CPP after TAVR was associated with a lower risk of the primary endpoint, driven by fewer HF hospitalizations. These findings support the need for further randomized clinical trials to evaluate the role of CPP in post-TAVR patients requiring ventricular pacing. © 2026 American College of Cardiology Foundation.
Datos de la publicación
- ISSN/ISSNe:
- 1936-8798, 1876-7605
- Tipo:
- Article
- Páginas:
- 2635-2647
- PubMed:
- 42863877
- Enlace a otro recurso:
- www.scopus.com
- Factor de Impacto:
- 3,595 SCImago ℠
- Cuartil:
- Q1 SCImago ℠
JACC-Cardiovascular Interventions ELSEVIER SCIENCE INC
Citas Recibidas en Scopus: 1
Documentos
- No hay documentos
Filiaciones
Keywords
- Aged; Aged, 80 and over; Aortic Valve Stenosis; Cardiac Pacing, Artificial; Female; Heart Conduction System; Heart Failure; Hospitalization; Humans; Male; Pacemaker, Artificial; Propensity Score; Proportional Hazards Models; Registries; Retrospective Studies; Risk Factors; Time Factors; Transcatheter Aortic Valve Replacement; Treatment Outcome; Ventricular Function, Right; aged; all cause mortality; Article; clinical outcome; controlled study; female; heart failure; heart ventricle pacing; hospitalization; human; intermethod comparison; major clinical study; male; multicenter study; pacemaker implantation; propensity score; retrospective study; transcatheter aortic valve implantation; very elderly; adverse event; aortic valve stenosis; artificial heart pacemaker; clinical trial; comparative study; diagnosis; diagnostic imaging; etiology; heart failure; heart muscle conduction system; heart pacing; heart right ventricle function; mortality; pathophysiology; prevention and control; proce
Cita
Diez F,SANZ J,Muntane G,Amat IJ,Oteo JF,Rivera R,Asmarats L,Pan M,Novoa JM,Franco JA,Cuellas C,Roa J,Tamargo M,Veiga G,Herrero M,Valentin PM,Garcia J,Cuesta J,Valencia F,Pimienta R,Linares JA,Palazuelos J,Gomez I,NAVARRO J,Di A,Garnacho L,Vela P,Martin C,Cebada FS. Conduction System Versus Right Ventricular Pacing in Patients Undergoing TAVR. JACC Cardiovasc. Interventions. 2026. 19. (19):p. 2635-2647. IF:12,700. (1).
Portal de investigación