Radiofrequency current-facilitated implantation of left bundle branch pacing lead for cardiac resynchronization therapy

Fecha de publicación:

Autores de IIS La Fe

Participantes ajenos a IIS La Fe

  • Jastrzebski M.
  • Shah R.
  • Bednarek A.
  • Sondej T.
  • Kielbasa G.
  • Moskal P.
  • Atallah R.
  • Vernooy K.
  • Rajzer M.
  • Vijayaraman P.

Grupos

Abstract

BACKGROUND: Fibrosis within the interventricular septum hinders the implantation of left bundle branch pacing (LBBP) lead, particularly in candidates for cardiac resynchronization therapy (CRT). OBJECTIVE: This study aimed to report the acute and follow-up outcomes of pacing lead implantation using radiofrequency (RF) current delivered to the lead tip for septal electrosection in challenging LBBP cases. METHODS: Data on lead deployment success, RF power and delivery time, complications, lead stability, proarrhythmia, current of injury, and pacing parameters were collected acutely and at the final follow-up. RESULTS: A total of 37 RF-facilitated lead implantations in 36 patients (average age 71.6 ± 8.8 years), most of whom were CRT eligible (89%), were analyzed. On average, 2.1 ± 1.7 RF applications (resulting in 2.6 ± 2.2 seconds of RF) were used per implantation with a median power of 27 W. RF delivery was used in 85.7% of cases to achieve a current of injury drop that could not be obtained with manual lead rotation alone. Lead implantation was successful in all but 2 cases. The mean follow-up duration was 236 ± 165 days. Lead performance, including pacing parameters and lead stability, was good and did not seem to be affected by RF use (follow-up threshold 0.8 ± 0.3 V; sensitivity: 12.0 ± 5.6 mV). 1 patient experienced sustained ventricular tachycardia, and in all other cases, proarrhythmia was absent or self-limited. No other complications were noted. CONCLUSION: RF-facilitated LBBP lead implantation is a feasible technique with potential cautious use as a bailout in selected cases, especially for failed CRT delivery. Copyright © 2026 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

Datos de la publicación

ISSN/ISSNe:
1547-5271, 1556-3871

HEART RHYTHM  ELSEVIER SCIENCE INC

Tipo:
Article
Páginas:
2060-2068
PubMed:
41966386
Enlace a otro recurso:
www.scopus.com
Factor de Impacto:
2,402 SCImago ℠
Cuartil:
Q1 SCImago ℠

Citas Recibidas en Scopus: 2

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Aged; Bundle of His; Bundle-Branch Block; Cardiac Resynchronization Therapy; Cardiac Resynchronization Therapy Devices; Electrocardiography; Female; Follow-Up Studies; Heart Failure; Humans; Male; Retrospective Studies; Treatment Outcome; aged; cardiac resynchronization therapy; cardiac resynchronization therapy device; electrocardiography; female; follow up; heart bundle branch block; heart failure; His bundle; human; male; pathophysiology; procedures; retrospective study; therapy; treatment outcome

Cita

Compartir