Radiofrequency current-facilitated implantation of left bundle branch pacing lead for cardiac resynchronization therapy
Fecha de publicación:
Autores de IIS La Fe
Participantes ajenos a IIS La Fe
- Jastrzebski M.
- Shah R.
- Bednarek A.
- Sondej T.
- Kielbasa G.
- Moskal P.
- Atallah R.
- Vernooy K.
- Rajzer M.
- Vijayaraman P.
Grupos
Abstract
BACKGROUND: Fibrosis within the interventricular septum hinders the implantation of left bundle branch pacing (LBBP) lead, particularly in candidates for cardiac resynchronization therapy (CRT). OBJECTIVE: This study aimed to report the acute and follow-up outcomes of pacing lead implantation using radiofrequency (RF) current delivered to the lead tip for septal electrosection in challenging LBBP cases. METHODS: Data on lead deployment success, RF power and delivery time, complications, lead stability, proarrhythmia, current of injury, and pacing parameters were collected acutely and at the final follow-up. RESULTS: A total of 37 RF-facilitated lead implantations in 36 patients (average age 71.6 ± 8.8 years), most of whom were CRT eligible (89%), were analyzed. On average, 2.1 ± 1.7 RF applications (resulting in 2.6 ± 2.2 seconds of RF) were used per implantation with a median power of 27 W. RF delivery was used in 85.7% of cases to achieve a current of injury drop that could not be obtained with manual lead rotation alone. Lead implantation was successful in all but 2 cases. The mean follow-up duration was 236 ± 165 days. Lead performance, including pacing parameters and lead stability, was good and did not seem to be affected by RF use (follow-up threshold 0.8 ± 0.3 V; sensitivity: 12.0 ± 5.6 mV). 1 patient experienced sustained ventricular tachycardia, and in all other cases, proarrhythmia was absent or self-limited. No other complications were noted. CONCLUSION: RF-facilitated LBBP lead implantation is a feasible technique with potential cautious use as a bailout in selected cases, especially for failed CRT delivery. Copyright © 2026 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Datos de la publicación
- ISSN/ISSNe:
- 1547-5271, 1556-3871
- Tipo:
- Article
- Páginas:
- 2060-2068
- PubMed:
- 41966386
- Enlace a otro recurso:
- www.scopus.com
- Factor de Impacto:
- 2,402 SCImago ℠
- Cuartil:
- Q1 SCImago ℠
HEART RHYTHM ELSEVIER SCIENCE INC
Citas Recibidas en Scopus: 2
Documentos
- No hay documentos
Filiaciones
Keywords
- Aged; Bundle of His; Bundle-Branch Block; Cardiac Resynchronization Therapy; Cardiac Resynchronization Therapy Devices; Electrocardiography; Female; Follow-Up Studies; Heart Failure; Humans; Male; Retrospective Studies; Treatment Outcome; aged; cardiac resynchronization therapy; cardiac resynchronization therapy device; electrocardiography; female; follow up; heart bundle branch block; heart failure; His bundle; human; male; pathophysiology; procedures; retrospective study; therapy; treatment outcome
Cita
Jastrzebski M,Shah R,Bednarek A,CANO O,Sondej T,Kielbasa G,Moskal P,Atallah R,Vernooy K,Rajzer M,Vijayaraman P. Radiofrequency current-facilitated implantation of left bundle branch pacing lead for cardiac resynchronization therapy. Heart Rhythm. 2026. 23. (9):p. 2060-2068. IF:7,000. (1).