Abstract

Introduction and objectives: This article reports the cardiac pacing activity performed in 2022, including the total number of implants, adherence to remote monitoring, demographic and clinical factors, and the characteristics of the implanted devices. Methods: The information sources were the CardioDispositivos online platform, the European pacemaker patient identification card, and data provided by the manufacturers. Results: The rates of conventional pacemakers and low-energy resynchronizers were 866 and 34 units per million population, respectively. A total of 815 leadless pacemakers were implanted. In all, 16426 procedures performed in 82 hospitals were reported (9407 through CardioDispositivos), representing 40% of the activity. The mean age was 78.6 years, with a predominance of men (60.3%). The most frequent disorder was atrioventricular block, and 14.5% of the patients had atrial fibrillation. There was a predominance of the DDD/R pacing mode (55.6%), and pacing mode was influenced by age, such that more than one-third of patients older than 80 years in sinus rhythm received single-chamber ventricular pacing. The remote monitoring program included 35% of conventional pacemakers and 55% of low-energy resynchronization pacemakers. Conclusions: The number of conventional pacemakers increased by 5.6%, low-energy resynchronizers by 16%, and leadless pacemakers by 25%. Adherence to remote monitoring was stable. The number of procedures included in CardioDispositivos increased by 11%, although the sample volume decreased. In the coming years, the widespread use of the platform will likely lead to a high-quality registry. © 2023 Sociedad Española de Cardiología

Datos de la publicación

ISSN/ISSNe:
0300-8932, 1579-2242

REVISTA ESPANOLA DE CARDIOLOGIA  EDICIONES DOYMA S A

Tipo:
Article
Páginas:
1032-1041
PubMed:
37852369
Enlace a otro recurso:
www.scopus.com
Factor de Impacto:
0,407 SCImago ℠
Cuartil:
Q3 SCImago ℠

Citas Recibidas en Web of Science: 9

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Aged; Aged, 80 and over; Atrial Fibrillation; Cardiac Pacing, Artificial; Cardiology; Female; Humans; Male; Pacemaker, Artificial; Registries; Societies, Medical; aged; Article; atrial fibrillation; atrioventricular block; cardiology; female; heart pacing; heart rhythm; human; major clinical study; male; patient identification; remote sensing; sinus rhythm; atrial fibrillation; heart pacing; medical society; register; very elderly

Campos de Estudio

Compartir