Development and evaluation of two open-source nnU-Net models for automatic segmentation of lung tumors on PET and CT images with and without respiratory motion compensation

Fecha de publicación: Fecha Ahead of Print:

Autores de IIS La Fe

Participantes ajenos a IIS La Fe

  • Kuhn, D
  • Fechter, T
  • Baltas, D
  • Mix, M
  • Nestle, U
  • Grosu, AL
  • Radicioni, G
  • Gkika, E

Grupos

Abstract

Objectives In lung cancer, one of the main limitations for the optimal integration of the biological and anatomical information derived from Positron Emission Tomography (PET) and Computed Tomography (CT) is the time and expertise required for the evaluation of the different respiratory phases. In this study, we present two open-source models able to automatically segment lung tumors on PET and CT, with and without motion compensation. Materials and methods This study involved time-bin gated (4D) and non-gated (3D) PET/CT images from two prospective lung cancer cohorts (Trials 108237 and 108472) and one retrospective. For model construction, the ground truth (GT) was defined by consensus of two experts, and the nnU-Net with 5-fold cross-validation was applied to 560 4D-images for PET and 100 3D-images for CT. The test sets included 270 4D- images and 19 3D-images for PET and 80 4D-images and 27 3D-images for CT, recruited at 10 different centres. Results In the performance evaluation with the multicentre test sets, the Dice Similarity Coefficients (DSC) obtained for our PET model were DSC(4D-PET)=0.740.06, improving 19% relative to the DSC between experts and DSC(3D-PET)=0.820.11. The performance for CT was DSC(4D-CT)=0.610.28 and DSC(3D-CT)=0.630.34, improving 4% and 15% relative to DSC between experts. Conclusions Performance evaluation demonstrated that the automatic segmentation models have the potential to achieve accuracy comparable to manual segmentation and thus hold promise for clinical application. The resulting models can be freely downloaded and employed to support the integration of 3D- or 4D- PET/CT and to facilitate the evaluation of its impact on lung cancer clinical practice.

Datos de la publicación

ISSN/ISSNe:
0938-7994, 1432-1084

EUROPEAN RADIOLOGY  SPRINGER

Tipo:
Article
Páginas:
6701-6711
PubMed:
38662100
Factor de Impacto:
1,730 SCImago ℠
Cuartil:
Q1 SCImago ℠

Citas Recibidas en Web of Science: 21

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Lung cancer; Positron emission tomography; Computed tomography; Deep learning; Respiratory motion

Cita