Multimodal PET-MR segmentation for glioblastoma: complementarity for treatment planning and recurrence definition.
Fecha de publicación:
Fecha Ahead of Print:
Autores de IIS La Fe
Participantes ajenos a IIS La Fe
- Kuhn D
- Fechter T
- Mauer M
- Fostitsch J
- Mix M
- Baltas D
- Grosu AL
- Popp I
Grupos
Abstract
BACKGROUND: In patients with Glioblastoma (GBM), Magnetic Resonance (MR) is used for tumour diagnosis and treatment planning. Positron Emission Tomography (PET) with O-(2)-18 F-Fluoroethyl-L-Tyrosine (FET) has been recommended to distinguish local recurrence from radiogenic alterations. However, clinical practice remains hindered by the time and expertise required for tumour and organs-at-risk (OARs) segmentation and the limited evidence of the added value of PET and its restricted availability across clinical centres. This study presents automatic segmentation models and a comprehensive evaluation of PET/MR complementary biological information for recurrent disease definition. METHODS: The nnU-Net was employed for segmentation using manually defined contours on 1,610 patients from 33 institutions. Model performance was evaluated by Dice-Sørensen-Coefficient (DSC). PET/MR recurrence complementarity was evaluated in 185 patients by Wilcoxon-Signed-Rank test (WSRT), DSC and radiomic features (RF). In RF analysis, MR-Enhancing subregions were classified as MRnPET or MR-Only, based on overlap with PET. For MR-RF showing significant MRnPET/MR-Only differences (WSRT), discrimination was further assessed by classifying RF for 3 × 3 × 3-voxel subregions within MR-Enhancing in two volumes (greater/less than the RF cohort median) and evaluating Positive-Predictive-Value and Sensitivity with MRnPET/MR-Only. RESULTS: Models' performance in the test set resulted in DSC(MR-Enhancing) = 0.76 ± 0.24, DSC(MR-Edema) = 0.69 ± 0.23, DSC(PET-Uptake) = 0.71 ± 0.20, DSC(Planning-Target-Volume) = 0.93 ± 0.05, DSC(OARs) = 0.70 ± 0.13. Manual MR and FET-PET based GBM recurrence delineations differed significantly in size (p = 0.0497) and location (DSC = 0.45 ± 0.20). From the 37 MR-RF showing significant differences between MRnPET and MR-Only (p < 0.05), none of the MR-Enhancing based RF-maps allowed spatial identification of PET findings (positive-predictive-value and sensitivity < 0.6). CONCLUSIONS: The resulted segmentation models could facilitate PET/MR integration in GBM treatment. PET/MR comparison supports the complementarity of FET-PET.
© 2026. The Author(s).
Datos de la publicación
- ISSN/ISSNe:
- 1740-5025, 1470-7330
- Tipo:
- Article
- Páginas:
- -
- PubMed:
- 42477719
- Factor de Impacto:
- 1,076 SCImago ℠
- Cuartil:
- Q1 SCImago ℠
CANCER IMAGING BMC
Documentos
- No hay documentos
Filiaciones
Keywords
- Convolutional neural network; Glioblastoma; Radiation oncology; Radiomics; Segmentation