Evaluation of a PET Insert for Trimodal Imaging: A Step Toward PET/MRI-Guided Focused Ultrasound
Fecha de publicación:
Autores de IIS La Fe
Participantes ajenos a IIS La Fe
- Lopez-Berenguer F.
- Gonzalez-Montoro A.
- Freire M.
- Gonzalez-Tamarit A.
- Jimenez-Serrano S.
- Vidal L.F.
- Gil M.
- Loignon-Houle F.
- Sachs J.L.
- Rispoli J.V.
- Tustison N.
- Berr S.S.
- Williams M.B.
- Andres D.
- Rodriguez-Garcia J.J.
- Alonso-Ramos J.L.
- Jimenez N.
- Carrion A.
- Camarena F.
- Guallart-Naval T.
- Algarin J.M.
- Bosch R.
- Pallas E.
- Alonso J.
- Sheybani N.D.
- Maslova S.
- Sherlock T.
- Thede A.
- Demir Z.E.F.
- Hoch M.
- He J.
- Benlloch J.M.
- Rodriguez-Alvarez M.J.
- Gonzalez A.J.
Grupos
Abstract
Combining positron emission tomography (PET) with magnetic resonance imaging (MRI) and focused ultrasound (FUS) has emerged as a promising hybrid technique in the medical imaging field. Despite the potential benefits of using simultaneous PET and MRI acquisitions to monitor therapeutic effects and ensure precision and safety during FUS applications, no commercial or academic PET/MRI-guided FUS system (referred in the following as trimodal PET-MRI-FUS) exists. This work presents the design and evaluation of a preclinical PET insert for simultaneous operation with MRI and FUS systems. The proposed PET insert is based on monolithic LYSO crystals arranged in two octagonal rings that define inner and outer diameters of 72 and 114 mm, respectively, with an axial length of 67 mm. The system performance was evaluated according to the NEMA NU 4 2008 protocol. It achieves a uniform spatial resolution of ~0.9 mm along the whole PET Field of View (FOV) when enabling Depth of Interaction (DOI) capabilities. Moreover, we found a sensitivity peak of 3.8% for an energy window of 255-766 keV and a peak noise equivalent count rate peak of 80 kcps at an activity of 19 MBq. The compatibility of the PET insert with both low- and high-field MRI systems, as well as with custom and commercially available FUS devices, was studied using phantoms and in vivo experiments, respectively. The results of the trimodal tests have proven that the PET insert works simultaneously with both MRI and FUS systems. © 2025 IEEE.
Datos de la publicación
- ISSN/ISSNe:
- 2469-7311, 2469-7303
- Tipo:
- Article
- Páginas:
- 789-798
- PubMed:
- 42147801
- Enlace a otro recurso:
- www.scopus.com
- Factor de Impacto:
- 1,004 SCImago ℠
- Cuartil:
- Q1 SCImago ℠
IEEE Transactions on Radiation and Plasma Medical Sciences IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Citas Recibidas en Web of Science: 1
Citas Recibidas en Scopus: 1
Documentos
- No hay documentos
Filiaciones
Keywords
- Intelligent systems; Magnetic resonance imaging; Medical imaging; Positrons; Emission tomography; Focused ultrasound; Hybrid techniques; Imaging/ultrasound; Magnetic resonance imaging; Positron emission; Positron emission tomography; Trimodal imaging; Ultrasound system; Positron emission tomography
Cita
Lopez F,Gonzalez A,Freire M,Gonzalez A,Jimenez S,Vidal LF,Gil M,Loignon F,TORRES I,Sachs JL,Rispoli JV,Tustison N,Berr SS,Williams MB,Andres D,Rodriguez JJ,Alonso JL,Jimenez N,Carrion A,Camarena F,Guallart T,Algarin JM,Bosch R,Pallas E,Alonso J,Sheybani ND,Maslova S,Sherlock T,Thede A,Demir ZEF,Hoch M,He J,Benlloch JM,Rodriguez MJ,Gonzalez AJ. Evaluation of a PET Insert for Trimodal Imaging: A Step Toward PET/MRI-Guided Focused Ultrasound. IEEE Trans. Radiat. Plasma Med. Sci. 2026. 10. (5):p. 789-798. IF:3,800. (1).
Portal de investigación