Validation of 2 Prognostic Models to Predict Renal Allograft Outcome After IgA Nephropathy Recurrence.
Fecha de publicación:
Fecha Ahead of Print:
Autores de IIS La Fe
Participantes ajenos a IIS La Fe
- Rodrigo E
- Quintana LF
- Vázquez-Sánchez T
- Sánchez-Fructuoso A
- Buxeda A
- Gavela E
- Cazorla JM
- Cabello S
- Sevillano AM
- López-Oliva MO
- Diekmann F
- Gómez-Ortega JM
- Calvo-Romero N
- Pérez-Sáez MJ
- Sancho A
- Mazuecos A
- Trujillo H
- Jiménez C
- Hernández D
Abstract
INTRODUCTION: IgA nephropathy (IgAN) recurrence (IgANr) after kidney transplantation (KTx) is common and contributes to reducing graft survival. Some tools have been developed to predict the patients who are at a higher risk of poor outcomes among the native (international IgAN prediction tool [IIgAN-PT]) and graft (Bednarova's prediction tool [Bednarova-PT]) kidney. We aimed to analyze their performance in a KTx population other than the originally reported. METHODS: We performed a multicenter retrospective study including KTx with biopsy-proven IgANr. IIgAN-PT and Bednarova-PT were used to calculate the risk of death-censored graft loss (DCGL). We assessed the performance of both prediction models using discrimination and calibration metrics and Kaplan-Meier plots. RESULTS: One hundred twenty KTx with IgANr were included. The time-dependent receiver operating characteristic (ROC) area under the curve (AUC) of Bednarova-PT for predicting DCGL was 83.5 (95% CI: 72.3-94.7) and the calibration slope was 0.96 (95% CI: 0.37-1.49). The time-dependent ROC AUC of IIgAN-PT for predicting DCGL was 87.3 (95% CI: 77.58-97.02) and the calibration slope was 2.49 (95% CI: 0.19-4.13). IIgAN-PT tended to underestimate the graft-loss risk in high-risk individuals. The Kaplan-Meier curve of the highest risk group, defined by using both prediction tools, was clearly separated from the other curves. CONCLUSION: Both IIgAN-PT and Bednarova-PT performed well in predicting DCGL after IgANr and should be used to identify those KTx at the highest risk. Both models had good discriminatory ability and were well-calibrated, although the calibration slope was higher for IIgAN-PT, tending to underestimate the risk in high-risk individuals.
© 2025 International Society of Nephrology. Published by Elsevier Inc.
Datos de la publicación
- ISSN/ISSNe:
- 2468-0249, 2468-0249
- Tipo:
- Article
- Páginas:
- 2323-2333
- PubMed:
- 40677345
- Enlace a otro recurso:
- www.scopus.com
- Factor de Impacto:
- 1,239 SCImago ℠
- Cuartil:
- Q1 SCImago ℠
Kidney International Reports ELSEVIER SCIENCE INC
Documentos
- No hay documentos
Filiaciones
Keywords
- IgA nephropathy; crescents; graft loss; inflammation; kidney transplantation; prediction tools; recurrence
Cita
Rodrigo E,Quintana LF,Vázquez T,Sánchez A,Buxeda A,Gavela E,Cazorla JM,Cabello S,BENEYTO I,Sevillano AM,López MO,Diekmann F,Gómez JM,Calvo N,Pérez MJ,Sancho A,Mazuecos A,ESPÍ J,Trujillo H,Jiménez C,Hernández D. Validation of 2 Prognostic Models to Predict Renal Allograft Outcome After IgA Nephropathy Recurrence. Kidney Int. Rep. 2025. 10. (7):p. 2323-2333. IF:6,200. (1).
Portal de investigación