Detection of clinically relevant variants in the TP53 gene below 10% allelic frequency: A multicenter study by ERIC, the European Research Initiative on CLL
Fecha de publicación:
Fecha Ahead of Print:
Autores de IIS La Fe
Participantes ajenos a IIS La Fe
- Pavlova, S
- Malcikova, J
- Radova, L
- Bonfiglio, S
- Cowland, JB
- Brieghel, C
- Andersen, MK
- Karypidou, M
- Biderman, B
- Doubek, M
- Lazarian, G
- Rapado, I
- Vynck, M
- Porret, NA
- Andres, M
- Rosenberg, D
- Sahar, D
- Martínez-Laperche, C
- Buño, I
- Hindley, A
- Donaldson, D
- Sánchez, JB
- García-Marco, JA
- Serrano-Alcalá, A
- Ferrer-Lores, B
- Fernández-Rodriguez, C
- Bellosillo, B
- Stilgenbauer, S
- Tausch, E
- Nikdin, H
- Quinn, F
- Atkinson, E
- van de Corput, L
- Yildiz, C
- Bilbao-Sieyro, C
- Florido, Y
- Thiede, C
- Schuster, C
- Stoj, A
- Czekalska, S
- Chatzidimitriou, A
- Laidou, S
- Bidet, A
- Dussiau, C
- Nollet, F
- Piras, G
- Monne, M
- Smirnova, S
- Nikitin, E
- Sloma, I
- Claudel, A
- Largeaud, L
- Ysebaert, L
- Valk, PJM
- Christian, A
- Walewska, R
- Oscier, D
- Sebastiao, M
- da Silva, MG
- Galieni, P
- Angelini, M
- Rossi, D
- Spina, V
- Matos, S
- Martins, V
- Stoklosa, T
- Pepek, M
- Baliakas, P
- Kahre, T
- Murumets, Ü
- Pikousova, T
- Kurucova, T
- Laird, S
- Ward, D
- Alcoceba, M
- Balanzategui, A
- Scarfo, L
- Gandini, F
- Zapparoli, E
- Blanco, A
- Abrisqueta, P
- Rodríguez-Vicente, AE
- Benito, R
- Bravetti, C
- Davi, F
- Gameiro, P
- Martinez-Lopez, J
- Tazón-Vega, B
- Baran-Marszak, F
- Davis, Z
- Catherwood, M
- Sudarikov, A
- Rosenquist, R
- Niemann, CU
- Stamatopoulos, K
- Ghia, P
- Pospisilova, S
Grupos
Abstract
In chronic lymphocytic leukemia, the reliability of next-generation sequencing (NGS) to detect TP53 variants <= 10% allelic frequency (low-VAF) is debated. We tested the ability to detect 23 such variants in 41 different laboratories using their NGS method of choice. The sensitivity was 85.6%, 94.5%, and 94.8% at 1%, 2%, and 3% VAF cut-off, respectively. While only one false positive (FP) result was reported at >2% VAF, it was more challenging to distinguish true variants <2% VAF from background noise (37 FPs reported by 9 laboratories). The impact of low-VAF variants on time-to-second-treatment (TTST) and overall survival (OS) was investigated in a series of 1092 patients. Among patients not treated with targeted agents, patients with low-VAF TP53 variants had shorter TTST and OS versus wt-TP53 patients, and the relative risk of second-line treatment or death increased continuously with increasing VAF. Targeted therapy in >= 2 line diminished the difference in OS between patients with low-VAF TP53 variants and wt-TP53 patients, while patients with high-VAF TP53 variants had inferior OS compared to wild type-TP53 cases. Altogether, NGS-based approaches are technically capable of detecting low-VAF variants. No strict threshold can be suggested from a technical standpoint, laboratories reporting TP53 mutations should participate in a standardized validation set-up. Finally, whereas low-VAF variants affected outcomes in patients receiving chemoimmunotherapy, their impact on those treated with novel therapies remains undetermined. Our results pave the way for the harmonized and accurate TP53 assessment, which is indispensable for elucidating the role of TP53 mutations in targeted treatment.
© 2025 The Author(s). HemaSphere published by John Wiley & Sons Ltd on behalf of European Hematology Association.
Datos de la publicación
- ISSN/ISSNe:
- 2572-9241, 2572-9241
- Tipo:
- Article
- Páginas:
- -
- DOI:
- 10.1002/hem3.70065
- PubMed:
- 39840379
- Enlace a otro recurso:
- www.scopus.com
- Factor de Impacto:
- 1,108 SCImago ℠
- Cuartil:
- Q1 SCImago ℠
HemaSphere WILEY
Citas Recibidas en Web of Science: 6
Documentos
Filiaciones
Keywords
- antileukemic agent; bcl2 inhibitor; bcr inhibitor; bendamustine; complementary DNA; cyclophosphamide; fludarabine; nucleotide; ofatumumab; protein p53; protein variant; rituximab; unclassified drug; adult; aged; amplicon; Article; background noise; cancer combination chemotherapy; cancer diagnosis; cancer survival; chronic lymphatic leukemia; clinical outcome; cohort analysis; controlled study; date of death; diagnostic accuracy; diagnostic test accuracy study; diagnostic value; droplet digital polymerase chain reaction; false positive result; female; first-line treatment; gene disruption; gene frequency; genetic variability; high throughput sequencing; human; illumina sequencing; limit of detection; major clinical study; male; molecular diagnosis; molecularly targeted therapy; overall survival; reproducibility; retrospective study; second-line treatment; sensitivity and specificity; time to second treatment
Cita
Pavlova S,Malcikova J,Radova L,Bonfiglio S,Cowland JB,Brieghel C,Andersen MK,Karypidou M,Biderman B,Doubek M,Lazarian G,Rapado I,Vynck M,Porret NA,Andres M,Rosenberg D,Sahar D,Martínez C,Buño I,Hindley A,Donaldson D,Sánchez JB,García JA,Serrano A,Ferrer B,Fernández C,Bellosillo B,Stilgenbauer S,Tausch E,Nikdin H,Quinn F,Atkinson E,van de Corput L,Yildiz C,Bilbao C,Florido Y,Thiede C,Schuster C,Stoj A,Czekalska S,Chatzidimitriou A,Laidou S,Bidet A,Dussiau C,Nollet F,Piras G,Monne M,Smirnova S,Nikitin E,Sloma I,Claudel A,Largeaud L,Ysebaert L,Valk PJM,Christian A,Walewska R,Oscier D,Sebastiao M,da MG,Galieni P,Angelini M,Rossi D,Spina V,Matos S,Martins V,Stoklosa T,Pepek M,Baliakas P,ANDREU R,LUNA I,Kahre T,Murumets Ü,Pikousova T,Kurucova T,Laird S,Ward D,Alcoceba M,Balanzategui A,Scarfo L,Gandini F,Zapparoli E,Blanco A,Abrisqueta P,Rodríguez AE,Benito R,Bravetti C,Davi F,Gameiro P,Martinez J,Tazón B,Baran F,Davis Z,Catherwood M,Sudarikov A,Rosenquist R,Niemann CU,Stamatopoulos K,Ghia P,Pospisilova S. Detection of clinically relevant variants in the TP53 gene below 10% allelic frequency: A multicenter study by ERIC, the European Research Initiative on CLL. Hemasphere. 2025. 9. (1):e70065. IF:11,400. (1).
Portal de investigación