Image reject analysis and rejection causes in digital radiography at a university hospital through estimates of patient doses.
Autores de IIS La Fe
Grupos
Abstract
The introduction of digital radiography has improved image acquisition. However, rejection of images remains a matter of concern. Reject analysis is part of the quality assurance program in radiology and helps identify potential errors or lack of training. A retrospective study was conducted at the radiology department of a university hospital. The reject rate was calculated both using the number of examinations, $r_n$, and the dose-area product, $r_d$. A reject rate $r_n$ of 3.3% for paediatric units and 4.5% for adults was found. The corresponding values of rd were 4.4 and 8.4%, respectively. The main rejection cause was patient motion, being 50.2% of rejected examinations in adults and 63.7% in children. The contribution of exposure errors was minor, as expected in digital radiography units. A discrepancy between reject rates $r_n$ and $r_d$ was observed, suggesting dosimetric quantities could be considered in reject analysis for further assessment of patient radiation burden.
© The Author(s) 2023. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Datos de la publicación
- ISSN/ISSNe:
- 0144-8420, 1742-3406
- Tipo:
- Article
- Páginas:
- 274-284
- DOI:
- 10.1093/rpd/ncad301
- Factor de Impacto:
- 0,355 SCImago ℠
- Cuartil:
- Q3 SCImago ℠
RADIATION PROTECTION DOSIMETRY OXFORD UNIV PRESS
Documentos
- No hay documentos
Filiaciones
Keywords
- RATES; FILM
Proyectos asociados
REALIZING THE EUROPEAN NETWORK IN BIODOSIMETRY (RENEB)
295513_RENEB_PE_MONTORO_FP7-Fission-2011 . FUNDACIÓN PARA LA INVESTIGACIÓN DEL HOSPITAL UNIVERSITARIO LA FE DE LA COMUNIDAD VALENCIANA . 2012
CONTROL Y SEGUIMIENTO INTEGRAL DE LA RADIACIÓN IONIZANTE RECIBIDA TRAS EXPLORACIONES MÉDICAS: COSIRI.
Investigador Principal: ÁNGEL ALBERICH BAYARRI
GV/2015/132 . FUNDACIÓN PARA LA INVESTIGACIÓN DEL HOSPITAL UNIVERSITARIO LA FE DE LA COMUNIDAD VALENCIANA; CONSELLERIA DE EDUCACION . 2015
Papel de la biodosimetría en la optimización del uso de 131I-MIBG como intensificación del tratamiento del neuroblastoma de alto riesgo.
Investigador Principal: JULIA BALAGUER GUILL
JBG-IOD-2017-01 . 2024
Estudio comparativo de ablación de tumores hepáticos empleando sistema de navegación IMACTIS mediante TIC y CBCT.
Investigador Principal: MAXIMILIANO LLORET LARREA
IMA-CT-CBCT . 2023
Cita
Calatayud J,Campayo JM,Gras P,Villaescusa JI. Image reject analysis and rejection causes in digital radiography at a university hospital through estimates of patient doses. Radiat Prot Dosimetry. 2023. 200. (3):p. 274-284. IF:0,800. (4).