Short versus long intramedullary nails for intertrochanteric hip fracture: Meta-analysis.
Autores de IIS La Fe
Participantes ajenos a IIS La Fe
- Domenech P
- Marquina V
Grupos
Abstract
OBJECTIVE: To compare short versus long intramedullary nails for intertrochanteric hip fractures in terms of efficacy and safety. METHODS: We included cohort studies and randomized clinical trials. The methodological quality of the studies was assessed by the Newcastle-Ottawa Scale. The meta-analysis was performed using the Review Manager 5.4. Heterogeneity was checked with the I(2) test. A fixed effects model was adopted if there was no heterogeneity. RESULTS: Twelve studies were included. The reoperations rate was lower in the short nail group (OR 0.58, 95% CI 0.38-0.88) and there were no differences regarding the peri-implant fracture rate (OR 1.77, 95% CI 0.68-4.60). Surgery time and blood loss was significantly higher in the long nail group (MD -12.44, 95% CI -14.60 to (-10.28)) (MD -19.36, 95% CI -27.24 to (-11.48)). There were no differences in functional outcomes. CONCLUSIONS: The long nail showed a higher reoperation rate, blood loss and surgery time compared to the short nail.
Copyright © 2023 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.
Datos de la publicación
- ISSN/ISSNe:
- 1888-4415, 1988-8856
- Tipo:
- Article
- Páginas:
- 373-382
- Factor de Impacto:
- 0,200 SCImago ℠
- Cuartil:
- Q3 SCImago ℠
Revista espanola de cirugia ortopedica y traumatologia Elsevier Doyma
Documentos
- No hay documentos
Filiaciones
Keywords
- Clavo corto; Clavo intramedular; Clavo largo; Fractura de cadera; Fractura intertrocantérica; Hip fracture; Intertrochanteric fracture; Intramedullary nail; Long nail; Meta-analysis; Metaanálisis; Short nail
Proyectos asociados
ESTUDIO EN FASE IIIB MULTICÉNTRICO, ALEATORIZADO, DOBLE CIEGO Y CONTROLADO, PARA EVALUAR LA EFICACIA Y SEGURIDAD DE RIVAROXABAN 10 MG FRENTE A ENOXAPARINA 4.000 UI PARA LA PROFILAXIS DE TEV EN CIRUGÍA ORTOPÉDICA MENOR. ESTUDIO PRONOMOS.
Investigador Principal: FRANCISCO BAIXAULI GARCÍA
1408143 . 2017
ESTUDIO ALEATORIZADO, DOBLE CIEGO, DOBLE SIMULACIÓN, MULTICÉNTRICO, DE DISEÑO ADAPTATIVO DE ESCALADA DE DOSIS (PARTE 1) Y DOSIS-RESPUESTA (PARTE 2) PARA EVALUAR LA SEGURIDAD Y LA EFICACIA DE JNJ-64179375 FRENTE A APIXABAN ORAL EN SUJETOS SOMETIDOS A UN REEMPLAZO TOTAL DE RODILLA.
Investigador Principal: FRANCISCO BAIXAULI GARCÍA
64179375THR2001 . 2017
ESTUDIO ALEATORIZADO PARA EVALUAR LA SEGURIDAD Y LA EFICACIA DE JNJ-70033093 (BMS-986177) POR VÍA ORAL FRENTE A ENOXAPARINA EN SUJETOS SOMETIDOS A UNA INTERVENCIÓN QUIRÚRGICA PROGRAMADA DE REEMPLAZO TOTAL DE RODILLA.
Investigador Principal: FRANCISCO BAIXAULI GARCÍA
70033093THR2001 . 2020
ESTUDIO FASE II/III, ALEATORIZADO, CONTROLADO, SIMPLE CIEGO PARA EVALUAR LA EFICACIA HEMOSTÁTICA Y LA SEGURIDAD DE TT-173 EN APLICACIÓN TÓPICA A PACIENTES SOMETIDOS A ARTROPLASTIA DE RODILLA.
Investigador Principal: MANUEL ANGULO SÁNCHEZ
THO-IM_02-CT . 2016
ESTUDIO EN FASE 2 ALEATORIZADO, CONTROLADO, ABIERTO (CIEGO PARA LA DOSIS), MULTICENTRICO, DE BUSQUEDA DE DOSIS DE SEGURIDAD Y EFICACIA DE I-0401 EN EL TRATAMIENTO DE PACIENTES CON FRACTURA DE MESETA TIBIAL QUE REQUIERAN INJERTO.
Investigador Principal: FRANCISCO BAIXAULI GARCÍA
CS-I-040101/02
ESTUDIO MULTICENTRICO, ALEATORIZADO, DOBLE-CIEGO, CONTROLADO CON PLACEBO DE GRUPOS PARALELOS PARA INVESTIGAR LA EFICACIA Y SEGURIDAD DE NORDITROPIN SIMPLEXX EN FRACTURAS DE TIBIA.
Investigador Principal: Francisco Baixauli Castella
NN1606-1365
Estudio de liberación de antibiótico y su capacidad microbiocida a partir de estructuras porosas impresas en tres dimensiones (3D) rellenas con sulfato cálcico impregnado con antibióticos.
Investigador Principal: LUCIA CUCÓ SANZ
2022-263-1_CRC_SECOT_CUCO . FUNDACION SECOT . 2022
Cita
Domenech P,Mariscal G,Marquina V,Baixauli F. Short versus long intramedullary nails for intertrochanteric hip fracture: Meta-analysis. Rev Esp Cir Ortop Traumatol. 2023. 68. (4):p. 373-382.