Durable ventricular assist device in Spain (2007-2020). First report of the REGALAD registry.
Fecha de publicación:
Fecha Ahead of Print:
Autores de IIS La Fe
Participantes ajenos a IIS La Fe
- Gomez-Bueno, Manuel
- Pérez de la Sota E
- Forteza Gil A
- Ortiz-Berbel, Daniel
- Castrodeza, Javier
- Garcia-Cosio, Maria Dolores
- Barge-Caballero, Eduardo
- Rangel Sousa D
- Díaz Molina B
- Manrique Antón R
- Uribarri González A
- Barrio-Rodriguez, Alfredo
- Castel Lavilla MÁ
- Lopez-Lopez, Laura
- Dobarro Pérez D
- Pastor Pérez F
- Burgos-Palacios, Virginia
- Alvarez-Garcia, Jesus
- Garrido-Jimenez, Jose Manuel
- Gonzalez-Fernandez, Oscar
- Codina, Pau
- Lopez-Granados, Amador
- Grau-Sepulveda, Andres
- Gonzalez-Costello, Jose
Grupos
Abstract
INTRODUCTION AND OBJECTIVES: This report presents the clinical characteristics, outcomes and complications of all consecutive patients implanted with a long-term mechanical circulatory support device in Spain between 2007 and 2020. METHODS: Analysis of the Spanish Registry of durable ventricular assist devices (REGALAD) including data form Spanish centers with a mechanical circulatory support program. RESULTS: During the study period, 263 ventricular assist devices were implanted in 22 hospitals. The implanted device was an isolated continuous-flow left ventricular assist device in 182 patients (69%), a pulsatile-flow device (58 isolated left ventricular and 21 biventricular) in 79 (30%), and a total artificial heart in 2 patients (1%). The strategy of the implant was as bridge to heart transplant in 78 patients (30%), bridge to candidacy in 110 (42%), bridge to recovery in 3 (1%) and destination therapy in 72 patients (27%). Overall survival at 6, 12 and 24 months was 79%, 74% and 69%, respectively, and was better in continuous-flow left ventricular assist devices (84%, 80%, and 75%). The main adverse events related to this therapy were infections (37% of patients), bleeding (35%), neurological (29%), and device malfunction (17%). CONCLUSIONS: Durable ventricular assist devices have emerged in Spain in the last few years as a useful therapy for patients with advanced heart failure. As in other international registries, the current trend is to use continuous-flow intracorporeal left ventricular devices, which are associated with better results. Adverse events continue to be frequent and severe.
Copyright © 2022. Published by Elsevier España, S.L.U.
Datos de la publicación
- ISSN/ISSNe:
- 1885-5857, 1885-5857
- Tipo:
- Article
- Páginas:
- 227-237
- PubMed:
- 36055642
- Factor de Impacto:
- 0,385 SCImago ℠
- Cuartil:
- Q3 SCImago ℠
REVISTA ESPANOLA DE CARDIOLOGIA EDICIONES DOYMA S A
Citas Recibidas en Web of Science: 9
Documentos
- No hay documentos
Filiaciones
Keywords
- Asistencia ventricular; Heart failure; Heart transplant; Insuficiencia cardiaca; Registro; Registry; Trasplante cardiaco; Ventricular assist device