INTRODUCTION AND OBJECTIVES: This report presents the clinical characteristics, outcomes and complications of all consecutive patients implanted with a long-term mechanical circulatory support device in Spain between 2007 and 2020. METHODS: Analysis of the Spanish Registry of durable ventricular assist devices (REGALAD) including data form Spanish centers with a mechanical circulatory support program. RESULTS: During the study period, 263 ventricular assist devices were implanted in 22 hospitals. The implanted device was an isolated continuous-flow left ventricular assist device in 182 patients (69%), a pulsatile-flow device (58 isolated left ventricular and 21 biventricular) in 79 (30%), and a total artificial heart in 2 patients (1%). The strategy of the implant was as bridge to heart transplant in 78 patients (30%), bridge to candidacy in 110 (42%), bridge to recovery in 3 (1%) and destination therapy in 72 patients (27%). Overall survival at 6, 12 and 24 months was 79%, 74% and 69%, respectively, and was better in continuous-flow left ventricular assist devices (84%, 80%, and 75%). The main adverse events related to this therapy were infections (37% of patients), bleeding (35%), neurological (29%), and device malfunction (17%). CONCLUSIONS: Durable ventricular assist devices have emerged in Spain in the last few years as a useful therapy for patients with advanced heart failure. As in other international registries, the current trend is to use continuous-flow intracorporeal left ventricular devices, which are associated with better results. Adverse events continue to be frequent and severe.

Copyright © 2022. Published by Elsevier España, S.L.U.

Datos de la publicación

ISSN/ISSNe:
1885-5857, 1885-5857

REVISTA ESPANOLA DE CARDIOLOGIA  EDICIONES DOYMA S A

Tipo:
Article
Páginas:
227-237
PubMed:
36055642
Factor de Impacto:
0,385 SCImago ℠
Cuartil:
Q3 SCImago ℠

Citas Recibidas en Web of Science: 9

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Asistencia ventricular; Heart failure; Heart transplant; Insuficiencia cardiaca; Registro; Registry; Trasplante cardiaco; Ventricular assist device

Cita

Compartir