Classification Predictive Model for Air Leak Detection in Endoworm Enteroscopy System.

Autores de IIS La Fe
Participantes ajenos a IIS La Fe
- Zazo-Manzaneque, Roberto
- Vidaurre, Ana
- Santonja, Alberto
- Sanchez-Diaz, Carlos
Grupos
Abstract
Current enteroscopy techniques present complications that are intended to be improved with the development of a new semi-automatic device called Endoworm. It consists of two different types of inflatable cavities. For its correct operation, it is essential to detect in real time if the inflatable cavities are malfunctioning (presence of air leakage). Two classification predictive models were obtained, one for each cavity typology, which must discern between the ``Right'' or ``Leak'' states. The cavity pressure signals were digitally processed, from which a set of features were extracted and selected. The predictive models were obtained from the features, and a prior classification of the signals between the two possible states was used as input to different supervised machine learning algorithms. The accuracy obtained from the classification predictive model for cavities of the balloon-type was 99.62%, while that of the bellows-type was 100%, representing an encouraging result. Once the models are validated with data generated in animal model tests and subsequently in exploratory clinical tests, their incorporation in the software device will ensure patient safety during small bowel exploration.
Datos de la publicación
- ISSN/ISSNe:
- 1424-8220, 1424-8220
- Tipo:
- Article
- Páginas:
- -
- DOI:
- 10.3390/s22145211
- Factor de Impacto:
- 0,803 SCImago ℠
- Cuartil:
- Q1 SCImago ℠
SENSORS MDPI AG
Documentos
- No hay documentos
Filiaciones
Keywords
- classification predictive models; digital signal processing; enteroscopy; feature extraction; inflatable cavities; medical device; real-time detection system; soft robot
Proyectos asociados
RED DE INNOVACION EN TECNOLOGIAS MEDICAS Y SANITARIAS - RED ITEMAS
Investigador Principal: JOSÉ VICENTE CASTELL RIPOLL
RD09/0077/00156 . INSTITUTO DE SALUD CARLOS III . 2010
WIBEC. WIRELESS IN-BODY ENVIRONMENT COMMUNICATIONS.
Investigador Principal: VICENTE PONS BELTRÁN
675353 . COMISION EUROPEA . 2016
Optimización del dispositivo Endoworm de asistencia para la realización de enteroscopia.
Investigador Principal: VICENTE PONS BELTRÁN
PI18/01365 . INSTITUTO DE SALUD CARLOS III . 2019
ESTUDIO DE FASE III, ALEATORIZADO, A DOBLE CIEGO, CONTROLADO CON PLACEBO SOBRE TERAPIA ADYUVANTE CON VEMURAFENIB (RO5185426) EN PACIENTES CON MELANOMA CUTÁNEO CON MUTACIÓN DE BRAF RESECADO QUIRÚRGICAMENTE CON ALTO RIESGO DE RECIDIVA.
Investigador Principal: ROBERTO PEDRO DÍAZ BEVERIDGE
GO27826 . 2013
ESTUDIO ALEATORIZADO Y ABIERTO, PARA COMPARAR DURANTE 26 SEMANAS EL EFECTO DEL TRATAMIENTO CON GEL INTESTINAL DE LEVODOPA-CARBIDOPA (GILC) Y DEL TRATAMIENTO MÉDICO ÓPTIMO (TMO) SOBRE LOS SÍNTOMAS NO MOTORES (SNM) EN PACIENTES CON ENFERMEDAD DE PARKINSON AVANZADA - ESTUDIO INSIGHTS.
Investigador Principal: IRENE MARTÍNEZ TORRES
M12-927 . 2015
A RANDOMIZED, DOUBLE-BLIND, PLACEBO-CONTROLLED PHASE 4 STUDY TO EVALUATE THE EFFICACY AND SAFETY OF ENTYVIO (VEDOLIZUMAB IV) IN THE TREATMENT OF CHRONIC POUCHITIS./ ESTUDIO DE FASE IV ALEATORIZADO, DOBLE CIEGO Y CONTROLADO CON PLACEBO PARA EVALUAR LA EFICACIA Y LA SEGURIDAD DE ENTYVIO (VEDOLIZUMAB I.V.) EN EL TRATAMIENTO DE LA POUCHITIS CRÓNICA.
Investigador Principal: GUILLERMO BASTIDA PAZ
VEDOLIZUMAB-4004 . 2017
ESTUDIO DE INDUCCIÓN MULTICÉNTRICO, ALEATORIZADO, DOBLE CIEGO, CONTROLADO CON PLACEBO PARA EVALUAR LA EFICACIA Y SEGURIDAD DE UPADACITINIB (ABT 494) EN PACIENTES CON COLITIS ULCEROSA DE MODERADA A GRAVE.
Investigador Principal: MARISA IBORRA COLOMINO
M14-675 . 2019
ESTUDIO OBSERVACIONAL PARA LA EVALUACIÓN DE DIFERENTES PREPARACIONES PARA LA REALIZACIÓN DE CÁPSULA ENDOSCÓPICA MEDIANTE UN SISTEMA DE DETECCIÓN AUTOMÁTICA.
Investigador Principal: VICENTE PONS BELTRÁN
VPB-MAC-2019-01 . 2020
ESTUDIO EN FASE III, CIEGO, ALEATORIZADO, MULTICENTRICO, PARA LA EVALUACION DE SEGURIDAD Y EFICACIA DE CITRAFLEET (R) (PICOSULFATO SODICO) COMO TRATAMIENTO EVACUANTE PREVIO A EXPLORACION ENDOSCOPICA COLONICA.
Investigador Principal: VICENTE PONS BELTRÁN
CF-PICOS2006
Diseño y evaluación funcional de un nuevo dispositivo médico de catéter con balón para el tratamiento endoscópico de las fístulas del tracto digestivo. EndoFis.
Investigador Principal: MARÍA GARCÍA CAMPOS
2021/VSC/PEA/0195 . FUNDACION DE LA SOCIEDAD ESPAÑOLA DE ENDOSCOPIA DIGESTIVA . 2021
Cita
Zazo R,Pons V,Vidaurre A,Santonja A,Sanchez C. Classification Predictive Model for Air Leak Detection in Endoworm Enteroscopy System. Sensors (Basel). 2022. 22. (14):5211. IF:3,900. (2).