Spanish Pacemaker Registry. Eleventh official report of the Spanish Society of Cardiology Working Group on Cardiac Pacing (2013).
Autores de IIS La Fe
Participantes ajenos a IIS La Fe
- Coma Samartín R
- Pombo Jiménez M
Grupos
Abstract
INTRODUCTION AND OBJECTIVES: The present report summarizes the analysis of pacemaker implantation and replacement data sent to the Spanish Pacemaker Registry in 2013, with specific discussion of pacing mode selection. METHODS: This study was based on information obtained from the European Pacemaker Patient Identification Card. RESULTS: Information was received on 118 hospital centers, with a total of 12 831 cards, or 35% of the estimated activity. There were 755 and 58.1 conventional and resynchronization devices per million population, respectively. The mean age of patients receiving an implant was 77.4 years. Men received 59.5% of first implantations and 56.6% of replacements. Most implantations and generator replacements were performed in patients older than 80 years. Almost all endocardial leads used were bipolar, and 78.7% of leads had an active fixation mechanism. Despite being in sinus rhythm, 24% of patients with sick sinus syndrome and 25% of those with atrioventricular block were paced in VVIR mode. CONCLUSIONS: The use of pacemaker generators and resynchronization devices per million population continues to increase in Spain. Active fixation mechanisms predominate for leads but just 20% of leads are compatible with magnetic resonance imaging. The factors influencing the correct selection of pacing mode were age and, to a lesser extent, the type of atrioventricular block, and sex. Implementation of home monitoring of pacemakers remains low.
Datos de la publicación
- ISSN/ISSNe:
- 1885-5857, 1885-5857
- Tipo:
- Article
- Páginas:
- 1024-1038
- PubMed:
- 25455755
- Factor de Impacto:
- 0,104 SCImago ℠
- Cuartil:
- Q4 SCImago ℠
REVISTA ESPANOLA DE CARDIOLOGIA Elsevier Doyma
Citas Recibidas en Web of Science: 11
Documentos
- No hay documentos
Filiaciones
Keywords
- Biventricular pacing; Cables marcapasos; Estimulacion biventricular; Marcapasos; Pacemaker leads; Pacemakers; Registro; Registry
Proyectos y Estudios Clínicos
MORE-CRT: EL AUMENTO DE LAS OPCIONES DISPONIBLES CON UN ELECTRODO VI TETRAPOLAR OFRECE SOLUCIONES CLÍNICAS A LOS PROBLEMAS DE LA TRC. MORE OPTIONS AVAILABLE WITH A QUADRIPOLAR LV LEAD PROVIDE IN CLINIC SOLUTIONS TO CRT CHALLENGES.
Investigador Principal: JOAQUÍN OSCA ASENSI
CR-11-006-HF-ID . 2012
GLORIA - AF: REGISTRO GLOBAL DEL TRATAMIENTO ANTITROMBÓTICO ORAL A LARGO PLAZO EN PACIENTES CON FIBRILACIÓN AURICULAR (FASE II/III – ESTADOS MIEMBROS DE LA UE/ AEE).
Investigador Principal: JOAQUÍN OSCA ASENSI
BOE-DAB-2012-01 . 2013
MORE RESPONSE ON CARDIAC RESYNCHRONIZATION THERAPY (CRT) WITH MULTIPOINT PACING (MPP) – MAYOR RESPUESTA A LA TERAPIA DE RESINCRONIZACIÓN CARDIACA (TRC) CON ESTIMULACIÓN MULTISITIO.
Investigador Principal: JOAQUÍN OSCA ASENSI
CR-13-006-ID-HF . 2013
ESTIMULACIÓN TRICAMERAL EN PACIENTES CON CARDIOMIOPATÍA HIPERTRÓFICA OBSTRUCTIVA. TRICHAMPION (TRIPLE CHAMBER PACING IN HOCM PATIENTS).
Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA
CR-11-030-EU-HF . 2014
INVESTIGACIÓN CLÍNICA SOBRE LAS DIFERENCIAS EN LA MAGNITUD DE LA RESPUESTA A LA TRC ENTRE HOMBRES Y MUJERES. (BIOWOMEN).
Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA
CR017 . 2015
ESTUDIO OASIS-H. ORGANIZACION ASISTENCIAL DE PACIENTES CON HOME MONITORING.
Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA
OASIS-HM . 2010
ENSAYO CLÍNICO DEL ELECTRODO SONRTIP Y EL ALGORITMO DE OPTIMIZACIÓN AV-VV EN EL PARADYM RF SONR CRT-D.
Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA
ITSY06 . 2012
EVALUACIÓN DE UN PROGRAMA EDUCACIÓN Y GUÍA PARA LA ADHERENCIA A ELIQUIS EN FIBRILACIÓN AURICULAR NO VALVULAR (AEGEAN).
Investigador Principal: MARÍA VILAR PALOP
CV185220 . 2014
MONITORING RESYNCHRONIZATION IN CARDIAC PATIENTS.
Investigador Principal: JOSE OLAGUE DE ROS
MORE-CARESTUDY . 2009
ESTUDIO DE LA EFICACIA Y LA SEGURIDAD DE F373280 EN EL MANTENIMIENTO DEL RITMO SINUSAL TRAS CARDIOVERSIÓN ELÉCTRICA EN PACIENTES CON FIBRILACIÓN AURICULAR PERSISTENTE E INSUFICIENCIA CARDÍACA CRÓNICA. INTERNACIONAL, MULTICÉNTRICO, ALEATORIZADO, DOBLE CIEG O Y CONTROLADO CON PLACEBO.
Investigador Principal: JOAQUÍN OSCA ASENSI
F373280CA201
ESTUDIO OBSERVACIONAL PARA LA EVALUACIÓN DEL MANEJO DE PACIENTES RESINCRONIZADOS CON EL ELECTRODO TETRAPOLAR QUARTETTM DE VENTRÍCULO IZQUIERDO.
Investigador Principal: JOSE OLAGUE DE ROS
CR-12-015-SP-HF
REDUCCIÓN DE CHOQUES INAPROPIADOS CON EL DISCRIMINADOR DE RITMO PARAD+.
Investigador Principal: JOSE OLAGUE DE ROS
ITSY09