Use of the Ultrasound Technique as Compared to the Standard Technique for the Improvement of Venous Cannulation in Patients with Difficult Access.

Autores de IIS La Fe
Participantes ajenos a IIS La Fe
- Rodríguez-Herrera Á
- Mollá-Olmos E
- Ferrer-Puchol D
- Esteve-Claramunt F
- Trujillo-Barberá S
- García-Bermejo P
- Casaña-Mohedo J
Grupos
Abstract
(1) Objective. We aimed to demonstrate that the use of the ultrasound-guided technique facilitates peripheral venous cannulation as compared to the standard technique in patients with difficult access at emergency services. (2) Method. A case-control study, randomized research. Variables were collected from a population with non-palpable or not visible veins, classified into size risk groups for 6 months. In the comparative analysis, the patients were divided into two groups: the cases group was composed of patients to whom the peripheral venous cannulation was performed with the ultrasound-guided technique (UST), while the control was composed of patients with whom the standard technique (ST) was performed. The ultrasound LOGIQ P5 750VA from General Electric Healthcare, with an 11 mHz linear probe, was utilized, along with peripheral venous catheters model Insyte TM Autoguard TM with gauges of 14G to 26G. (3) Results. Seventy-two cases. The use of the ultrasound decreased the time (618.34s ST, 126s UST) and the number of punctures (2.92 ST, 1.23 UST); about 25% of the patients did not have complications with the UST, as compared to 8% with the ST. The use of the ultrasound decreased the pain experienced by 1.44 points in the visual analog scale, as compared to 0.11 points with the ST. The rate of success of the first try with the UST was 76%, as compared to 16% of the ST. The gauge of the catheter increased with the UST, with successful cannulations obtained with 20G (56%) and 18G (41%) gauges. (4) Conclusions. The use of ultrasound facilitates venous cannulation according to the variables of the study. The ultrasound visualization of the vessels is associated with the selection of the catheter gauge. There was no relation between the complications and the depth of the blood vessels.
Datos de la publicación
- ISSN/ISSNe:
- 2227-9032, 2227-9032
- Tipo:
- Article
- Páginas:
- -
- PubMed:
- 35206876
- Factor de Impacto:
- 0,529 SCImago ℠
- Cuartil:
- Q2 SCImago ℠
HEALTHCARE MDPI
Citas Recibidas en Web of Science: 2
Documentos
- No hay documentos
Filiaciones
Keywords
- emergencies, nursing peripheral cannulation, ultrasound
Proyectos y Estudios Clínicos
EFECTO DEL ALOPURINOL EN PACIENTES CON ENCEFALOPATÍA HIPÓXICO-ISQUÉMICA TRATADOS CON HIPOTERMIA – ALBINO – ENSAYO CLÍNICO MULTICÉNTRICO, ALEATORIZADO, CIEGO, CONTROLADO CON PLACEBO.
Investigador Principal: MÁXIMO VENTO TORRES
ALBINO . 2018
ENSAYO CLÍNICO FASE I PARA ESTABLECER LA SEGURIDAD DEL USO DE CÉLULAS MESENQUIMALES TRONCALES FETALES ALOGÉNICAS DE CORDÓN UMBILICAL EXPANDIDAS EN PACIENTES PREMATUROS CON DISPLASIA BRONCOPULMONAR.
Investigador Principal: MÁXIMO VENTO TORRES
PULMESCEL-1 . 2019
Short- and long-term impact assessment of inhaled nitric oxide in the treatment of severe hypoxia secondary to persistent pulmonary hypertension in the newborn period (Impacto a corto y largo plazo de la terapia con óxido nítrico inhalado para el tratamiento de hipóxia severa secundaria a la hipertensión pulmonar persistente en el periodo neonatal).
Investigador Principal: JULIA KULIGOWSKI
PI20/00964 . INSTITUTO DE SALUD CARLOS III . 2021
Gut microbiota profiles involved in the onset of autism spectrum disorders in preterm infants: a two-year follow-up study.
Investigador Principal: ANA CRISTINA GARCÍA BLANCO
PI21/00549 . INSTITUTO DE SALUD CARLOS III . 2022
MANEJO INICIAL DE LA DILATACIÓN PIELOCALICIAL DE DIAGNÓSTICO PRENATAL.
Investigador Principal: MARIA PEREZ CHAMORRO
UNE-AMO-2019-01 . 2020
TARGETED OXYGENATION IN THE RESPIRATORY CARE OF PREMATURE INFANTS AT DELIVERY: EFFECTS ON OUTCOME (TORPIDO 30/60)./ OXIGENACIÓN DIRIGIDA EN LA ATENCIÓN RESPIRATORIA DE BEBÉS PREMATUROS EN EL PARTO: EFECTOS SOBRE EL RESULTADO (TORPIDO 30/60).
Investigador Principal: MÁXIMO VENTO TORRES
CTC022ACTRN12618000879268 . 2021
Eficacia y Seguridad de la Clorhexidina alcohólica al 2% en recién nacidos.
Investigador Principal: MARÍA CERNADA BADÍA
2021-816-1_EOm . 2021
Cita
Rodríguez Á,SOLAZ Á,Mollá E,Ferrer D,Esteve F,Trujillo S,García P,Casaña J. Use of the Ultrasound Technique as Compared to the Standard Technique for the Improvement of Venous Cannulation in Patients with Difficult Access. Healthcare. 2022. 10. (2):261. IF:2,800. (3).