Nanoporous Anodic Alumina-Based Sensor for miR-99a-5p Detection as an Effective Early Breast Cancer Diagnostic Tool.
Autores de IIS La Fe
Participantes ajenos a IIS La Fe
- Garrido-Cano I
- Simón S
- Ortega B
- Bermejo B
- Lluch A
- Cejalvo JM
- Eroles P
Grupos
Abstract
Circulating microRNAs have emerged as potential diagnostic biomarkers. The deregulation of the microRNA miR-99a-5p has been previously described as an effective biomarker of early breast cancer. Herein, we present a new nanoporous anodic alumina (NAA)-based biosensor that can detect plasma miR-99a-5p with high sensitivity and selectivity. NAA pores are loaded with rhodamine B and capped with a specific oligonucleotide that is able to block cargo release until the target is present. In the presence of miR-99a-5p, the capping oligonucleotide recognizes the miR-99a-5p sequence and displaces it allowing the release of the encapsulated dye. This method is able to successfully distinguish healthy controls from breast cancer patients, even at early stages with high efficiency, showing the presented system as a promising tool for breast cancer detection.
Datos de la publicación
- ISSN/ISSNe:
- 2379-3694, 2379-3694
- Tipo:
- Article
- Páginas:
- 1022-1029
- Factor de Impacto:
- 1,833 SCImago ℠
- Cuartil:
- Q1 SCImago ℠
ACS Sensors American Chemical Society
Citas Recibidas en Web of Science: 9
Documentos
- No hay documentos
Filiaciones
Keywords
- biosensor, breast cancer, diagnosis, nanoporous anodic alumina, plasma
Proyectos asociados
NANOMATERIALES INTELIGENTES, SONDAS Y DISPOSITIVOS PARA EL DESARROLLO INTEGRADO DE NUEVAS HERRAMIENTAS APLICADAS AL CAMPO BIOMÉDICO
Investigador Principal: JUAN BAUTISTA SALOM SANVALERO
MAT2015-64139-C4-1-R . MINISTERIO DE ECONOMIA Y COMPETITIVIDAD . 2016
PROGRAMA TÉCNICO DE APOYO. MODALIDAD INFRAESTRUCTURA.
Investigador Principal: RAMÓN MARTÍNEZ MÁÑEZ
PTA2016-12603-1 . MINISTERIO DE ECONOMIA Y COMPETITIVIDAD . 2018
Contrato I-PFIS: Predoctorales de formación en investigación en salud.
Investigador Principal: RAMÓN MARTÍNEZ MÁÑEZ
IFI17/00039 . INSTITUTO DE SALUD CARLOS III . 2018
Contrato Post FSE (Rio Hortega)
Investigador Principal: RAMÓN MARTÍNEZ MÁÑEZ
CM18/00078 . INSTITUTO DE SALUD CARLOS III . 2019
PLATAFORMA PARA LA DETECCIÓN DE PATÓGENOS BASADA EN MATERIALES CON PUERTAS MOLECULARES (PATH-GATE).
Investigador Principal: RAMÓN MARTÍNEZ MÁÑEZ
DTS18/00090 . INSTITUTO DE SALUD CARLOS III . 2019
DESARROLLO Y VALIDACIÓN DE SISTEMAS DIAGNÓSTICOS PARA EL CRIBADO Y LA DETECCIÓN RÁPIDA Y CONFIABLE DE PACIENTES CON INFECCIÓN DE COVID-19 (DIACOVID)
Investigador Principal: RAMÓN MARTÍNEZ MÁÑEZ
2020-528-1_CRC_DIACOVID_MARTINEZ . BANCO SANTANDER . 2021
Cita
Garrido I,Pla L,Santiago S,Simón S,Ortega B,Bermejo B,Lluch A,Cejalvo JM,Eroles P,Martínez R. Nanoporous Anodic Alumina-Based Sensor for miR-99a-5p Detection as an Effective Early Breast Cancer Diagnostic Tool. ACS Sens. 2021. 6. (3):p. 1022-1029. IF:9,618. (1).