Flash glucose monitoring reduces glycemic variability and hypoglycemia: real-world data from Spain

Fecha de publicación:

Autores de IIS La Fe

Participantes ajenos a IIS La Fe

  • Gomez-Peralta F
  • Dunn T
  • Landuyt K
  • Xu Y

Grupos

Abstract

Objective Observations in real-world settings support and extend findings demonstrated in randomized controlled trials that show flash glucose monitoring improves glycemic control. In this study, Spain-specific relationships between testing frequency and glycemic parameters were investigated under real-world settings. Research design and methods Deidentified glucose and user scanning data were analyzed and readers were rank ordered into 20 equal sized groups by daily scan frequency. Glucose parameters were calculated for each group: estimated HbA1c, time below range (<70 and <= 54 mg/dL), within range (70-180 mg/dL), and above range (>180 mg/dL). Glycemic variability (GV) metrics were described and data obtained from sensors in Spain and worldwide were compared. Results Spanish users (n=22 949) collected 37.1 million glucose scans, 250 million automatically recorded glucose readings, and checked glucose values via a mean of 13 scans/day. Estimated HbA1c, time below 70 mg/dL, at or below 54 mg/dL, above 180 mg/dL, and GV metrics were significantly lower in the highest compared with lowest scan rate group (39.6 to 3.9 scans/day). Time-in-range was higher for the highest versus lowest scan rate group at 15.6 vs 11.5 hours/day, respectively. GV metrics correlated positively with time below 70 mg/dL, at or below 54 mg/dL, above 180 mg/dL, and negatively with time-in-range. The relationship between glucose metrics and scan rate was similar in Spain and worldwide. However, time in hypoglycemia in Spain was higher in the groups with lower scan rates. Conclusions As seen in clinical trials, flash glucose monitoring in real-world settings allows frequent glucose checks. High scan rates are associated with the favorable glycemic markers of increased time-in-range and reduced time in hyperglycemia and hypoglycemia, and GV. The same trends, with unique nuances, are observed in both Spanish and global data.

Datos de la publicación

ISSN/ISSNe:
2052-4897, 2052-4897

BMJ Open Diabetes Research & Care  BMJ PUBLISHING GROUP

Tipo:
Article
Páginas:
-
PubMed:
32198165
Factor de Impacto:
1,347 SCImago
Cuartil:
Q1 SCImago

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • blood glucose monitoring; glycemic control; hypoglycemia

Cita

Compartir