Phantom development for daily checks in electron intraoperative radiotherapy with a mobile linac
Autors de IIS La Fe
Autors aliens a IIS La Fe
- Sanchis-Sanchez, E
- Collado, J
- Gonzalez, V
- Perez-Calatayud, I
- Perez-Calatayud, MJ
- Bonet-Sancho, JL
- Garcia-Sanchez, AJ
- Sanchis, E
Grups d'Investigació
Abstract
Purpose: IORT with mobile linear accelerators is a well-established modality where the dose rate and, therefore, the dose per pulse are very high. The constancy of the dosimetric parameters of the accelerator has to be checked daily. The aim of this work is to develop a phantom with embedded detectors to improve both accuracy and efficiency in the daily test of an IORT linac at the surgery room. Methods: The developed phantom is manufactured with transparent polymethyl methacrylate (PMMA), allocating 6 parallel-plate chambers: a central one to evaluate the on-axis beam output, another on-axis one placed at a fixed depth under the previous one to evaluate the energy constancy and four off-axis chambers to evaluate the flatness and symmetry. To analyse the readings a specific application has been developed. Results: For all chambers and energies, the mean saturation and polarization corrections were smaller than 0.7%. The beam is monitored at different levels of the clinical beam. Output, energy constancy and flatness correlate very well with the correspondent values with the complete applicator. During the first six months of clinical use the beam dosimetric parameters showed excellent stability. Conclusions: A phantom has been developed with embedded parallel plate chambers attached to the upper applicator part of an IORT linac. The phantom allows a very efficient setup reducing the time to check the parameters. It provides complete dosimetric information (output, energy and flatness) with just one shot and using ionization chambers with minimum saturation effect, as this highly pulsed beam requires.
Dades de la publicació
- ISSN/ISSNe:
- 1120-1797, 1724-191X
- Tipus:
- Article
- Pàgines:
- 109-116
- PubMed:
- 32673822
- Factor d'Impacte:
- 0,883 SCImago ℠
- Quartil:
- Q1 SCImago ℠
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS ELSEVIER SCI LTD
Documents
- No hi ha documents
Filiacions
Keywords
- Intraoperative radiotherapy; Electrons; Quality assurance; Dosimetry
Projectes associats
Papel de la biodosimetría en la optimización del uso de 131I-MIBG como intensificación del tratamiento del neuroblastoma de alto riesgo.
Investigador Principal: JULIA BALAGUER GUILL
JBG-IOD-2017-01 . 2024
ESTUDIO OBSERVACIONAL PARA DESCRIBIR RETROSPECTIVAMENTE LA EVOLUCIÓN DE LOS PACIENTES CON CÁNCER DE PRÓSTATA A LO LARGO DE LA ENFERMEDAD A TRAVÉS DE LA REUTILIZACIÓN DE LOS REGISTROS ELECTRÓNICOS DE SALUD CON INTELIGENCIA ARTIFICIAL. ESTUDIO OVERVIEW.
Investigador Principal: ANTONIO CONDE MORENO
JAN-CPR-2018-01 . 2018
ESTUDIO DE BRAQUITERAPIA ELECTRÓNICA PARA CARCINOMA CUTÁNEO BASOCELULAR.
Investigador Principal: JOSÉ PÉREZ CALATAYUD
BCCBRACHY