Improved in vivo efficacy of clinical-grade cryopreserved human hepatocytes in mice with acute liver failure.

Fecha de publicación: Fecha Ahead of Print:

Autores de IIS La Fe

  • Miguel Bolonio Garcia

    Autor

  • Estefania Cabezas Marcos

    Autor

  • María Pelechá Salvador

    Autor

  • Eugenia Pareja Ibars

    Autor

  • Antonio Doménech Carbó

    Autor

  • José Vicente Castell Ripoll

    Autor

  • María José Gómez-Lechón Moliner

    Autor

Grupos

Abstract

Clinical hepatocyte transplantation short-term efficacy has been demonstrated; however, some major limitations, mainly due to the shortage of organs, the lack of quality of isolated cells and the low cell engraftment after transplantation, should be solved for increasing its efficacy in clinical applications. Cellular stress during isolation causes an unpredictable loss of attachment ability of the cells, which can be aggravated by cryopreservation and thawing. In this work, we focused on the use of a Good Manufacturing Practice (GMP) solution compared with the standard cryopreservation medium, the University of Wisconsin medium, for the purpose of improving the functional quality of cells and their ability to engraft in vivo, with the idea of establishing a biobank of cryopreserved human hepatocytes available for their clinical use. We evaluated not only cell viability but also specific hepatic function indicators of the functional performance of the cells such as attachment efficiency, ureogenic capability, phase I and II enzymes activities and the expression of specific adhesion molecules in vitro. Additionally, we also assessed and compared the in vivo efficacy of human hepatocytes cryopreserved in different media in an animal model of acute liver failure. Human hepatocytes cryopreserved in the new GMP solution offered better in vitro and in vivo functionality compared with those cryopreserved in the standard medium. Overall, the results indicate that the new tested GMP solution maintains better hepatic functions and, most importantly, shows better results in vivo, which could imply an increase in long-term efficacy when used in patients.

Datos de la publicación

ISSN/ISSNe:
1465-3249, 1477-2566

CYTOTHERAPY  ELSEVIER SCI LTD

Tipo:
Article
Páginas:
114-121
PubMed:
31987755
Factor de Impacto:
1,192 SCImago ℠
Cuartil:
Q1 SCImago ℠

Citas Recibidas en Web of Science: 5

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • cryopreservation, engraftment, hepatocyte transplantation, metabolic performance

Cita

Compartir