Spanish Pacemaker Registry. 16th Official Report of the Spanish Society of Cardiology Working Group on Cardiac Pacing (2018)

Fecha de publicación:

Autores de IIS La Fe

Participantes ajenos a IIS La Fe

  • Jimenez, MP
  • Carreno, DL
  • Garcia, JC

Grupos

Abstract

Introduction and objectives: This report describes the result of the analysis of the implanted pacemakers reported to the Spanish Pacemaker Registry in 2018. Methods: The analysis is based on the information provided by the European Pacemaker Identification Card and supplier-reported data on the overall number of implanted pacemakers. Results: Information was received from 90 hospitals, with a total of 12 148 cards, representing 31% of the estimated activity. Use of conventional and resynchronization pacemakers was 825 and 77 units per million people, respectively. The mean age of the patients receiving an implant was 78.3 years, and 54% of the devices were implanted in people aged > 80 years. A total of 77.1% were first implants and 21.6% corresponded to generator exchanges. Bicameral sequential pacing was the most frequent pacing mode but was less frequently used in patients aged > 80 years and in women. Single chamber VVI/R pacing was used in 28% of patients with sick sinus syndrome and in 24.7% of those with atrioventricular block, despite being in sinus rhythm. Conclusions: The total consumption of pacemaker generators in Spain increased by 1.2% compared with 2017, mainly due to an 8.7% increase in cardiac resynchronization therapy with pacemaker generators. Selection of pacing mode was directly influenced by age and sex. (C) 2019 Sociedad Espanola de Cardiologia. Published by Elsevier Espana, S.L.U. All rights reserved.

Datos de la publicación

ISSN/ISSNe:
0300-8932, 1579-2242

REVISTA ESPANOLA DE CARDIOLOGIA  EDICIONES DOYMA S A

Tipo:
Article
Páginas:
944-953
Factor de Impacto:
0,473 SCImago
Cuartil:
Q3 SCImago

Citas Recibidas en Web of Science: 10

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Permanent cardiac pacing; Pacemaker leads; Biventricular pacing; Registry

Campos de estudio

Proyectos asociados

INCORPORACIÓN GRUPOS CIBER. DR. DOLZ

Investigador Principal: LUIS VICENTE MARTÍNEZ DOLZ

CB16/11/00261 . INSTITUTO DE SALUD CARLOS III . 2017

Validación prospectiva de un índice pronóstico de muerte súbita o arritmias ventriculares malignas en adultos con cardiopatías congénitas.

Investigador Principal: TOMAS DATINO ROMANIEGA

PI17/01327 . 2018

MORE-CRT: EL AUMENTO DE LAS OPCIONES DISPONIBLES CON UN ELECTRODO VI TETRAPOLAR OFRECE SOLUCIONES CLÍNICAS A LOS PROBLEMAS DE LA TRC. MORE OPTIONS AVAILABLE WITH A QUADRIPOLAR LV LEAD PROVIDE IN CLINIC SOLUTIONS TO CRT CHALLENGES.

Investigador Principal: JOAQUÍN OSCA ASENSI

CR-11-006-HF-ID . 2012

GLORIA - AF: REGISTRO GLOBAL DEL TRATAMIENTO ANTITROMBÓTICO ORAL A LARGO PLAZO EN PACIENTES CON FIBRILACIÓN AURICULAR (FASE II/III – ESTADOS MIEMBROS DE LA UE/ AEE).

Investigador Principal: JOAQUÍN OSCA ASENSI

BOE-DAB-2012-01 . 2013

MORE RESPONSE ON CARDIAC RESYNCHRONIZATION THERAPY (CRT) WITH MULTIPOINT PACING (MPP) – MAYOR RESPUESTA A LA TERAPIA DE RESINCRONIZACIÓN CARDIACA (TRC) CON ESTIMULACIÓN MULTISITIO.

Investigador Principal: JOAQUÍN OSCA ASENSI

CR-13-006-ID-HF . 2013

ESTIMULACIÓN TRICAMERAL EN PACIENTES CON CARDIOMIOPATÍA HIPERTRÓFICA OBSTRUCTIVA. TRICHAMPION (TRIPLE CHAMBER PACING IN HOCM PATIENTS).

Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA

CR-11-030-EU-HF . 2014

INVESTIGACIÓN CLÍNICA SOBRE LAS DIFERENCIAS EN LA MAGNITUD DE LA RESPUESTA A LA TRC ENTRE HOMBRES Y MUJERES. (BIOWOMEN).

Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA

CR017 . 2015

ESTIMULACIÓN BIVENTRICULAR TRIFOCAL PARA LA OPTIMIZACIÓN DE LA TERAPIA DE RESINCRONIZACIÓN CARDIACA (TRC).

Investigador Principal: ÓSCAR CANO PÉREZ

ICSY02 . 2015

EVALUACIÓN CLÍNICA DEL PACIENTE Y FUNCIONAL DEL DISPOSITIVO EN LA PRÁCTICA CLÍNICA HABITUAL CON PORTADORES DE DAI.

Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA

RTSY03 . 2015

OPCIONES DE LA TERAPIA DE RESINCRONIZACIÓN CON EL ELECTRODO QUARTET TM (QUARTET LEAD AND RESYNCHRONIZATION THERAPY OPTIONS) III.

Investigador Principal: JOAQUÍN OSCA ASENSI

CRD_789 . 2015

REGISTRO DE ESTIMULACIÓN TRANSCATÉTER CON EL SISTEMA MICRATM (MICRA)

Investigador Principal: JOAQUÍN OSCA ASENSI

ESTUDIO MICRA PM . 2017

ESTIMULACIÓN SÍNCRONA MULTIPUNTO FRENTE A ESTIMULACIÓN SECUENCIAL MULTIPUNTO DEL VENTRÍCULO IZQUIERDO PARA TRC. ESTUDIO SYNSEQ.

Investigador Principal: JOAQUÍN OSCA ASENSI

ESTUDIO SYNSEQ . 2016

APNEA DE SUEÑO, ARRITMIAS Y REMODELADO CARDIACO INVERSO EN PACIENTES CON INSUFICIENCIA CARDIACA.

Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA

ICSY03 . 2017

EVALUACIÓN CLÍNICA DEL ALGORITMO DE AUTOUMBRAL DE VENTRÍCULO IZQUIERDO.

Investigador Principal: ÓSCAR CANO PÉREZ

IPTL01 . 2017

CONTROL ESTRATÉGICO PARA LA OPTIMIZACIÓN DE LA RESPUESTA A LA TERAPIA DE RESINCRONIZACIÓN CARDÍACA (STRATEGIC MANAGEMENT TO OPTIMIZE RESPONSE TO CARDIAC RESYNCHRONIZATION THERAPY) (SMART-CRT STUDY).

Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA

C2067 . 2017

ESTUDIO NAVIGATOR EVALUACIÓN DE SEGURIDAD Y EFICACIA ELÉCTRICA DE LOS CABLES NAVIGO CON CONECTOR IS4 (SAFETY AND ELECTRICAL PERFORMANCES EVALUATION NAVIGO LEADS EQUIPPED WITH IS4 CONNECTOR).

Investigador Principal: ÓSCAR CANO PÉREZ

LCPL01 . 2017

ANTICOAGULANTES ORALES NO ANTAGONISTAS DE LA VITAMINA K EN PACIENTES CON EPISODIOS DE FRECUENCIA AURICULAR RÁPIDA.

Investigador Principal: JOAQUÍN OSCA ASENSI

NOAH-AFNET6 . 2018

REGISTRO ESPAÑOL DE CRIOABLACIÓN CON BALÓN.

Investigador Principal: ÓSCAR CANO PÉREZ

RECABA . 2018

CRIOABLACIÓN DE VENAS PULMONARES VS FÁRMACOS ANTIARRÍTMICOS EN FIBRILACIÓN AURICULAR PERSISTENTE (CRAFT).

Investigador Principal: JOAQUÍN OSCA ASENSI

CRAFT . 2018

Prevención de terapias inapropiadas y eventos adversos cardiacos y cerebrovasculares graves con un Desfibrilador Automático Implantable monocameral con detección auricular con dipolo flotante DX.

Investigador Principal: JOAQUÍN OSCA ASENSI

TRI-DX-2018-01 . 2018

EVALUACIÓN DE SEGURIDAD Y COMPORTAMIENTO ELÉCTRICO DE LAS SONDAS INVICTA EQUIPADAS CON CONECTOR DF4.

Investigador Principal: MARÍA TERESA IZQUIERDO DE FRANCISCO

LCN001 . 2019

ESTUDIO OASIS-H. ORGANIZACION ASISTENCIAL DE PACIENTES CON HOME MONITORING.

Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA

OASIS-HM . 2010

ESTUDIO ABIERTO, FASE IV, MULTICÉNTRICO, PARA EVALUAR LA EFICACIA DIAGNÓSTICA DE NUUBO NECGBAND ANTES DEL HOLTER IMPLANTABLE.

Investigador Principal: ÓSCAR CANO PÉREZ

SYN201401 . 2015

ESTUDIO DE LA EFICACIA Y LA SEGURIDAD DE F373280 EN EL MANTENIMIENTO DEL RITMO SINUSAL TRAS CARDIOVERSIÓN ELÉCTRICA EN PACIENTES CON FIBRILACIÓN AURICULAR PERSISTENTE E INSUFICIENCIA CARDÍACA CRÓNICA. INTERNACIONAL, MULTICÉNTRICO, ALEATORIZADO, DOBLE CIEG O Y CONTROLADO CON PLACEBO.

Investigador Principal: JOAQUÍN OSCA ASENSI

F373280CA201

ESTUDIO OBSERVACIONAL PARA LA EVALUACIÓN DEL MANEJO DE PACIENTES RESINCRONIZADOS CON EL ELECTRODO TETRAPOLAR QUARTETTM DE VENTRÍCULO IZQUIERDO.

Investigador Principal: JOSE OLAGUE DE ROS

CR-12-015-SP-HF

REDUCCIÓN DE CHOQUES INAPROPIADOS CON EL DISCRIMINADOR DE RITMO PARAD+.

Investigador Principal: JOSE OLAGUE DE ROS

ITSY09

EVALUACIÓN NO INVASIVA DE LA ESTIMACIÓN DEL RIESGO POST-INFARTO - EFICACIA DE UN DAI.

Investigador Principal: JOAQUÍN OSCA ASENSI

REFINE_ICD

Cita

Compartir