Effect of Dynamic Versus Stylet-Guided Intubation on First-Attempt Success in Difficult Airways Undergoing Glidescope Laryngoscopy: A Randomized Controlled Trial

Autores de IIS La Fe
Participantes ajenos a IIS La Fe
- Henao, L
- Ortega, J
- Casasempere, A
- Fernandez, Y
- Acosta, M
- Belaouchi, M
- Esparza-Minana, JM
Grupos
Abstract
BACKGROUND: Tracheal intubation failure in patients with difficult airway is still not uncommon. While videolaryngoscopes such as the Glidescope offer better glottic vision due to an acute-angled blade, this advantage does not always lead to an increased success rate because successful insertion of the tube through the vocal cords may be the limiting factor. We hypothesize that combined use of Glidescope and fiberscope used only as a dynamic guide facilitates tracheal intubation compared to a conventional Glidescope technique with a preshaped nondynamic stylet. METHODS: One hundred sixty adult patients with predicted difficult airway were randomly assigned to a conventional Glidescope (standard Glidescope group) or a combined Glidescope + fiberscope group intubation. In the Glidescope + fiberscope group under direct vision from the Glidescope, tracheal intubation was performed using the fiberscope as a guide without using fiberoptic vision, while in the standard Glidescope group, a conventional stylet-guided intubation technique was performed. We evaluated the rate of tracheal intubation success at first attempt as the primary end point (Fisher exact test). The difference between groups in airway injury, time to successful intubation, and the need for an alternative technique was also evaluated. RESULTS: First-attempt intubation success was higher in the Glidescope + fiberscope group than in the standard Glidescope group (91% vs 67%; P = .0012; fragility index, 8; absolute risk reduction, 24% [95% CI, 12%-36%]). Median time to successful tracheal intubation was shorter in the Glidescope + fiberscope group (50 vs 64 seconds; P = .035). Airway injury rate was lower in the Glidescope + fiberscope group than in the standard Glidescope group (1% vs 11%; P = .035; fragility index, 1; absolute risk reduction, 10% [95% CI, 3%-18%]). Alternative rescue technique requirements to achieve tracheal intubation were higher in the standard Glidescope group (24% vs 4%; P < .001; fragility index, 7). CONCLUSIONS: The use of a dynamic, flexible guide during a Glidescope laryngoscopy in patients with a predicted difficult airway compared to a standard intubation technique improves first-attempt intubation success, decreases the incidence of airway injury and time to successful intubation, as well as the need of an alternative technique to succeed.
Datos de la publicación
- ISSN/ISSNe:
- 0003-2999, 1526-7598
- Tipo:
- Article
- Páginas:
- 1264-1271
- Factor de Impacto:
- 1,410 SCImago ℠
- Cuartil:
- Q1 SCImago ℠
ANESTHESIA AND ANALGESIA Lippincott Williams & Wilkins Ltd.
Citas Recibidas en Web of Science: 11
Documentos
- No hay documentos
Filiaciones
Proyectos asociados
Trocar multisensor para cirugía laparoscópica con presión de pneumoperitoneo individualizada
Investigador Principal: ÓSCAR DÍAZ CAMBRONERO
INNVAL10/18/056 . AGENCIA VALENCIANA DE LA INNOVACION (AVI) . 2018
REDUCCIÓN DE LA INFECCIÓN DE HERIDA QUIRÚRGICA CON UNA ESTRATEGIA PERIOPERATORIA INDIVIDUALIZADA DE VENTILACIÓN DE PROTECCIÓN PULMONAR CON FRACCIÓN INSPIRATORIA DE OXÍGENO ELEVADA. ESTUDIO COMPARATIVO, PROSPECTIVO, MULTICÉNTRICO, ALEATORIZADO Y CONTROLADO .
Investigador Principal: ÓSCAR DÍAZ CAMBRONERO
IPROVE-O2 . 2017
MU OPIOID RECEPTOR 1 (MOR-1) EXPRESSION IN COLORECTAL CANCER AND DISEASE-FREE SURVIVAL RELATIONSHIP (MOROCCO). FIVE-YEAR FOLLOW-UP.
Investigador Principal: ÓSCAR DÍAZ CAMBRONERO
ODC-MOR-2018-01
ESTUDIO PROSPECTIVO, ALEATORIZADO, DOBLE-CIEGO, INTERNACIONAL Y MULTICÉNTRICO SOBRE LA SEGURIDAD Y LA EFICACIA DE LA SOLUCIÓN 6% HIDROXIETIL ALMIDÓN (HYDROXYETHYL STARCH) (HES) COMPARADA CON UNA SOLUCIÓN ELECTROLÍTICA EN PACIENTES SOMETIDOS A CIRUGÍA ABDOMINAL: ESTUDIO PHOENICS.
Investigador Principal: ÓSCAR DÍAZ CAMBRONERO
HC-G-H-1504 (PHOENICS) . 2018
BLOQUEO NEUROMUSCULAR RESIDUAL POSTOPERATORIO CERO (PORCZERO).
Investigador Principal: GUIDO MAZZINARI
CEO-SUG-2016-01 . 2018
POWER AUDIT, POSTOPERATIVE OUTCOMES WITHIN AN ENHANCED RECOVERY AFTER SURGERY PROTOCOL. AUDITORÍA NACIONAL DE COMPLICACIONES DESPUÉS DE LA CIRUGÍA GASTROINTESTINAL BAJA (COLORRECTAL) ELECTIVA DENTRO DE UN PROTOCOLO DE RECUPERACIÓN MEJORADA DESPUÉS DE LA CIRUGÍA.
Investigador Principal: MARÍA JOSÉ FAS VICENT
POWER AUDIT . 2018
REDUCCIÓN DE LAS COMPLICACIONES POSTOPERATORIAS Y DE LA ESTANCIA HOSPITALARIA CON UNA ESTRATEGIA PERIOPERATORIA INDIVIDUALIZADA DE VENTILACIÓN DE PROTECCIÓN PULMONAR. ESTUDIO COMPARATIVO, PROSPECTIVO, MULTICÉNTRICO, ALEATORIZADO Y CONTROLADO.
Investigador Principal: ÓSCAR DÍAZ CAMBRONERO
IPROVE . 2015
VALORACIÓN DE LA EFICACIA ANALGÉSICA DEL BLOQUEO DEL PLANO DEL MÚSCULO SERRATO (SERRATUS PLANE BLOCK) FRENTE A ANALGESIA CONVENCIONAL EN CIRUGÍA DE MAMA.
Investigador Principal: GUIDO MAZZINARI
MAZ-BUP-2015-01
GLIDESCOPE® VS GLIDESCOPE®+ASCOPE® PARA EL MANEJO DE LA VÍA AÉREA DIFÍCIL. VALORACIÓN DE UN NUEVO PROCEDIMIENTO DE INTUBACIÓN OROTRAQUEAL EN PACIENTES CON SOSPECHA DE VÍA AÉREA DIFÍCIL.
Investigador Principal: GUIDO MAZZINARI
ROV-GLI-2015-01
IMPACTO DEL BLOQUEO DEL PLANO DEL MÚSCULO SERRATO (SERRATUS PLANE BLOCK) EN EL DOLOR Y EL CONSUMO DE OPIOIDES EN CIRUGÍA DE MAMA.
Investigador Principal: GUIDO MAZZINARI
IBMS-SPB
Cita
Mazzinari G,Rovira L,Henao L,Ortega J,Casasempere A,Fernandez Y,Acosta M,Belaouchi M,Esparza JM. Effect of Dynamic Versus Stylet-Guided Intubation on First-Attempt Success in Difficult Airways Undergoing Glidescope Laryngoscopy: A Randomized Controlled Trial. Anesth Analg. 2019. 128. (6):p. 1264-1271. IF:4,305. (1).