Impact of anticoagulation therapy on outcomes in patients with cardiac implantable resynchronization devices undergoing transvenous lead extraction: A substudy of the ESC-EHRA EORP ELECTRa (European Lead Extraction ConTRolled) Registry

Autores de IIS La Fe
Participantes ajenos a IIS La Fe
- Regoli, F
- Auricchio, A
- Di Cori, A
- Segreti, L
- Blomstrom-Lunqvist, C
- Butter, C
- Deharo, JC
- Kennergren, C
- Kutarski, A
- Laroche, C
- Zalevskiy, V
- Luzzi, G
- Grabowski, M
- Rinaldi, C
- Bongiorni, MG
Grupos
Abstract
Introduction Little data are available on anticoagulation (AC) management in patients with cardiac resynchronization (CRT) devices who undergo transvenous lead extraction (TLE) procedure. We investigated the impact of AC on periprocedural complications in CRT patients undergoing TLE, enrolled in the ESC-EHRA European Lead Extraction ConTrolled (ELECTRa) registry. Methods and Results All CRT patients treated with TLE enrolled in the registry were considered. Perioperative AC management was left to the discretion of the Center. Major and minor intraprocedural and postprocedural complications were compared between patients without AC (Gp1) and patients with AC (Gp2). Regression analyses were performed to identify predictors of complications for Gp2. Out of 734 CRT pts, 328 (44.7%) were under AC (Gp2). Patients from Gp2 presented lower LVEF (Gp2 32.5 +/- 10.9 vs Gp1 34.5 +/- 11.9%; P = 0.03), more advanced heart failure disease (NYHA III/IV: Gp2 42.0 vs Gp1 31.5%; P = 0.02), and renal impairment (Gp2 39.0 vs Gp1 24.3%; P < 0.001). Perioperative regimens included AC interruption (Gp2A: n = 169, 51.5%), "bridging" (Gp2B: n = 135, 41.2%), or continued AC (Gp2C: n = 24, 7.3%). TLE complete success rates (98% in both groups) and major complication rates were comparable for both groups; minor bleeding events were more frequent in Gp2 (5.5%) compared to Gp1 (2.5%; P = 0.051). No independent predictors were identified for Gp2, but minor complications were associated with "bridging" approach (Gp2B: 16 events vs Gp2A/C: 9 events; P = 0.020). Conclusion CRT patients treated with TLE under AC were more compromised but did not present more major complications compared to patients without AC. More minor complications were associated with "bridging" AC regimen.
Datos de la publicación
- ISSN/ISSNe:
- 1045-3873, 1540-8167
- Tipo:
- Article
- Páginas:
- 1086-1095
- DOI:
- 10.1111/jce.13946
- PubMed:
- 30980441
- Factor de Impacto:
- 1,337 SCImago ℠
- Cuartil:
- Q1 SCImago ℠
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY WILEY
Citas Recibidas en Web of Science: 2
Documentos
- No hay documentos
Filiaciones
Keywords
- anticoagulation in lead extraction; CRT and lead extraction; CRT and lead management; lead extraction complications; resynchronization therapy and complications
Proyectos y Estudios Clínicos
INCORPORACIÓN GRUPOS CIBER. DR. DOLZ
Investigador Principal: LUIS VICENTE MARTÍNEZ DOLZ
CB16/11/00261 . INSTITUTO DE SALUD CARLOS III . 2017
Validación prospectiva de un índice pronóstico de muerte súbita o arritmias ventriculares malignas en adultos con cardiopatías congénitas.
Investigador Principal: TOMAS DATINO ROMANIEGA
PI17/01327 . 2018
MORE-CRT: EL AUMENTO DE LAS OPCIONES DISPONIBLES CON UN ELECTRODO VI TETRAPOLAR OFRECE SOLUCIONES CLÍNICAS A LOS PROBLEMAS DE LA TRC. MORE OPTIONS AVAILABLE WITH A QUADRIPOLAR LV LEAD PROVIDE IN CLINIC SOLUTIONS TO CRT CHALLENGES.
Investigador Principal: JOAQUÍN OSCA ASENSI
CR-11-006-HF-ID . 2012
GLORIA - AF: REGISTRO GLOBAL DEL TRATAMIENTO ANTITROMBÓTICO ORAL A LARGO PLAZO EN PACIENTES CON FIBRILACIÓN AURICULAR (FASE II/III – ESTADOS MIEMBROS DE LA UE/ AEE).
Investigador Principal: JOAQUÍN OSCA ASENSI
BOE-DAB-2012-01 . 2013
MORE RESPONSE ON CARDIAC RESYNCHRONIZATION THERAPY (CRT) WITH MULTIPOINT PACING (MPP) – MAYOR RESPUESTA A LA TERAPIA DE RESINCRONIZACIÓN CARDIACA (TRC) CON ESTIMULACIÓN MULTISITIO.
Investigador Principal: JOAQUÍN OSCA ASENSI
CR-13-006-ID-HF . 2013
ESTIMULACIÓN TRICAMERAL EN PACIENTES CON CARDIOMIOPATÍA HIPERTRÓFICA OBSTRUCTIVA. TRICHAMPION (TRIPLE CHAMBER PACING IN HOCM PATIENTS).
Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA
CR-11-030-EU-HF . 2014
INVESTIGACIÓN CLÍNICA SOBRE LAS DIFERENCIAS EN LA MAGNITUD DE LA RESPUESTA A LA TRC ENTRE HOMBRES Y MUJERES. (BIOWOMEN).
Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA
CR017 . 2015
ESTIMULACIÓN BIVENTRICULAR TRIFOCAL PARA LA OPTIMIZACIÓN DE LA TERAPIA DE RESINCRONIZACIÓN CARDIACA (TRC).
Investigador Principal: ÓSCAR CANO PÉREZ
ICSY02 . 2015
EVALUACIÓN CLÍNICA DEL PACIENTE Y FUNCIONAL DEL DISPOSITIVO EN LA PRÁCTICA CLÍNICA HABITUAL CON PORTADORES DE DAI.
Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA
RTSY03 . 2015
OPCIONES DE LA TERAPIA DE RESINCRONIZACIÓN CON EL ELECTRODO QUARTET TM (QUARTET LEAD AND RESYNCHRONIZATION THERAPY OPTIONS) III.
Investigador Principal: JOAQUÍN OSCA ASENSI
CRD_789 . 2015
REGISTRO DE ESTIMULACIÓN TRANSCATÉTER CON EL SISTEMA MICRATM (MICRA)
Investigador Principal: JOAQUÍN OSCA ASENSI
ESTUDIO MICRA PM . 2017
ESTIMULACIÓN SÍNCRONA MULTIPUNTO FRENTE A ESTIMULACIÓN SECUENCIAL MULTIPUNTO DEL VENTRÍCULO IZQUIERDO PARA TRC. ESTUDIO SYNSEQ.
Investigador Principal: JOAQUÍN OSCA ASENSI
ESTUDIO SYNSEQ . 2016
APNEA DE SUEÑO, ARRITMIAS Y REMODELADO CARDIACO INVERSO EN PACIENTES CON INSUFICIENCIA CARDIACA.
Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA
ICSY03 . 2017
EVALUACIÓN CLÍNICA DEL ALGORITMO DE AUTOUMBRAL DE VENTRÍCULO IZQUIERDO.
Investigador Principal: ÓSCAR CANO PÉREZ
IPTL01 . 2017
CONTROL ESTRATÉGICO PARA LA OPTIMIZACIÓN DE LA RESPUESTA A LA TERAPIA DE RESINCRONIZACIÓN CARDÍACA (STRATEGIC MANAGEMENT TO OPTIMIZE RESPONSE TO CARDIAC RESYNCHRONIZATION THERAPY) (SMART-CRT STUDY).
Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA
C2067 . 2017
ESTUDIO NAVIGATOR EVALUACIÓN DE SEGURIDAD Y EFICACIA ELÉCTRICA DE LOS CABLES NAVIGO CON CONECTOR IS4 (SAFETY AND ELECTRICAL PERFORMANCES EVALUATION NAVIGO LEADS EQUIPPED WITH IS4 CONNECTOR).
Investigador Principal: ÓSCAR CANO PÉREZ
LCPL01 . 2017
ANTICOAGULANTES ORALES NO ANTAGONISTAS DE LA VITAMINA K EN PACIENTES CON EPISODIOS DE FRECUENCIA AURICULAR RÁPIDA.
Investigador Principal: JOAQUÍN OSCA ASENSI
NOAH-AFNET6 . 2018
CRIOABLACIÓN DE VENAS PULMONARES VS FÁRMACOS ANTIARRÍTMICOS EN FIBRILACIÓN AURICULAR PERSISTENTE (CRAFT).
Investigador Principal: JOAQUÍN OSCA ASENSI
CRAFT . 2018
Prevención de terapias inapropiadas y eventos adversos cardiacos y cerebrovasculares graves con un Desfibrilador Automático Implantable monocameral con detección auricular con dipolo flotante DX.
Investigador Principal: JOAQUÍN OSCA ASENSI
TRI-DX-2018-01 . 2018
EVALUACIÓN DE SEGURIDAD Y COMPORTAMIENTO ELÉCTRICO DE LAS SONDAS INVICTA EQUIPADAS CON CONECTOR DF4.
Investigador Principal: MARÍA TERESA IZQUIERDO DE FRANCISCO
LCN001 . 2019
ESTUDIO OASIS-H. ORGANIZACION ASISTENCIAL DE PACIENTES CON HOME MONITORING.
Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA
OASIS-HM . 2010
ESTUDIO ABIERTO, FASE IV, MULTICÉNTRICO, PARA EVALUAR LA EFICACIA DIAGNÓSTICA DE NUUBO NECGBAND ANTES DEL HOLTER IMPLANTABLE.
Investigador Principal: ÓSCAR CANO PÉREZ
SYN201401 . 2015
ESTUDIO DE LA EFICACIA Y LA SEGURIDAD DE F373280 EN EL MANTENIMIENTO DEL RITMO SINUSAL TRAS CARDIOVERSIÓN ELÉCTRICA EN PACIENTES CON FIBRILACIÓN AURICULAR PERSISTENTE E INSUFICIENCIA CARDÍACA CRÓNICA. INTERNACIONAL, MULTICÉNTRICO, ALEATORIZADO, DOBLE CIEG O Y CONTROLADO CON PLACEBO.
Investigador Principal: JOAQUÍN OSCA ASENSI
F373280CA201
ESTUDIO OBSERVACIONAL PARA LA EVALUACIÓN DEL MANEJO DE PACIENTES RESINCRONIZADOS CON EL ELECTRODO TETRAPOLAR QUARTETTM DE VENTRÍCULO IZQUIERDO.
Investigador Principal: JOSE OLAGUE DE ROS
CR-12-015-SP-HF
REDUCCIÓN DE CHOQUES INAPROPIADOS CON EL DISCRIMINADOR DE RITMO PARAD+.
Investigador Principal: JOSE OLAGUE DE ROS
ITSY09
EVALUACIÓN NO INVASIVA DE LA ESTIMACIÓN DEL RIESGO POST-INFARTO - EFICACIA DE UN DAI.
Investigador Principal: JOAQUÍN OSCA ASENSI
REFINE_ICD
Cita
Regoli F,Auricchio A,Di A,Segreti L,Blomstrom C,Butter C,Deharo JC,Kennergren C,Kutarski A,Laroche C,Zalevskiy V,Luzzi G,CANO O,Grabowski M,Rinaldi C,Bongiorni MG. Impact of anticoagulation therapy on outcomes in patients with cardiac implantable resynchronization devices undergoing transvenous lead extraction: A substudy of the ESC-EHRA EORP ELECTRa (European Lead Extraction ConTRolled) Registry. J Cardiovasc Electrophysiol. 2019. 30. (7):p. 1086-1095. IF:2,424. (2).