Magnetic resonance imaging as an assessment tool following intervention with an AdVance XP suburethral sling for postprostatectomy urinary incontinence
Autores de IIS La Fe
Participantes ajenos a IIS La Fe
- Serra, AC
- Gomez, PP
- Martin, I
- Dominguez-Escrig, J
- Barrios, M
- Deval, JC
- Rubio-Briones, J
Grupos
Abstract
Aims The aim of this study was to compare magnetic resonance imaging (MRI) parameters in patients with mild incontinence after radical prostatectomy, who had undergone treatment with a suburethral sling. The objective was to compare patients who had been successfully treated with unsuccessful patients. Methods This observational cohort study at a single institution evaluated consecutive patients treated with an AdVance XP sling. MRI was performed using a 1.5 Tesla system. Preoperative urodynamic assessment and flexible cystoscopy were performed. The qualitative analysis was based on sling indentation (complete vs incomplete). The quantitative analysis comprised the following three parameters: the sling-pubis distance, the thickness of the proximal urethral bulb, and the sling backward distance (SBD), defined as the distance between the prolongation of a line through the major axis of the pubis (the line-segment joining the vertices of the pubis) and the sling indentation. The primary outcome was pad count at 3 months; cure as zero pads. A logistic univariate regression model was employed to assess the potential predictors of successful outcomes. An adjusted multivariate logistic regression model using the significant univariate factors was developed. Results Of the 83 patients enrolled, the univariate analysis revealed a relationship between failure and adverse urodynamics and between success and sling indentation, thickness of the proximal bulb and SBD. Only the association with SBD persisted in the multivariate analysis. Conclusions MRI revealed a strong relationship between proper positioning of the sling (small SBD) and continence outcome. These data have important implications for a second surgery following initial sling failure.
Datos de la publicación
- ISSN/ISSNe:
- 0733-2467, 1520-6777
- Tipo:
- Article
- Páginas:
- 1616-1624
- DOI:
- 10.1002/nau.24023
- PubMed:
- 31090095
- Factor de Impacto:
- 0,963 SCImago ℠
- Cuartil:
- Q1 SCImago ℠
NEUROUROLOGY AND URODYNAMICS WILEY
Citas Recibidas en Web of Science: 3
Documentos
- No hay documentos
Filiaciones
Keywords
- magnetic resonance imaging; male; prostatectomy; stress urinary incontinence; suburethral slings; urethra
Cita
Serra AC,Gomez PP,Martin I,Dominguez J,ALBERICH A,Barrios M,Deval JC,Rubio J. Magnetic resonance imaging as an assessment tool following intervention with an AdVance XP suburethral sling for postprostatectomy urinary incontinence. Neurourol. Urodyn. 2019. 38. (6):p. 1616-1624. IF:2,037. (3).
Portal de investigación