Spanish Pacemaker Registry. 15th Official Report of the Spanish Society of Cardiology Working Group on Cardiac Pacing (2017)

Fecha de publicación:

Autores de IIS La Fe

Participantes ajenos a IIS La Fe

  • Jimenez, MP
  • Carreno, DL
  • Garcia, JC

Grupos

Abstract

Introduction and objectives: This report describes the data reported to the Spanish Pacemaker Registry concerning the activity in cardiac pacing in 2017 in Spain. Methods: The analysis is based on the data obtained from the European Pacemaker Identification Card and the information reported by supplier companies related to global number of implanted pacemakers. Results: Information was received from 106 hospitals, with a total of 12672 cards, representing the 32.1% of the total pacing activity. Conventional pacemaker and resynchronization pacemaker rate was 820 units/million and 26 units/million inhabitants respectively. A total of 333 leadless pacemakers were implanted. The mean age was 77.9 years, predominantly men (58.5%). Most electrodes were bipolar, with active fixation and only 20% had magnetic resonance protection. Atrioventricular block was the most common electrocardiographic disturb. Most patients received bicameral sequential pacing although single chamber VVIR pacing was used in up to 21.8% of patients. Patients older than 80 years benefited less from physiological pacing and resynchronization therapy. Conclusions: Total use of pacemaker generators remains stable with respect to 2016. Age is the main factor that influences pacing mode selection, which could be improved in around 22% of patients. Leadless pacing continues to rise. (C) 2018 Sociedad Espanola de Cardiologia. Published by Elsevier Espana, S.L.U. All rights reserved.

Datos de la publicación

ISSN/ISSNe:
0300-8932, 1579-2242

REVISTA ESPANOLA DE CARDIOLOGIA  EDICIONES DOYMA S A

Tipo:
Article
Páginas:
1059-1068
Factor de Impacto:
0,579 SCImago
Cuartil:
Q2 SCImago

Citas Recibidas en Web of Science: 10

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Permanent cardiac pacing; Pacemaker leads; Biventricular pacing; Registry

Campos de estudio

Proyectos asociados

INCORPORACIÓN GRUPOS CIBER. DR. DOLZ

Investigador Principal: LUIS VICENTE MARTÍNEZ DOLZ

CB16/11/00261 . INSTITUTO DE SALUD CARLOS III . 2017

Validación prospectiva de un índice pronóstico de muerte súbita o arritmias ventriculares malignas en adultos con cardiopatías congénitas.

Investigador Principal: TOMAS DATINO ROMANIEGA

PI17/01327 . 2018

MORE-CRT: EL AUMENTO DE LAS OPCIONES DISPONIBLES CON UN ELECTRODO VI TETRAPOLAR OFRECE SOLUCIONES CLÍNICAS A LOS PROBLEMAS DE LA TRC. MORE OPTIONS AVAILABLE WITH A QUADRIPOLAR LV LEAD PROVIDE IN CLINIC SOLUTIONS TO CRT CHALLENGES.

Investigador Principal: JOAQUÍN OSCA ASENSI

CR-11-006-HF-ID . 2012

GLORIA - AF: REGISTRO GLOBAL DEL TRATAMIENTO ANTITROMBÓTICO ORAL A LARGO PLAZO EN PACIENTES CON FIBRILACIÓN AURICULAR (FASE II/III – ESTADOS MIEMBROS DE LA UE/ AEE).

Investigador Principal: JOAQUÍN OSCA ASENSI

BOE-DAB-2012-01 . 2013

MORE RESPONSE ON CARDIAC RESYNCHRONIZATION THERAPY (CRT) WITH MULTIPOINT PACING (MPP) – MAYOR RESPUESTA A LA TERAPIA DE RESINCRONIZACIÓN CARDIACA (TRC) CON ESTIMULACIÓN MULTISITIO.

Investigador Principal: JOAQUÍN OSCA ASENSI

CR-13-006-ID-HF . 2013

ESTIMULACIÓN TRICAMERAL EN PACIENTES CON CARDIOMIOPATÍA HIPERTRÓFICA OBSTRUCTIVA. TRICHAMPION (TRIPLE CHAMBER PACING IN HOCM PATIENTS).

Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA

CR-11-030-EU-HF . 2014

INVESTIGACIÓN CLÍNICA SOBRE LAS DIFERENCIAS EN LA MAGNITUD DE LA RESPUESTA A LA TRC ENTRE HOMBRES Y MUJERES. (BIOWOMEN).

Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA

CR017 . 2015

ESTIMULACIÓN BIVENTRICULAR TRIFOCAL PARA LA OPTIMIZACIÓN DE LA TERAPIA DE RESINCRONIZACIÓN CARDIACA (TRC).

Investigador Principal: ÓSCAR CANO PÉREZ

ICSY02 . 2015

EVALUACIÓN CLÍNICA DEL PACIENTE Y FUNCIONAL DEL DISPOSITIVO EN LA PRÁCTICA CLÍNICA HABITUAL CON PORTADORES DE DAI.

Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA

RTSY03 . 2015

OPCIONES DE LA TERAPIA DE RESINCRONIZACIÓN CON EL ELECTRODO QUARTET TM (QUARTET LEAD AND RESYNCHRONIZATION THERAPY OPTIONS) III.

Investigador Principal: JOAQUÍN OSCA ASENSI

CRD_789 . 2015

REGISTRO DE ESTIMULACIÓN TRANSCATÉTER CON EL SISTEMA MICRATM (MICRA)

Investigador Principal: JOAQUÍN OSCA ASENSI

ESTUDIO MICRA PM . 2017

ESTIMULACIÓN SÍNCRONA MULTIPUNTO FRENTE A ESTIMULACIÓN SECUENCIAL MULTIPUNTO DEL VENTRÍCULO IZQUIERDO PARA TRC. ESTUDIO SYNSEQ.

Investigador Principal: JOAQUÍN OSCA ASENSI

ESTUDIO SYNSEQ . 2016

APNEA DE SUEÑO, ARRITMIAS Y REMODELADO CARDIACO INVERSO EN PACIENTES CON INSUFICIENCIA CARDIACA.

Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA

ICSY03 . 2017

EVALUACIÓN CLÍNICA DEL ALGORITMO DE AUTOUMBRAL DE VENTRÍCULO IZQUIERDO.

Investigador Principal: ÓSCAR CANO PÉREZ

IPTL01 . 2017

CONTROL ESTRATÉGICO PARA LA OPTIMIZACIÓN DE LA RESPUESTA A LA TERAPIA DE RESINCRONIZACIÓN CARDÍACA (STRATEGIC MANAGEMENT TO OPTIMIZE RESPONSE TO CARDIAC RESYNCHRONIZATION THERAPY) (SMART-CRT STUDY).

Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA

C2067 . 2017

ESTUDIO NAVIGATOR EVALUACIÓN DE SEGURIDAD Y EFICACIA ELÉCTRICA DE LOS CABLES NAVIGO CON CONECTOR IS4 (SAFETY AND ELECTRICAL PERFORMANCES EVALUATION NAVIGO LEADS EQUIPPED WITH IS4 CONNECTOR).

Investigador Principal: ÓSCAR CANO PÉREZ

LCPL01 . 2017

ANTICOAGULANTES ORALES NO ANTAGONISTAS DE LA VITAMINA K EN PACIENTES CON EPISODIOS DE FRECUENCIA AURICULAR RÁPIDA.

Investigador Principal: JOAQUÍN OSCA ASENSI

NOAH-AFNET6 . 2018

REGISTRO ESPAÑOL DE CRIOABLACIÓN CON BALÓN.

Investigador Principal: ÓSCAR CANO PÉREZ

RECABA . 2018

CRIOABLACIÓN DE VENAS PULMONARES VS FÁRMACOS ANTIARRÍTMICOS EN FIBRILACIÓN AURICULAR PERSISTENTE (CRAFT).

Investigador Principal: JOAQUÍN OSCA ASENSI

CRAFT . 2018

Prevención de terapias inapropiadas y eventos adversos cardiacos y cerebrovasculares graves con un Desfibrilador Automático Implantable monocameral con detección auricular con dipolo flotante DX.

Investigador Principal: JOAQUÍN OSCA ASENSI

TRI-DX-2018-01 . 2018

EVALUACIÓN DE SEGURIDAD Y COMPORTAMIENTO ELÉCTRICO DE LAS SONDAS INVICTA EQUIPADAS CON CONECTOR DF4.

Investigador Principal: MARÍA TERESA IZQUIERDO DE FRANCISCO

LCN001 . 2019

ESTUDIO OASIS-H. ORGANIZACION ASISTENCIAL DE PACIENTES CON HOME MONITORING.

Investigador Principal: MARÍA JOSÉ SANCHO-TELLO DE CARRANZA

OASIS-HM . 2010

ESTUDIO ABIERTO, FASE IV, MULTICÉNTRICO, PARA EVALUAR LA EFICACIA DIAGNÓSTICA DE NUUBO NECGBAND ANTES DEL HOLTER IMPLANTABLE.

Investigador Principal: ÓSCAR CANO PÉREZ

SYN201401 . 2015

ESTUDIO DE LA EFICACIA Y LA SEGURIDAD DE F373280 EN EL MANTENIMIENTO DEL RITMO SINUSAL TRAS CARDIOVERSIÓN ELÉCTRICA EN PACIENTES CON FIBRILACIÓN AURICULAR PERSISTENTE E INSUFICIENCIA CARDÍACA CRÓNICA. INTERNACIONAL, MULTICÉNTRICO, ALEATORIZADO, DOBLE CIEG O Y CONTROLADO CON PLACEBO.

Investigador Principal: JOAQUÍN OSCA ASENSI

F373280CA201

ESTUDIO OBSERVACIONAL PARA LA EVALUACIÓN DEL MANEJO DE PACIENTES RESINCRONIZADOS CON EL ELECTRODO TETRAPOLAR QUARTETTM DE VENTRÍCULO IZQUIERDO.

Investigador Principal: JOSE OLAGUE DE ROS

CR-12-015-SP-HF

REDUCCIÓN DE CHOQUES INAPROPIADOS CON EL DISCRIMINADOR DE RITMO PARAD+.

Investigador Principal: JOSE OLAGUE DE ROS

ITSY09

EVALUACIÓN NO INVASIVA DE LA ESTIMACIÓN DEL RIESGO POST-INFARTO - EFICACIA DE UN DAI.

Investigador Principal: JOAQUÍN OSCA ASENSI

REFINE_ICD

Cita

Compartir