Conduction system vs. biventricular pacing in heart failure with reduced ejection fraction: a meta-analysis of randomized controlled trials
Fecha de publicación:
Autores de IIS La Fe
Participantes ajenos a IIS La Fe
- Karakasis P.
- Vlachos K.
- Siontis K.C.
- Tzeis S.
- Strik M.
- Pamporis K.
- Leventopoulos G.
- Antoniadis A.P.
- Jaïs P.
- Burri H.
- Fragakis N.
Grupos
Abstract
Aims: Conduction system pacing (CSP) has emerged as a physiologic alternative to cardiac resynchronization therapy (CRT) with biventricular pacing (BiVP) in heart failure with reduced ejection fraction (HFrEF), yet its comparative effects remain uncertain. This meta-analysis sought to compare outcomes of CSP vs. BiVP in patients with HFrEF undergoing CRT. Methods and results: MEDLINE, Embase, Scopus, and the Cochrane Database were searched through 4 May 2026. Randomized controlled trials (RCTs) were synthesized using random-effects meta-analysis. Thirteen RCTs including 1320 participants were analysed (657 CSP, 663 BiVP). Conduction system pacing was associated with a lower risk of the composite of hospitalization for heart failure (HHF) or all-cause mortality compared with BiVP (46 vs. 83 events; odds ratio [OR] 0.51, 95% confidence interval [CI] 0.28–0.93). No significant differences were observed for HHF alone (OR 0.68, 95% CI 0.36–1.27) or all-cause mortality (OR 0.75, 95% CI 0.36–1.58). Conduction system pacing was associated with greater improvement in the 6-min walk distance (mean difference [MD] 21.53 m, 95% CI 4.33–38.73) and New York Heart Association functional class (standardized mean difference [SMD] -0.27, 95% CI -0.47 to -0.07), but not quality of life. Conduction system pacing also reduced QRS duration compared with BiVP (MD -10.94 ms, 95% CI -17.55 to -4.34), with no significant differences in left ventricular ejection fraction, left ventricular end-systolic volume, overall pacing threshold, total procedure time, fluoroscopy time, any complication, or reintervention. Conclusion: In patients with HFrEF undergoing CRT, CSP is associated with lower composite risk of HHF or all-cause mortality compared with BiVP. Conduction system pacing is also associated with improved functional capacity, without significant differences in safety or procedural outcomes. © The Author(s) 2026. Published by Oxford University Press on behalf of the European Society of Cardiology. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
Datos de la publicación
- ISSN/ISSNe:
- 1099-5129, 1532-2092
- Tipo:
- Review
- Páginas:
- -
- PubMed:
- 42586561
- Enlace a otro recurso:
- www.scopus.com
- Factor de Impacto:
- 1,957 SCImago ℠
- Cuartil:
- Q1 SCImago ℠
EUROPACE OXFORD UNIV PRESS
Citas Recibidas en Web of Science: 1
Citas Recibidas en Scopus: 1
Documentos
- No hay documentos
Filiaciones
Keywords
- Cardiac Pacing, Artificial; Cardiac Resynchronization Therapy; Heart Conduction System; Heart Failure; Humans; Randomized Controlled Trials as Topic; Stroke Volume; Treatment Outcome; Ventricular Function, Left; cardiac resynchronization therapy; heart failure; heart left ventricle function; heart muscle conduction system; heart pacing; heart stroke volume; human; meta analysis; mortality; pathophysiology; procedures; randomized controlled trial (topic); therapy; treatment outcome
Cita
Karakasis P,Vlachos K,Siontis KC,Cano Ó,Tzeis S,Strik M,Pamporis K,Leventopoulos G,Antoniadis AP,Jaïs P,Burri H,Fragakis N. Conduction system vs. biventricular pacing in heart failure with reduced ejection fraction: a meta-analysis of randomized controlled trials. Europace. 2026. 28(8):euag170. IF:10,200. (1).
Portal de investigación