Boussignac continuous positive airway pressure device during inter-hospital transportation in infants aged less than three months
Fecha de publicación:
Autores de IIS La Fe
Participantes ajenos a IIS La Fe
- de la Cuesta, RMR
- Guerra, PD
- Norniella, CM
- Izquierdo, FB
- Garcia, JG
- Villanueva, AM
Abstract
Background. The present study aims to evaluate the safety and effectiveness of the Boussignac continuous positive airway pressure device (CPAPB) when used during the transportation of infants under three months of age with bronchiolitis. Methods. Transversal analytical observational study of four years duration. Data was collected on 25 infants who needed inter-hospital transportation to the reference Paediatric Intensive Care Unit (PICU), with CPAPB and Helmet interface. The epidemiological characteristics of the transportation and evolution in the PICU were registered, as well as the cardiorespiratory gastronomic parameters prior to transfer and on arrival at the PICU. Results. The median level of continuous airway pressure (CPAP) used during the transfer was 7 cm H2O (6-7.25). No patient required endotracheal intubation during transportation, while one patient required this during the first six hours of admission in the PICU. The following cardiorespiratory parameters presented a statistically significant improvement on arrival at the PICU: modified Wood-Downes score [8.40 (2.1) vs 5.29 (1.68)], respiratory frequency [60.72 (12.73) vs 47.28 (10.31)], cardiac frequency [167.28 (22.60) vs 154.48 (24.83)] and oxygen saturation [92.08 (5.63) vs 97.64 (2.27)]. Conclusions. Application of CPAPB proved to be a safe method of respiratory support in infants under three months of age. Its use during transportation brought an improvement in cardiorespiratory parameters.
Datos de la publicación
- ISSN/ISSNe:
- 1137-6627, 2340-3527
- Tipo:
- Article
- Páginas:
- 49-54
- DOI:
- 10.23938/ASSN.0587
- PubMed:
- 30895967
- Factor de Impacto:
- 0,206 SCImago ℠
- Cuartil:
- Q3 SCImago ℠
Anales del Sistema Sanitario De Navarra GOBIERNO DE NAVARRA
Documentos
- No hay documentos
Filiaciones
Keywords
- Positive airway pressure; Transportation; Bronchiolitis; Infant
Cita
de la Cuesta RMR,Guerra PD,Norniella CM,Izquierdo FB,Garcia JG,Villanueva AM,ALAPORT VM. Boussignac continuous positive airway pressure device during inter-hospital transportation in infants aged less than three months. An. Sist. Sanit. Navar. 2019. 42. (1):p. 49-54. IF:0,829. (4).
Portal de investigación